EAN Plus Series IP Box Camera User’s Manual * Lens not included.
Copyright 2012 EverFocus Electronics Corp. All rights reserved. No part of the contents of this manual may be reproduced or transmitted in any form or by any means without written permission of the EverFocus Electronics Corporation. EverFocus 12F, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 2380 www.everfocus.com.
Regulatory Notices About this document All the safety and operating instructions should be read and followed before the unit is operated. This manual should be retained for future reference. The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice.
Safety Notice These limits are designed to provide reasonable protection. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Terms and Trademark Ethernet, Internet Explorer, Linux, Microsoft, Windows, WWW are registered trademarks of the respective holders. Other product names appearing in this User's Guide may be trademarks or registered trademarks of their respective holders. Java™ and all Java-related logos and trademarks are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries.
CONTENTS 1. Introduction ....................................................................................................................................... 1 2. Overview ............................................................................................................................................ 2 3. Features ............................................................................................................................................. 3 4. Installation ......................
.3.1 Network ............................................................................................................................. 27 7.3.2 DDNS .................................................................................................................................. 29 7.3.3 SMTP / FTP ......................................................................................................................... 31 7.3.4 HTTPS ......................................................................
EAN Plus Series 1. Introduction The EAN Plus series is a box-type IP camera delivering image quality of up to 3-megapixel. The EAN Plus series features the Wide Dynamic Range (WDR) function, which can provide clear images even under back light circumstances where intensity of illumination can vary excessively. A built-in micro SD card slot and Power over Ethernet (IEEE802.3af) features are also provided. You can power the camera over the network or by connecting the camera to a 12V DC power supply.
EAN Plus Series 2. Overview 1 2 3 4 5 6 7 9 8 10 11 No. 1 2 3 4 5 6 Item Name Memory Card Slot Power LED DC 12V Port Ethernet / PoE Reset Button I/O Terminal Block Descriptions Insert a micro SD / SDHC card to store recording data. Indicates the power is supplied. Connects to power. Connects to a 10/100 Ethernet or PoE. Resets all configurations to factory default. Connects I/O devices. Connects to a portable monitor for setting the focus and angle of the camera during initial installation.
EAN Plus Series 3. Features • 1/3” Panasonic CMOS sensor (for EAN3120 Plus / 3220 Plus) 1/2.8” Sony CMOS sensor (for EAN3300 Plus) • • Triple streams (stream 1 / 2 / 3 from H.
EAN Plus Series 4. Installation 4.1 • • • • Packing List EAN Plus Series Camera (lens not included) x 1 Software CD x 1 Quick Installation Guide x 1 Tool Packet x 1 (contains the following items) - C-mount lens adapter - ¼-20 UNC thread mounting bracket and 2 screws - Hexagon wrench - Power pigtail cable Note: Contact the shipper if any items appear to have been damaged in the shipping process. If any items are missing, notify your EverFocus Electronics Corp.
EAN Plus Series 4.2 I/O Terminal Block The I/O terminal block, located on the rear panel of the camera, can be used to develop application for alarm input and output. 1 2 3 4 4.3 Pin Assignment No. Function No. Function 1 Alarm COM 3 Alarm Input 2 Alarm Output 4 Digital GND Lens Installation and Adjustment You can install either a CS-mount or a C-mount lens into the camera. It is recommended to use a lens with aperture ratio of F/1.4 or smaller. Please refer to the following reference steps.
EAN Plus Series 4. When making final focus adjustment, place the ND filter in front of the lens to force the lens iris to open, and then adjust the lens using the Focus / Zoom Screws. Note: To use the ND filter, remove the protective sheets from both sides of an ND filter. 5. Lock the Focus Screw and then remove the ND filter. C-Mount Lens: 1. Remove the cover cap from the camera body. 2. Install the lens into the camera body using the supplied C-mount lens adapter. 3.
EAN Plus Series 4.5 Basic Connection 3 Audio 1 Ethernet (PoE) Power DC 12V Micro SD 3 Out Video Out 4 GND Reset COM Out In 2 In Alarm 5 1. Use a standard network cable to connect the camera to the network. 2. Connect the camera to power using one of the following methods: • Plugging the supplied power pigtail cable to the DC 12V port. • Using the PoE function and the power will be provided over the network cable. 3. Optionally connect the camera to a speaker or microphone.
EAN Plus Series 5. Accessing the User Interface This section explains how to access the Web interface of the camera for configuration. 5.1 Assigning an IP Address You have to assign an IP address for your camera to be accessible. To assign an IP address to the camera, use the IP Utility (IPU) software included in the software CD. Please connect the IP camera in the same LAN of your computer. 1. Install and then start the IPU program . The following dialog box appears. 2.
