MSDS
Page 1 of 7
GHS
SAFETY DATA SHEET
I. PRODUCT IDENTIFICATION
MANUFACTURER/SUPPLIER
Exide Technologies
13000 Deerfield Parkway, Bldg. 200
Milton, GA 30004
CHEMICAL/TRADE NAME Lead-Acid Battery
(as used on label)
PRODUCT ID UN2794
FOR FURTHER INFORMATION
Primary Contact:
Exide SDS Support (770) 421-3485
Secondary Contact:
Joe Bolea (423) 989-6377
Fred Ganster (610) 921-4052
CHEMICAL FAMILY/ Electric Storage Battery
CLASSIFICATION
FOR EMERGENCY
CHEMTREC (800) 424-9300
(703) 527-3887 – Collect
24-hour Emergency Response Contact
Ask for Environmental Coordinator
II. HAZARD IDENTIFICATION
Signal Word: Danger
Category: GHS Codes Description
Health: STOT RE 2
Acute Tox. 4
Repr. 1A
Skin Corr. 1A
Flam. Gas 1
Carc. 1A (arsenic)
Aquatic Chronic 1
Aquatic Acute 1
H302
H314
H332
H350
H360
H373
H220
H410
P260
P308+313
P301/330/331
P303/361/353
P304/340
P305/351/338
P310
Harmful if swallowed.
Causes severe skin burns and eye damage.
Harmful if inhaled.
May cause cancer by ingestion
May damage fertility or the unborn child.
May cause damage to organs through prolonged or repeated exposure.
Extremely flammable gas (hydrogen)
Very toxic to aquatic life with long lasting effects.
Do not breathe dust/fume/gas/mist/vapors/spray.
If exposed/concerned, seek medical attention/advice.
IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
IF ON SKIN (or hair): Remove/Take off immediately all
contaminated clothing. Rinse skin with water/shower.
IF INHALED: Remove victim to fresh air and keep at rest in a
position comfortable for breathing.
IF IN EYES: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTER or doctor/physician.
Handling:
P210
P260
P264
P280
P403
P405
P391
P273
P501
Keep away from heat/sparks/open flames/hot surfaces. No smoking
Do not breathe dust/fume/gas/mist/vapors/spray
Wash thoroughly after handling.
Wear protective gloves/protective clothing/eye protection/face
protection.
Store in well-ventilated area
Store locked up.
Collect spillage
Avoid release to the environment
Dispose of contents/container in accordance with
local/regional/national/international regulation.
WARNING: Batteries subjected to abusive charging at excessively high currents for prolonged periods of time without vent caps in place
may create a surrounding atmosphere of the offensive strong inorganic acid mist containing sulfuric acid.
Reactivity:
Highly reactive with water and alkalis