INSTRUCTION MANUAL EDSR-900 9 Channel Duplex Digital Video Recorder EDSR-1600 16 Channel Duplex Digital Video Recorder V1.
Safety Precautions CAUTION DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. WARNING TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE . Safety Precautions Refer all work related to the installation of this product to qualified service personnel or system installers. Do not block the ventilation opening or slots on the cover. Do not drop metallic parts through slots.This could permanently damage the appliance.
Safety Precautions Safety Precautions The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated ”dangerous voltage”within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance(servicing)instructions in the literature accompanying the appli
Important Safeguards Important Safeguards Read Instruction---All the safety and operating instructions should be read before the init is operated Retain Instructions---The safety and operating instructions should be retained for future reference. Heed Warnings— All warnings on the unit and in the operating instructions should be adhered to. Follow Instructions— All operating and use instructions should be followed Cleaning— Unplug the unit from the outlet before cleaning.
Table of Contents 1. Product Overview… … … … … … … … … … … … … … .… … … … … … ..… ..… .. ............ Page 1 1.1 Main features… … … … … … … … … … … … … … … … … … … … … … … … … .....… ..… … … 1 1.2 Specifications… … … … … … … … … … … … … … … … … … … … … … … … ..… … … … … … . 2 2. Back panel connections… … … … … … … … … … … … … … … … … ......… … … ................ 3~4 3. System connection… … … … … … … … … … .… … … … … … … … … … … … … … .......… … … . 5 Before installation… … ..
Product Overview 1. Product Overview The EDSR-900 / EDSR1600 Duplex Digital Video Recorder (DVR) a full-featured DVR designed specifically for use in security industry. The DVR incorporates all the benefits of digital video recording, is simple to install, and operates just like a VCR. Highly efficient compression technology and superior resolution of recorded images make the DVR stand out from the competition as the best choice for security surveillance.
Specifications 1.
Back Panel Connections 2. Back Panel Connections 6 5 1 2 3 4 EDSR-900 7 9 8 11 10 14 13 12 3 6 5 4 2 1 EDSR-1600 7 8 9 10 11 13 12 14 1 ON/OFF: Main on/off switch. 2 AC100~240V power socket. 3 Matrix Outputs: These connectors are used for additional 4 programmable Call monitors. With these outputs, there are totally 4 Matrix out monitors. These monitors can only display full screen as regular call monitor.
Back Panel Connections 10 ALARM I/O: (Refer pin assignment in Appendix-C, Page 44) ALM-INPUT : Normally Open (N.O) or Normally Close (N.C) type alarm sensor input. The Alarm Input can be selected as N.O or N.C input in the setup menu. When an alarm occurs, alarm recording will automatically start. ALM-OUTPUT : Two-way contact relay alarm output. In normal condition, this N.C. contact shorted to ALM-COM. In alarm status, it is open between ALM-NC and ALM-COM, N.O. is shorted to ALM-COM.
System Connection 3. System Connection The installations described below should be made by qualified service personnel or system installers. Before Installation Please refer to the following diagram for the system connections.
Front Panel Keypads 4. Front Panel Keypads 12 11 EDSR-900 10 2 1 22 9 8 7 6 5 4 3 13 14 15 16 17 18 19 20 EDSR-1600 1 21 2 SHUTTLE Ring and JOG Dial SHUTTLE : In Playback mode, turn the shuttle ring to fast forward/rewind the picture (600X maximum). In Pause mode, turn the shuttle dial to slow forward/rewind the picture (1/32 maximum). JOG : 2 In Pause mode, turn the jog dial to step forward/rewind the Picture. In Menu mode turn the jog dial to select options. CHANEL KEYS:.
Front Panel Keypads In Full screen mode this menu allows color adjustment for each video channel, all channels are separately adjustable. The selected item will show in red color bar. Use JOG to increase or decrease the value. Press ENTER to confirm and move to next item. After finished setting, press SELECT key to discard change or press MENU key to save and exit the dialog. In Multi-screen mode: In Multi-screen mode the SELECT key allows to define cameras in all multi-screen views. Press SELECT.