EAN Plus Series 4. Type the user ID and password. Click OK. Note: 1. The default user ID is user1 and the default password is 11111111. 2. If you select more than one camera that has the same user ID / password, you will be able to log in several cameras at once. 5. To change the IP address, double-click the IP Address of the camera. Type a new IP address and then click Set IP Address to save the settings. You can also change the other settings by double-clicking the values.
EAN Plus Series 5.2 Settings for Microsoft Internet Explorer To enable Remove Live View, Firmware Upgrade and ActiveX Prompt on Internet Explorer, some settings have to be complete. Please follow the steps below: 1. On the computer, click Start > Control Panel > System and Security > Action Center (click Change User Account Control Settings), the User Account Control Settings window appears. Adjust the slide bar to Never Notify and then click OK. Restart your computer if requested. 2.
EAN Plus Series 3. In the Download unsigned ActiveX controls field, select Prompt. In the Include local directory path when uploading files to a server field, select Enable. Click OK. 4. In the Internet Options window, click the Advanced tab and then disable Enable memory protection to help mitigate online attacks. Click OK.
EAN Plus Series 5.3 Connecting the Camera to the Network There are three methods to connect the IP camera to the network: Router or LAN Connection, Direct High-Speed Connection and One-to-One Connection. Router or LAN connection This is the most common connection in which the IP camera is connected to a router and allows multiple users on and off site to see the IP camera on a LAN/WAN (Internet). The camera must be assigned an IP address that is compatible with its LAN.
EAN Plus Series Direct High-Speed Connection In a Direct High-Speed Connection, the camera connects directly to a modem without the need for a router. You need to set the static or dynamic WAN IP address assigned by your ISP (Internet Service Provider) in the camera’s configuration web pages. To access the camera, just type “http://xxx”, where xxx is the IP address given by your ISP. If you have a dynamic IP address, this connection may require that you use DDNS for a reliable connection. Please refer to 7.
EAN Plus Series 5.4 Live View Window 1. Press the button to display the "Live View" window. Double-click on the image to show a full-screen display, double-click again or press ESC to return to the normal display. If you experience video feed lag time (if connected via Internet), you can reduce the resolution or limit the number of streams. See 7.4.1 Multi Streaming. 2.
EAN Plus Series 4. Press the button to exit the system and close this browser page. 5. Video Stream Select the Video Stream (Stream 1, Stream 2 or Stream 3) that will be displayed in the video box on the right. Stream 2 and Stream 3 are only selectable if you have enabled the stream. The default setting is Stream 1 only. See 7.4.1 Multi Streaming. 6. View Size Use this to select the appropriate view size and shape of the video box on the right.
EAN Plus Series 11. One Push This function is only available for EAN3120 Plus / 3220 Plus. The One Push button can be displayed on the live view window by enabling the Show One Push Buttons function on the User Config < Live View Config Setting page (see 7.2.1 Live View Config). To enable the button (turned from faded to clear), on the Video < Advanced Setting page, select One Push from the White Balance Settings Mode drop-down list, and click the Apply button.
EAN Plus Series 6. Playback You can remotely play back the recordings stored in the on-camera micro SD card on the Web interface, or play back the recordings stored in the computer using the ARV Viewer included in the software CD. Playback is designed as a quick way to check recent recordings that were triggered by Events that were configured to “Record to SD Card” in the Settings > Event > Event Settings page (see 7.7.1 Event Settings).
EAN Plus Series Search by File: Click the Search button to search for all recording files on the on-camera SD card. Search results will be displayed in the Filename area. Search by Time: Click the calendar icon and select the date and time from which you want to search until the present moment. Click search to get your search results, which will be displayed in the Filename area.
EAN Plus Series 6.2 Setting up the Playback Function Note that the Playback function will not be active until the user has inserted a micro SD card in the camera’s micro SD card slot. The card may also have to be formatted in the Settings submenu. Micro SD Card Slot 6.2.1 Preparing the Micro SD Card Once you insert a functional micro SD card into the slot, the Playback button on the Live page should become active within seconds (see section 6.2.2 below – the grey letters should turn white).
EAN Plus Series 5. In the “Event Triggered by” field, click on Manual Trigger. 6. Below this, check “Enable This Event”, “Enable Post-trigger Buffer”, and “Record to SD Card”. 7. To save your settings, click OK, or close the box by clicking on the red x icon at top right of the box (in which case you will be asked if you want to save the data, to which you should reply OK). The box will close and the new event will be listed in the list area of the Event Settings page. 8.
