Setup Guide IP Link® T: or RTAN om f IMPO .extron.c e and www user guid ns r to Refe mplete nstructio o c ni the llatio insta IPL T Series IP Link Ethernet Control Interfaces (IPL T S Series, IPL T SFI244, IPL T CR48) 68-1377-01 Rev.
Safety Instructions • English Warning This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. Power sources • This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
安全须知 • 中文 这个符号提示用户该设备用户手册中有重要的 操作和维护说明。 这个符号警告用户该设备机壳内有暴露的危险 电压,有触电危险。 注意 阅读说明书 • 用户使用该设备前必须阅读并理解所有安全 和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使用。 遵守警告 • 用户应遵守产品和用户指南上的所有安全和操 作说明。 避免追加 • 不要使用该产品厂商没有推荐的工具或追加设 备,以避免危险。 警告 电源 • 该设备只能使用产品上标明的电源。 设备必须使用有地线 的供电系统供电。 第三条线(地线)是安全设施,不能不用或 跳过 。 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后或桌面电源 的电源线,或任何接到市电系统的电源线。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没有用户可 以更换的零件。为避免出现触电危险不要自己试图打开设备盖子 维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止机内敏感元 件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。必须使用与厂家推荐的 相同
Contents Introduction........................................1 About this Guide .................................1 IPL T Series Products ...........................1 IPL T S Series ....................................1 IPL T SFI244 ......................................4 IPL T CR48 ........................................4 Global Configurator ...........................5 System Requirements .....................7 Installing Global Configurator .......7 Setup.................................................
vi IPL T Series • Contents
Introduction This section gives an overview of the setup guide and describes the IPL T Series IP Link® Ethernet Control Interfaces and the features of these products. Topics that are covered include: zz About this Guide zz IPL T Series Products zz Global Configurator About this Guide This setup guide describes the function, installation, and configuration of the IPL T Series Ethernet Control Interfaces. Within this guide, the term "IPL T controller" refers to products in the IPL T Series.
IPL T S2 Features of the IPL T S2 include: zz 12 VDC, 1 A desktop power supply zz RJ-45 Ethernet receptacle zz Two (2) 9-pin D RS-232, RS-422, or RS-485 serial ports - or Two (2) 3.
Lighting Control Extron IPL T S4 M 3 CO M 1 M 2 05 2 CO CO 2 CO 12 30 D# M Ethernet Control Interface with GlobalViewero software 09 UI RS-232 N LA WER PO ptop V X 12 MA .5A La D DV AY PL R DISWE PO R VC 6 ME LU TCP/IP Network MLC 20 VO X MA MIN RS-232 Ethernet Ex n tro Extron MLC 206 MediaLinko Controller Remote User Control & Administrator Monitoring Projector Laptop DVD VCR Figure 1.
IPL T SFI244 Features of the IPL T SFI244 include: zz 12 VDC, 1 A desktop power supply zz RJ-45 Ethernet receptacle zz Two (2) RS-232 serial ports zz Four (4) flex I/O ports zz Four (4) I/R ports zz Six (6) Ethernet control ports Motion Detector Projector RS-232 Y4 LA Y3 LA Y2 LA NO Extron IPL T RLY4 Relay box Extron IPL T SFI244 Ethernet Control Interface IR M2 CO N LA V X 12 MA .
Screen Control Projector Lift Control Blinds Projector 4 3 2 1 8 7 6 T PU 5 IN Extron IPL T CR48 Ethernet Control Interface GlobalViewer® 1 2 3 4 N LA WER PO V 12 0.5A TCP/IP Network Lighting System A/V Resource Management and Remote Control Application Figure 3.
Figure 4. Global Configurator Application Screen Using GC you can configure a single room controller or create a Web-based remote monitoring system for hundreds of A/V devices in multiple locations. You can configure an IPL T controller using GC without having the device physically connected to the A/V network. CAUTION: NOTE: 6 Use Global Configurator version 3.0 or later. Update all PCs and devices running earlier versions of GC. Ethernet driver support requires Global Configurator 3.
System Requirements The miminum system requirements for the PC on which you install Global Configurator include: zz Intel® Pentium® III, 1 GHz processor zz Microsoft® Windows® XP SP2, Windows Vista®, or Windows 7 zz Microsoft Internet Explorer® 6.0 with ActiveX® enabled NOTE: If ActiveX is not enabled, you may get a prompt from the browser or you will see the "Please wait while the files are loading..." message in the GlobalViewer control page. zz Microsoft Windows Script 5.
To install Global Configurator from an Extron Software Products Disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. From the Windows desktop, open My Computer and select the appropriate disk drive. 3. Double-click launch.exe. 4. Wait for the Extron Software Products page to load. 5. Click on the Software icon. 6. Scroll down to the Global Configurator description and click the Install link in the far right column. 7.