Operation 5. Operation (1) Insert a HDD (IDE) for Video Storage Insert one or two HDD (3.5” IDE) for Video Storage. The HDD should be set as Cable Select or MASTER. Both HDD need equal setting. (Normally the default setting of HDD is Master) Note: After hard disk case is inserted into the hard disk tray, be sure to turn the tray key in lock position.Otherwise, HDD will not be detected.
MENU flow 6. MENU FLOW Columns in brackets () only valid for EDSR-1600 CLOCK TITLE MOTION ( See page 11 ) ( See page 15 ) ( See page 18 ) CLOCK SETTING MENU : 2005/04/15 FRI : 13:01:02 DATE TIME MENU LANGUAGE: ENGLISH VIDEO SYSTEM: NTSC VERSION: 1.
MENU flow Columns in brackets () only valid for EDSR-1600 MATRIX MATRIX CONTROL SUB-MENU ( See page 27 ) ( See page 24) MONITOR-3 SETTING MENU MATRIX SETTING MENU CH DWELL CONTROL SETTING MENU RS232 BAUD RATE STOP BIT PARITY DATA BIT : 9600 BPS :1 : NONE :8 R485 BAUD RATE STOP BIT PARITY DATA BIT : 9600 BPS :1 : NONE :8 RS232/RS485 ID :1 CALL NONITOR MONITOR-1 MONITOR-2 MONITOR-3 MONITOR-4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DISK ( See page 28 ) DISK SETTING MENU DISK USAGE SIZE (GB) HD
MENU 6.1 CLOCK SETTING MENU CLOCK SETTING MENU DATE : 2005/04/15 FRI TIME : 13:01:02 : ENGLISH MENU LANGUAGE : PAL VIDEO SYSTEM VERSION: 1.09 2005/01/20 In CLOCK/LANGUAGE SETTING MENU , we define: (1) DATE : Current date, format: YYYY/MM/DD Year: 2000 ~ 2099, Month: 01~ 12, Date: 01~31, Week: Sunday~Saturday (2) TIME : Current time, format: HH:MM:SS Hour: 00 ~ 23, Minute : 00 ~ 59, Second: 00 ~ 59 (3) MENU LANGUAGE: ENGLISH (4) VIDEO SYSTEM: Factory default setting depend on machine “NTSC” or “PAL” .
MENU 6.2 DAYLIGHT SAVING TIME DAYLIGHT SAVING SETTING MENU DAYLIGHT SAVING: YES START TIME: LAST SUN IN MARCH CHANGE FROM 02:00 TO 03:00 STOP TIME: FIRST SUN IN OCTOBER CHANGE FROM 03:00 TO 02:00 This menu provides automatically switching to Daylight Saving Time and back to Normal Time.
MENU 6.
MENU 6.4 SEQUENCE SETTING MENU SEQUENCE SETTING MENU CH OP DWELL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS 03 SECS ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 10 to 16 only valid for EDSR-1600 In the SEQUENCE SETTING MENU, we define for MAIN Monitor (1) CH (Channel): Input channels. 1~9 for EDSR-900, 1~16 for EDSR-1600.
MENU 6.5 TITLE SETTING MENU TITLE SETTING MENU CH TITLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CH01_ _ _ _ _ CH02_ _ _ _ _ CH03_ _ _ _ _ CH04_ _ _ _ _ CH05_ _ _ _ _ CH06_ _ _ _ _ CH07_ _ _ _ _ CH08_ _ _ _ _ CH09_ _ _ _ _ CH010_ _ _ _ _ CH011_ _ _ _ _ CH012_ _ _ _ _ CH013_ _ _ _ _ CH014_ _ _ _ _ CH015_ _ _ _ _ CH016_ _ _ _ _ 10 to 16 only valid for EDSR-1600 In the TITLE SETTING MENU we define: The Title Setting Menu allows you to assign a title to each camera input.
MENU 6.6 COVERT SETTING MENU COVERT SETTING MENU CH OP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 10 to 16 only valid for EDSR-1600 In the COVERT SETTING MENU we define: The covert setting menu allows you to hide the requested camera on the display in a blue background. Change setting to “ON” for covering camera. Camera is invisible in Live and Playback mode unless this function is deactivated in COVERT menu.