EAN Plus Series 6.3 Playing Back Using ARV Viewer You can play back the recordings stored in the computer using the ARV Viewer included in the software CD. To store the recordings in the computer, please refer to Recording List > Copy in 6.1 Remote Playback using Playback Page. 1 4 5 6 2 7 8 3 9 10 No. Item Name Descriptions 1 Snapshot Click to take and save a snapshot. 2 Load File Click to load the recordings for playing back.
EAN Plus Series 7 Settings Click the Settings button on the Live View Window to enter the settings submenu. There are nine buttons on the left-side of the submenu: Live, System Info, User Config, Network, Video, Audio, User, Event and System. Click the Live button can go back to the Live View Window. 7.1 System Info The System Information and System Log can be checked on this page. Click the top tab of the one you want to see. 7.1.
EAN Plus Series 7.1.2 Log Click the Log tab, the following dialog box appears. The sequence number, date, time and event messages of the log event will be displayed in the System Log field. The log will display the last 256 log events. Click the Export button to export the system log event list into a “.txt” file and select the location where the exported log file will be saved to.
EAN Plus Series 7.2 User Config Each user can set a different configuration for his/her Live page here. These settings will be applied to the logged-in user’s Live page every time he/she logs in. 7.2.1 Live View Config 【Video/Audio Connection Protocol Setting】You can transmit the data stream from the IP cameras using the RTSP (Real Time Streaming Protocol) on the network. The RTSP is a protocol that allows you to access video streams by using the compatible media players.
EAN Plus Series 【Date/Time Format Used in Text】Click the dropdown menu to select date/time format from the listed options. Click on the desired hour format. Click Apply to apply the setting changes or Reset to reset without saving the change. 【Live View Layout Settings】 Check the “Show One Push Buttons” boxes if you want to show these buttons on the Live View Page. Uncheck these boxes to hide these buttons. This function is only available for EAN3120 Plus / 3220 Plus. 7.2.
EAN Plus Series 7.2.3 Language Select the language to be displayed on the Web interface of the IP camera. The default language is English. To add a new language not listed in the current Language list, click the Browse button to locate the new language file (.evb) on your computer and then click the Upload button. Updated language files might be available on the manufacturer’s website. Contact your vendor if required. Click Apply to apply any changes or Reset to reset without saving the changes.
EAN Plus Series 7.3 Network This page covers network-related settings, including Network, DDNS, SMTP/FTP, HTTPS, SNMP, and Network Alarm. 7.3.1 Network The following information is required to configure the network settings. Contact your network administrator or your internet service provider to get the info. 【IP Settings】 IP Type: Refer to the network administrator for these settings of the server.
EAN Plus Series Note: If PPPoE is selected as the IP type, the supplied IP Utility program will not be able to detect the device. IP address: When DHCP is not used, the user needs to manually enter the IP address of the camera. Do not enter an IP address that is already used for your computer or other network cameras. Subnet Mask: This field is used to set the netmask for your network, so that the IP camera will be recognized within the network. Example: 255.255.255.0.
EAN Plus Series 7.3.2 DDNS DDNS (Dynamic Domain Name System) is a service used to map a domain name to the dynamic IP address of a network device. You can set up the DDNS service for remote access to the IP camera. DDNS assigns a domain name (URL) to the IP camera, so that the user does not need to go through the trouble of checking if the IP address assigned by DHCP Server has changed.
EAN Plus Series FQDN: Type the fully qualified domain name applied from the DDNS server provider. For example, xxxx.dyndns.com Username / Password: Type the login account of your DDNS server provider. Click Apply to apply the setting changes or Reset to reset without saving the changes. Note: 1. In order to support the full functionality of the camera, you must open the port numbers (80, 554, 443) on the router for remote access to the IP camera.
EAN Plus Series 7.3.3 SMTP / FTP 【Set SMTP Server (email)】This area is for configuring the mail server that is used to send e-mail notifications from the camera to predefined addresses via SMTP. Note that to enable e-mail notification function, you have to check the Send Mail Notification item on the Event dialog box (see 7.7.1 Event Settings). SMTP Server: Enter the IP address or the host name of the SMTP server used to send e-mails. SMTP Port: Enter the port number for SMTP. The default is 25.
