Manual
Table Of Contents
- Introduction
- Getting Started
- General Operation
- OSD Root Menu
- Search and Playback
- System
- Remote Access to the Mobile DVR
- Accessing the Mobile DVR on the Network
- Remote Live View
- Menu Bar
- Express
- Camera
- Basic Setting
- Adjust Setting
- Record
- Event
- Alarm
- Video Loss
- Motion
- GPS Event
- G-Sensor Event
- Other
- Disk
- Disk
- SD Card
- Lock/Format
- Display Setting
- Monitor OSD
- M/T SEQ
- Network
- LAN
- Wireless
- Mobile
- DDNS
- FTP
- Alarm Server
- Remote/Mobile
- Xfleet
- Schedule
- Express Setup
- Holiday
- Schedule
- System Setting
- Date/Time
- Daylight Saving
- User Group
- User Management
- I/O Control
- EKB200 Setting
- Miscellaneous
- Information
- System
- Log
- Copy
- Search
- Time Search
- Event Search
- PTZ
- Specifications
- Troubleshooting
- Appendix A: Network Overview
- Appendix B: Linksys & D-Link Port Forwarding
- Appendix C: Timing of Alarm Modes
- Appendix D: Express Setup Recording Value Selection Rules
- Appendix E: IR Remote Control
- Appendix F: RTSP URL Syntax
- Appendix G: Tested Card Brands
- Appendix H: Recording Backup through EF-Reader
- Appendix I: Auto HDD Retry Mechanism
EMV400 FHD Mobile DVR
86
6.4.5 G-Sensor Event
You can configure the gravity value of the X, Y and Z-axial, once the vehicle reach the setup
value, the alarm will be triggered.
G-Sensor: Select On / Off to enable / disable G-Sensor function.
Email Notify: Check box to enable email notification when GPS is lost. Email operation
requires valid email settings entered in the Email setup screen (see 6.7.4 Email).
Network Alarm: Check box to send out a network alarm to the client PC. This feature works
with EverFocus’ CMS software. You will need to configure the Alarm Server for mobile DVR
to send network alarms to the client PC (see 6.7.7 Alarm Server).
XY Axial Trigger Value: Set XY Axial trigger value, alarm will be triggered when acceleration
reaches this value in horizontal direction with respect to the horizon. The available setup
value is between 0 ~127 (1000mg = 1 Gravity).
Z Axial Trigger Value: Set Z Axial trigger value, alarm will be triggered when vertical
acceleration reaches this value. The available setup value is between 0 ~127 (1000mg = 1
Gravity).
Alarm Output: This will transmit a signal through the alarm output relay. It can be set to
either “NONE” (not active), “1” (active) or “2” (active).
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses the “Enter” key or
resets the alarm remotely.
Transparent: Alarm output remains active until event ends.