MENU 6.7 ALARM RECORD SETTING MENU ALARM SETTING MENU CH OP TYPE DURATION 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 RST N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O N.O ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 05 SECS 10 to 16 only valid for EDSR-1600 In ALARM RECORDING MENU, we define (1) CH (Alarm input) : Select alarm input or RST for alarm reset input.
MENU 6.
MENU (5) HIT 1-9/16 TO MANUAL EDIT: Use the number keys (1~9 for EDSR-900 / 1~16 for EDSR-1600) to select a camera for setting the detection areas. The selected camera appears with a 16 x 12 grid (detection zones): PRESS MODE TO SWITCH ALL ON/OFF PRESS ENTER TO SELECT NODE USE JOG TO TOGGLE ON/OFF HIT MENU TO EXIT MODE switches all detection zones ON/OFF ENTER jumps to the next detection field. JOG wheel switches zone ON – active (area filled) or OFF – inactive (area empty) for motion detection.
MENU 6.9 RECORD SETTING MENU RECORD SETTING MENU NORMAL RECORD : 50 IPS SPEED : STANDARD QUALITY : REWRITE DISK FULL ALARM RECORD ON OPERATION : 50 IPS SPEED : STANDARD QUALITY PRE-ALARM RECORD ON OPERATION PREMANENT RECORD OPERATION : ON SPEED : 0,01 IPS In NORMAL RECORDING MENU we define (1) NORMAL RECORD: SPEED : Choose the normal recording speed. Maximum 60 (NTSC) / 50 (PAL). QUALITY: Define the video picture’s quality by selecting a compression rate.
MENU (3) PRE-ALARM RECORD: (with Alarm In and Motion) Pre-alarm duration is depending on recording quality (about 8-15 seconds). OP (Operation): Select ON to activate or OFF to deactivate pre-alarm recording. (4) PERMANENT RECORDING: This recording mode is used for continuous recording in the quality of NORMAL RECORD settings. Permanent record option: Operation: ON or OFF Speed : 0.01 IPS, 0.3 IPS, 0.5 IPS, 1 IPS, 5 IPS, 10 IPS, 15 IPS, 20 IPS, 30 IPS, and 60 IPS.
MENU 6.10 NETWORK SETTING MENU NETWORK SETTING MENU IP ADDRESS NET MASK ADDRESS GATEWAY ADDRESS MAC ADDRESS USER-NAME GUEST--GENERALADMNI--- : 192.168.010.005 : 255.255.255.000 : 192.168.010.001 : 00:5A:56:A3:87:1A PASSWORD GUEST--GENERALADMNI--- LEVEL GUEST--GENERALADMNI--- HTTP PORT: 0080 CTRL PORT: 6666 DATA PORT: 1111 2222 3333 4444 In the NETWORK SETTING MENU, we define (1)IP ADDRESS : Assign an fixed IP address for this unit, for example:192.168.010.
MENU (5) USER-NAME PASSWORD LEVEL The Login name and password are used to establish a network connection to the unit. The PASSWORD setup allows the administrator to set the new Login name and password with access level “SUPER”,”GENERAL” or “GUEST”. The system allows up to four users connected at same time with different access levels. “ADMIN ” : can view live/playback video, covert cameras and control all operation/setup. “GENERAL”: can view live and playback video. “GUEST”: can only view live display.
MENU 6.11 CONTROL SETTING MENU CONTROL SETTING MENU RS232 BAUD RATE : 9600 BPS STOP BIT :1 PARITY : NONE DATA BIT :8 RS485 BAUD RATE STOP BIT PARITY DATA BIT RS232/RS485 ID : 9600 BPS :1 : NONE :8 :1 In the CONTROL SETTING MENU, we define (1) RS232 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS232 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 38400 baud. The default setting from the factory is 9600 baud.
MENU 6.12 BUZZER SETTING MENU BUZZER SETTING MENU BUZZER : ENABLE RECORD-IN : ON ALARM-IN : ON MOTION-IN : ON DISK FULL : ON VIDEO LOSS : ON TIMER : ON In BUZZER SETTING MENU, we define the buzzer ON/OFF for following event: RECORD-IN, ALARM-IN, MOTION-IN, DISK FULL, VIDEO LOSS AND TIMER. Please select ON or OFF Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column.