EAN Plus Series Receiver Address: Input the e-mail addresses for receiving an e-mail message when an EVENT is enabled and triggered. Please use “;” to separate multiple addresses. Sender Address: Input the sender’s e-mail address, so that the receiver can recognize the sender when an Event message is received. Attach Image: Check this box if you want to attach an image when an alarm is triggered or an IP camera detects events.
EAN Plus Series 7.3.4 HTTPS Hypertext Transfer Protocol Secure (HTTPS) is a combination of the Hypertext Transfer Protocol and the SSL/TLS protocol and provides encrypted communication and secure identification of a network web server. Before using the HTTPS function for communication with the IP camera, a Certificate must be created first. There are two ways to create and install a certificate: Create Self-Signed Certificate and Create Certificate Request.
EAN Plus Series 2. Type the required Certificate information and then click the Apply button. The subject line will be displayed in the Installed Certificate Information field. 3. Click the Property button, a pop-up window appears to display the details of the certificate. 4. To optionally create and install other certificates, remove the existing one by clicking the Remove button to erase the certificate. 5.
EAN Plus Series 2. Type the required Certificate information and then click the Apply button. The subject line will be displayed in the Created Request field 3. Click the Property button, a pop-up window appears to display the details of the certificate. 4. To optionally create and install other certificates or request, remove the existing one by clicking the Remove button to erase the certificate or request. 5.
EAN Plus Series 7.3.5 SNMP The default values for SNMP v1/v2/v2c and SNMP v3 are already filled in. Click either of the Enable buttons to enable either of the two. Make your changes as desired. Click on the Trap Address field to enter the digits, if required. 7.3.6 Network Alarm This function works with EverFocus’s CMS software, e.g. the PowerCon or the Power Video Plus. For the setting details, please refer to the CMS network alarm protocol.
EAN Plus Series 7.4 Video The settings relating to video such as streaming, camera OSD can be configured on this page. The "Video" page has five tabs: Multi-streaming, Camera, Advanced, ROI and Privacy Mask. 7.4.1 Multi Streaming 【Stream Settings】 This IP camera can output three video streams simultaneously. For each of these streams, the user can set the compression format, resolution, bit rate, and frame rate individually. Stream 1 is always enabled for live view.
EAN Plus Series Format: Select the encoding format – H.264 or MJPEG. Resolution: Select the most suitable resolution for your needs. Frame Rate: Select from 1 to 30 fps. Bit Rate: If required, select whether you want the stream to stream a Constant Bit Rate or a Variable Bit Rate, and set the values of whichever option you choose. Click Apply to apply the setting changes or Reset to reset without saving the changes.
EAN Plus Series 7.4.2 Camera 【Image Settings】Set the Brightness, Saturation, Contrast or Sharpness of the image. Click Apply to apply the changes, or Reset to reset without saving the changes. 【Camera Settings】 Mirror: Switch Mirror ON to rotate the image horizontally around a vertical axis. Flip: Switch Flip ON to rotate the image vertically around a horizontal axis.
EAN Plus Series WDR: The Wide Dynamic Range (WDR) function provides clearer images when both of the very bright and dark areas simultaneously appear on the camera view. There are four value options: OFF, Low, Middle and High. Note that when WDR is ON, some parts of the image may appear solarized. This is normal for WDR, and is not a camera malfunction. This function is only available for EAN3120 Plus / 3220 Plus.
EAN Plus Series 7.4.
EAN Plus Series 【Camera Settings】 Lens (IRIS Control): Select DC or Manual for IRIS control. This function is only available for EAN3220 Plus. Exposure Settings (AE): This setting is used to adapt to the amount or type of light used by the camera. Note the settings vary among models. Mode: This function is not available for EAN3220 Plus. Automatic Light Control (ALC): This option is only available for EAN3120 Plus / 3300 Plus.
EAN Plus Series Black Level: Set the Black level here. This function is only available for EAN3300 Plus. WDR: The Wide Dynamic Range (WDR) function provides clearer images when both of the very bright and dark areas simultaneously appear on the camera view. There are four value options: OFF, Low, Middle and High. Note that when WDR is ON, some parts of the image may appear solarized. This is normal for WDR, and is not a camera malfunction. This function is only available for EAN3120 Plus / 3220 Plus.
EAN Plus Series For EAN3220: You can configure one area to apply the BLC function. Select ON (BLC), the setup buttons appears (see image below). Select Low / Middle / High from the BLC Gain drop-down list. To set up a BLC area, click the Edit Area button and then click on the blue color tab to turn your mouse cursor into a blue pen. Move the cursor to the position on the right screen where you want the BLC rectangle to start and then click.