Setup This section describes the hardware setup and configuration of the IPL T Series controllers. Topics that are covered include: zz Front Panel Features zz Rear Panel Features zz Resetting the Controller zz Connections and Wiring zz Configuring for Network Communication zz Configuring the IPL T Series with Global Configurator Front Panel Features IPL T S Series a Power LED — A green LED COM lights to indicate that the unit is receiving power.
e LINK LED — A green LED IPL T S6 R f ACT LED — A yellow LED lights to indicate that data is being sent or received. 1 100 RX TX TX RX COM CTS RX RTS COM TX lights to indicate that the unit is connected to an active network. 1 3 5 LINK 2 4 6 ACT 2 3 3 3 IPL T SFI244 IPL T SFI244 I/O COM TX R RX 1 IR 3 1 3 ACT 2 2 1 3 2 100 LINK 1 4 4 5 2 4 7 8 9 6 a Power LED — A green LED lights to indicate that the unit is receiving power.
IPL T CR48 IPL T CR48 INPUT R 1 3 2 1 2 4 3 RELAY 1 2 3 5 4 6 100 5 LINK 6 ACT 7 7 8 4 a Power LED — A green LED lights to indicate that the unit is receiving power. b Reset button — Recessed multiple function Reset button. See Resetting the Controller for more information. c Input LEDs — A green LED lights to indicate that the port is active. d Relay LEDs — A green LED lights to indicate that the relay is closed and activated.
serial port 4 h MAC address — The unique hardware ID number (MAC address) of the unit (for example, 00-05-A6-00-00-01) IPL T S6 4 6 COM1 MAC: 00-05-A6-XX-XX-XX S/N: POWER LAN COM3 12V .5A MAX TX RX 1 IPL T SFI244 4 8 g COM4 — 9-pin D connector for 2 COM5 COM4 TX RX TX RX 3 COM6 COM2 TX RX 5 5 IPL T SFI244 MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .
Resetting the Controller There are five reset modes (numbered 1, 2, 3, 4, 5 for the sake of comparison with other Extron IPL products) available by using the Reset button (b) on the front panel. The Reset button is recessed, so use of a pointed stylus, ballpoint pen, or Extron Tweeker is suggested. CAUTION: NOTE: Review the reset modes carefully. Use of the wrong reset mode may result in unintended loss of flash memory programming, reassignment of ports, or a unit reboot.
Connections and Wiring Power Connection To connect the power supply: 1. Insert the 2-pole captive screw connector into the power supply receptacle on the rear panel of the controller. A Ridges Smooth SECTION A–A A 3/16” (5 mm) Max. Power Supply Output Cord MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .
Crossover Cable Pins: 12345678 Pin Insert Twisted Pair Wires End 1 Wire color End 1 Wire color Pin End 2 Wire color 1 White-green White-orange 1 White-orange White-orange 2 Green Orange 2 Orange 3 White-orange White-green 3 White-green White-green 4 Blue Blue 4 Blue Blue 5 White-blue White-blue 5 White-blue White-blue 6 Orange Green 6 Green 7 White-brown White-brown 7 White-brown White-brown 8 Brown Brown 8 Brown Brown T568A RJ-45 Connector Straight-through Cable E
Captive screw connector The IPL T S2, IPL T S6, and IPL T SFI244 have COM ports with captive screw connectors. The two COM ports with captive screw connectors on the IPL T S2 are common to the two 9-pin D connectors. Only one connector can be used for each COM port. If you use a COM port captive screw connector, its 9-pin D port is not accessible. The IPL T S6 has four COM ports with captive screw connectors that are independent of COM ports 1 and 2, which have 9-pin D connectors.
IR Ports The IPL T SFI244 has four IR ports for infrared device connection. You can connect IR emitters or a wired IR control port of another device to send IR signals (with or without carrier frequencies) to display or source devices. See the diagram below for IR port wiring. 1 IR 2 IPL T SFI244 Rear Panel IR Output Ground ( ) S G S G To Projector, Panel Display, or Source Device’s Wired IR Remote Port or IR emitter Figure 11.
Flex I/O Ports The IPL T SFI244 has four Flex I/O ports that can be configured as digital inputs, digital outputs, or analog inputs. When configured as digital inputs, the Flex I/O ports can connect to switches and sensors. When configured as digital outputs, the Flex I/O ports can drive devices that accept a TTL input signal. When configured as analog inputs, these Flex I/O ports can receive analog voltages for use with photo sensors, level feedback, and other devices.
Then, you must change the default settings of the controller (IP address, subnet mask, and [optional] administrator name and password) in order to use the controller on an intranet (LAN) or on the Internet. After you have set up the IPL T controller for network communication, you can reset the PC to its original network configuration. NOTE: Both the computer and the IPL T controller must be connected to the same subnet on a LAN (using a straight-through cable).
5. Execute a ping command by typing ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.170.15 After issuing this command, the controller changes to the new address and starts responding to the ping requests, as described. You must ping the IPL T controller in order for the IP address change to take place. Figure 15. Controller Response to a Ping Request You can reconnect using either Telnet or a Web browser to verify that the update was successful. 6.
IPL T Series • Setup 21
Extron® Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase.
Setup Guide Checklist Install Global Configurator. zz Download from www.extron.com - or zz Install from Extron Software Products Disk Make the necessary IPL T Series cable connections. Power Local Area Network (LAN) A/V devices Create a Global Configurator (GC) project file. Add and configure the IPL T Series controller and other devices. Build and upload the GC project file. Launch the GlobalViewer® interface. Refer to the Global Configurator Help file for these procedures. Download device drivers.