MENU 6.13 ARCHIVE SETTING MENU ARCHIVE SETTING MENU : 720 X 480 : ON : TOP : ON : TOP PICTURE SIZE TIME STAMP TIME STAMP POS WATER MARK WATER MARK POS In the ARCHIVE SETTING MENU, we define for picture and movie export to CF-card: (1) PICTURE SIZE : Selects picture size for copying image to CF card: Big size:720x480 / 720x576 for NTSC / PAL. Small size:352x240 / 352x288 for NTSC / PAL. (2) TIME STAMP : ON: Shows the time stamp on the picture when copying image to CF card.
MENU 6.14 MATRIX SETTING MENU MONITOR-0 SETTING MENU MATRIX SETTING MENU CALL MONITOR MATRIX-0 MATRIX -1 MATRIX -2 MATRIX -3 MATRIX -4 ENTER CH DWELL EVENT 1 2 3 4 5 6 7 8 9 … … 07 SECS 07 SECS 07 SECS 07 SECS 07 SECS 07 SECS 07 SECS 07 SECS 07 SECS … … NONE NONE NONE NONE NONE NONE NONE NONE NONE (Dialog 1) (Dialog 2) … more In the MATRIX SETTING MENU, we define the standard sequences for each matrix monitor and event, which override these sequences.
MENU 6.15 DISK MENU DISK SETTING MENU DISK USAGE HDD-1 HDD-2 SIZE (GB) 120 120 RECORD POS *78,2% 0% PLAY POS *39,5% 0% DISK RENEW NO NO In the DISK menu, the Hard Disks’capacity and status are displayed. Additionally, the Hard Disks’indexes can be deleted. SIZE (GB): Display of Hard Disk capacity in GB for HDD1 (upper Slot) and HDD2 (lower slot). RECORD POS: Display of current recording position on the Hard Disk.
MENU 6.16 PTZ SETTING MENU PTZ SETTING MENU PTZ ENABLE: OFF PTZ Port: RS485 PROTOCOL: PELCO-D BAUD RATE: 9600 PTZ ADDRESS: CH1: 001 CH2: 002 CH3: 003 CH4: 004 CH5: 005 CH6: 006 CH7: 007 CH8: 008 CH9: CH10: CH11: CH12: CH13: CH14: CH15: CH16: 009 010 011 012 013 014 015 016 The EDSR600/900/1600 Recorder from FW 1.09 provides telemetry control over network. Local device telemetry control at the EDSR recorder is not possible. Telemetry bus may be connected to RS-232 or RS-485.
MENU Example: Connection ED-2250 Dome to EDSR600/900/1600 Control of EverFocus ED2250 speed dome is possible with setting PELCO - D or PELCO - P protocol. Functionality is limited compared to keyboard control with original protocol, available are PTZ and preset functions (no ED2250 setup menu). PELCO - D: DIP switch 501 at ED2250 1 234 5678 ON OFF SW501 PELCO- P: DIP switch 501 at ED2250 1 2 34 5 678 ON OFF Address setting DIP switch 500: an offset +1 is required.
MENU RS-232 - Connection ED2250 Dome 31
MENU 6.17 SYSTEM SETTING MENU SYSTEM SETTING MENU PLAY WITH AUDIO-1 : ON PLAY WITH AUDIO-2 : ON PLAY SPEED 50 IPS : PASSWORD ENABLE : DISABLE PASSWORD LEVEL 2 : 222222 PASSWORD LEVEL 3 : 333333 SYSTEM UPDATE: NO LOAD DEFAULT: NO CF FORMAT: NO In the SYSTEM SETTING MENU, we define (1) PLAY WITH AUDIO: AUDIO-1, AUDIO-2 ON/OFF: Playback with or without audio. (2) PLAY SPEED: Set the playback speed. Maximum 60 (NTSC) / 50 (PAL). (3) PASSWORD ENABLE: Enable/Disable the password protection.
Recording 7.1 INSTANT RECORDING Press REC key to start continuous recording with setting of “NORMAL RECORD”. REC The recording rate and recording quality are set in the RECORD SETTING MENU. The LCD screen on the front panel of DVR will display as follows: 2003/11/23 REC 21:56:47 50 HDD1 IPS 70% 21:56:52 Display shows operation status, active HDD, record position on active HDD, record frame rate ant current time.
Recording 7.3 PERMANENT RECORDING No manual operation is required, the automatic permanent recording is defined and activated in the RECORD menu. 7.4 TIMER RECORDING No manual operation is required, the settings for TIMER recording is defined in the TIMER menu.
Playing Back 8.1 NORMAL PLAYBACK (1) Playback Press the PLAY key to start playing back the stored video/audio from the last SEGMENT. PLAY NOTE: In Duplex mode (simultaneous record and playback) the playback speed is limited to 25 IPS. For real-time display of 50 IPS records stop recording before starting playback. (2) Fast Forward/Reverse Playback During playing back, turn the SHUTTLE ring clockwise to start fast forward playing back. The speed will be shown on the screen at the bottom of the screen.
Search Playback 8.2 SEARCH PLAYBACK (1) Segment List search playback Press SEARCH key to enter the SEARCH MENU dialog. SEARCH SEARCH MENU BY SEGMENT LIST BY ALARM LIST BY DATA TIME Turn the JOG dial to select BY SEGMENT LIST and press ENTER key. A segment is a range on the HDD, beginning with record start (manual, alarm, motion or after power loss) and ending with record stop. NOTE: If the recorder starts to overwrite a HDD, also a new segment will be generated.
Search Playback (2) Alarm List search playback Press SEARCH key to enter the SEARCH MENU dialog. SEARCH SEARCH MENU BY SEGMENT LIST BY ALARM LIST BY DATA TIME Turn the JOG dial to select BY ALARM LIST and press ENTER key. The submenu will display as follows: ALARM SEARCH 00001 00002 00003 M01 2003/04/24 19:03:29 HDD 1 A03 2003/04/25 12:30:30 HDD1 M03 2003/05/20 12:00:00 HDD2 A01 : Alarm recording by Alarm-in 1. M03: Motion recording by camera 3. T : Timer recording.
Search Playback (3) Date/Time Search Playback Press SEARCH key to enter the SEARCH MENU dialog. SEARCH SEARCH MENU BY SEGMENT LIST BY ALARM LIST BY DATA TIME Turn the JOG dial to select BY DATA TIME and press ENTER key. The submenu and instruction will display as follows: DATE/TIME SEARCH YYYY/MM/DD HH:MM:SS HDD 2003 /01 /01 21: 33: 26 1 PRESS SEARCH TO START SEARCH PRESS MENU TO EXIT Turn the JOG dial to select desired date/time and stored hard disk.
DATA EXPORT 9. DATA EXPORT Insert a Compact Flash card into the Compact Flash slot on the front panel of DVR. When inserting the Compact Flash card, make sure that insert direction is correct. NOTE: COPY function will interrupt the recording for the duration of copy procedure. The MAIN monitor displays the message: "WARNING: RECORD STOPS FOR COPY FUNCTION" 9.1 STILL IMAGE COPY PAUSE The still image copy function is possible in all playback view modes. Press the PLAY key to start playing back.
DATA EXPORT 9.2 COPY TO MOVIE FILE NOTE: COPY function will interrupt the recording for the duration of copy procedure. The MAIN monitor displays the message: "WARNING: RECORD STOPS FOR COPY FUNCTION" Press the PLAY key to start playing back. PLAY Press COPY key and then the copy menu and instruction appears.
DATA EXPORT 9.3 EXPORT EVENT LOG LIST This function allows to export the event log list to CompactFlash – Card. The generated text file in in *.txt format. Press „DISPLAY“ key and hold the key for over 2 seconds.
MONITOR VIEWS / OPERATION 10. MONITOR VIEWS / OPERATION The EDSR900/1600 digital recorders provide 1 main monitor and 5 matrix monitors (include 1 call monitor). These monitors have different functionalities: Main monitor: - Full screen and multi screen display: EDSR-900: Full, 4, 6, 7, 8, 9, PIP, and 2x zoom EDSR-1600: Full, 4, 6, 7, 8, 9, 10, 13, 16, PIP, sequence and 2x zoom - Live - and Playback display - OSD for camera title, status messages, date, and time.
MONITOR VIEWS / OPERATION 10.2. CALL / MATRIX MONITORS Press CALL to change settings for CALL / MATRIX monitors. The Main monitor shows following dialogue: CALL MATRIX NORMAL STATE SETTING MENU PRESS CALL TO SET CALL MONITOR PRESS 1-4 TO SELECT MATRIX Select the monitor by pressing CALL or the numeric keys 1~4.
REMOTE CONTROL / OPERATION 11. REMOTE CONTROL 11.1 RS-485 REMOTE CONTROL The new standard EverFocus EDSR remote control protocol allows sophisticated installations with DVR remote control at different installation sites. EDSR remote control is supported by the keyboards KS KBJ (with 3-axis joystick and 2 additional RS-485 ports for telemetry control with independent telemetry protocols) and KS KBK (no telemetry). Up to 32 units are allowed in the RS -485 bus.
REMOTE CONTROL / OPERATION Wiring diagram single EDSR control Wiring diagram multiple EDSR control RS485B /yellow RS485A /white RS485B /yellow RS485A /yellow RS485A /yellow RS485B /black RJ12Patchcable RJ12Patchcable RS485A /white RJ12Patchcable RS485A /yellow RJ12Patchcable RS485A /yellow RS485B /black RJ12Patchcable RS485A /yellow RS485B /black RJ12Patchcable Wiring diagram multiple keyboard control RS485B /yellow RS485A /white RJ12Patchcable RS485A /yellow RS485B /yellow RS485B /yello
IR REMOTE CONTROLLER / OPERATION 11.2 IR Remote Controller (optional) The remote controller (RC-200, Figure 1) is an accessory to enhance the handy operations of the DVR. You can perform all the settings and operations by the remote controller. The effective distance is up to 10 meters without any obstacle. The keypad functions are same as the front panel key button of the DVR. There are some replacement keys for JOG and SHUTTLE, definitions are: JOG : Same as turning the JOG clockwise.
View From Internet/Intranet 12. View From Internet/Intranet Basic Operations and Login Display: Before you start: Please make sure the service ports 0080, 1111, 2222, 3333, 4444, and 6666 all enable in both of two end point and LAN(control PC and been controlled DVR). Please enable the “ActiveX” for java plug-in (Please refer to Microsoft IE manual ). Please set the NetMask 255.255.255.000 for network configuration of your control PC, when both of them in the same LAN.
View From Internet/Intranet Main Screen 10 11 19 12 13 14 1 2 3 4 5 6 7 8 9 15 16 17 18 Above diagram is the main screen display. The icons on the lower corner of the screen are mainly for control and Configuration, those on the right corner are for status indication. If any icon is grayed, it means that the specific function is not accessible in the current mode. The followings are a brief description for each of the icons. 1. REV. PLAY : Reverse Video Playback. 2.
View From Internet/Intranet 10. The system allows up to 3 ways playback video, by SEGMENT, ALARM LIST and DATE TIME.
View From Internet/Intranet 11. All available segments are shown in the list. Click to select and highlight. 12. Click to playback selected video segment. 13. Press this icon to show the segment or list. 14. Current connection and playback status is shown along with date and time. 15. Full screen view. 16. Quad screen view. 17. Nine split screen view. 18. Sixteen split screen view (only for 16 CH DVR). 19. A pop-up menu to select camera to view will be shown by pressing right mouse button.
MENU PTZ-CONTROL WITH WEB BROWSER (from FW 1.09 only) If the checkbox "PTZ CONTROL" is activated in the Web’s applet of the EDSR600/900/1600, the screen shows the telemetry control functions. Please consider the time delay in video network transmission at manual PTZ control! PTZ network control is not recommended for ISDN or analogue transmission lines due to slow video transmission rate and long video delay. Control buttons: 1. PTZ CAMERA: Camera selection 2.
PASSWORD PROTECTION/ OPERATION 13. PASSWORD PROTECTION The EDSR 900/1600 provides 3 levels with different user rights in operating, if password protection is activated in SYSTEM menu. USER RIGHTS: LEVEL 1: Active after start up, user is allowed to switch live views, no access to record, search, playback and menu functions. No password for this level. LEVEL 2: Access to record, playback, search functions, no set up menu access. LEVEL 3: Access to all functions.
Appendix-A LAN Functional Specification Specifications: Network Interface: LAN controller Chip: LAN Connector: Protocol: Remote Access: Image Compression: Used Ports: Max. user number: Frame rate: 10Mbits/s Ethernet (10Base T) RealTek 8019 RJ-45 HTTP,TCP/IP.ICMP,ARP Standard browser such as internet Explorer / Netscape with JAVA support JPEG 80, 1111, 2222, 3333, 4444, 6666 4 max.
Appendix-B Time Lapse Mode Recording Time Table ? When Recording with 160GB HDD (Estimated with typical image-low noise level) Lower Low Basic Standard High Superior : 15 kB : 19 kB : 23 kB : 27 kB : 31 kB : 35 kB LOWER 15 49.4 98.8 148.1 197.5 296.3 592.6 2963 5925.9 9876.5 14814.8 LOW 19 39 78 117 155.9 233.9 467.8 2339.2 4678.4 7797.3 11695.9 160 system storage(GB): PICTURE QUALITY (KB) BASIC STANDARD HIGH SUPERIOR 23 27 31 35 32.2 27.4 23.9 21.2 64.4 54.9 47.8 42.3 96.6 82.3 71.7 63.5 128.8 109.
Appendix-B ? When Recording with 320GB HDD Lower Low Basic Standard High Superior (Estimated with typical image-low noise level) : 15 kB : 19 kB : 23 kB : 27 kB : 31 kB : 35 kB LOWER 15 98.8 197.5 296.3 395.1 592.6 1185.2 5925.9 11851.9 19753.1 29629.6 LOW 19 78 155.9 233.9 311.9 467.8 935.7 4678.4 9356.7 15594.5 23391.8 320 system storage(GB): PICTURE QUALITY (KB) BASIC STANDARD HIGH SUPERIOR 23 27 31 35 64.4 54.9 47.8 42.3 128.8 109.7 95.6 84.7 193.2 164.6 143.4 127 257.6 219.5 191.2 169.3 386.5 329.
Appendix C: Serial Interface Specifications Serial Interface Specifications 1. RS-232 pin assignment The DVR may be controlled by a computer or a terminal via the standard D-SUB 9-pin RS-232 connector.
Appendix C: Serial Interface Specifications 3. Remote Control Protocol A computer or a terminal can be used to control the unit by sending the packet as following. 1-1.
Appendix C: Serial Interface Specifications 2-1. The format of message packet is as follows: Length Byte (Prefix: 0x86, 0x87, or 0x88 ..... ) Receiver ID high byte Receiver ID low byte Opcode Byte Data Byte1 Data Byte2 Data Byte3 Checksum Byte 2-2. Length Byte This Length Byte is also a prefix. Bit7 must be 1. EX: 0x87 ==> this packets has 7 bytes length.
Appendix C: Serial Interface Specifications 2-3. Receiver ID 2-3. Receiver ID 1).
Appendix C: Serial Interface Specifications 2-4. Opcode Byte & Data bytes 2-4-1. OPcode OPcode Data1 Function 0x4B Keycode A remote key pressed 0x4D command Matrix command 2-4-2.
Appendix C: Serial Interface Specifications 2-4-3.
Appendix-D Alarm I/O pin assignment The alarm connector, Figure 1, is used to provide one sensor alarm input for each camera input. For easy operation, an alarm extension board, Figure 2, is provided to connect to the alarm connector. Each alarm input requires two wires, one wire connects to the desired alarm input pin, the second wire connects to the ground.The alarm signal assignment is shown at the following.
EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan www.everfocus.com.tw China Office: Room 609, Technology Trade Building, Shandgdi Information Industry Base, Haidian District, Beijing,China www.everfocus.com.cn USA Office: 2445 Huntington Drive, San Marino, CA 91108, U.S.A. www.everfocus.com Japan Office: 1809 WBG Marive East 18F, 2-6 Nakase.Mihama-ku. Chiba city 261-7118, Japan www.everfocus.