EAN Plus Series Back Light: This option is only available for EAN3300 Plus. The Back Light function is useful when the background of the subject is very bright and the subject itself is dark. Select Back Light and adjust the slide bar to the left / right for setting up the back light value. The higher the value, the more the backlight compensation. Front Light: This option is only available for EAN3300 Plus.
EAN Plus Series White Balance Settings: Select the mode that delivers the best quality image for the camera’s light environment. There are five options: Auto, Manual, Indoor, Outdoor, One Push. Auto: Select to let the camera automatically adjust the White Balance. In the Auto mode the camera computes the white balance value output using color information from the entire screen.
EAN Plus Series Sharpness Settings: Select the sharpness level of the image. A low sharpness level will deliver a softer, less detailed image. A high level will deliver a sharp, highly detailed image. Switch Resolution Enhancement ON to enable the resolution enhancement function. Contrast: Select the contrast level of the image. Suppress Function: This function is only available for EAN3300 Plus.
EAN Plus Series 7.4.4 ROI (Region of Interest) The Region of Interest (ROI) function allows users to set up multiple regions within an image with better quality and less distortion than the rest of the image. You can also use this function together with the Digital Zoom function on the Live View Page to get a better image result. Up to eight ROIs can be configured in the ROI settings page. To set up an ROI region: 1. 2. 3. 4. 5. Select an ROI number from the ROI No. drop-down list.
EAN Plus Series 7.4.5 Privacy Mask The Privacy Mask can block out sensitive areas from view, covering the areas with colored or black and white boxes in both live view and recorded clips. This feature is useful when users’ don’t want the sensitive information visible. Up to four Privacy Masks can be configured. 【Privacy Mask Color Settings】The Modes vary among camera models. Mode: Click Color to make the masks appear as colored rectangles on the screen.
EAN Plus Series Select All: Click to turn the whole screen into a mask area. Clear All: Click to delete all configured mask blocks. Eraser: Click to turn the mouse cursor into an eraser to delete any block you click on. Area: Shows the color and number of the block. Enable: Check this box to enable the related mask block. Click Apply to apply the settings, or click Reset to reset without saving the settings.
EAN Plus Series 7.5 Audio The EAN Plus series IP camera can transmit audio to your computer if you have connected an external microphone to its audio Input cable. It can also receive audio input from you and transmit it via an external speaker, if you have connected such a speaker to its audio Output cable. Check the Enable Audio box to enable the camera’s audio function.
EAN Plus Series 7.6 User 7.6.1 User Information The system administrator can create up to ten user accounts on this page. To set up a user account: 1. Highlight a user account and click the Modify button. The following dialog box appears. 2. Type the account name, account description and password for the account. Type the password again in the Confirm field. 3. Select an authority level for the user account from the Authority drop-down list.
EAN Plus Series • 4. 5. 6. 7. User: A user can view the Live View page and view the system, network, video, and audio information. A user can only adjust the User Config page settings. The user does not have access to the User, Event and System pages. • Guest: The lowest level of access, which only allows the user access to the Live View page. Select Active or Disable from the Status drop-down list to active or disable the user account.
EAN Plus Series 7.6.2 IP Address Filter Use this page to specify IP addresses that are not allowed to access this camera. By default, any IP address can access the camera. Note: The Allowed List addresses only become relevant when the Denied List contains a network or range, and the supervisor wants to allow one or more IP addresses within that excluded range or network. In such a scenario, the user would enter the excluded range or network in the Denied List, and enter the exceptions in the Allowed List.
EAN Plus Series 7.7 Event You can set up the Motion Detection event, Tamper Detection event or the Alarm I/O to automatically notify the users when an event occurs or an alarm is triggered. You can also set up a schedule to automatically record the videos when an event occurs or an alarm is triggered. 7.7.1 Event Settings You can create a total of ten event or alarm settings page in the Event List 【Event List】 Click the Add button, and the following Event Configuration Window appears.
EAN Plus Series Enter Event Name: Type an event name. Event Triggered by: Select an event or alarm type for the to-be-specified-below reaction/s. Alarm Input: Select this if you want a reaction trigger coming from any external, connected sensor to activate a to-be-specified-below reaction/s via the camera system. Make sure that a suitable device is actually connected to the alarm input relay.
EAN Plus Series Send Mail Notification: Click if you want the camera to send an Event notification email to the email address entered in the Set SMTP Server(email) field of the Network > SMTP/FTP page, if the Event occurs (see 7.3.3 SMTP / FTP). Upload to FTP: Click if you want the camera to upload recorded footage to the FTP server entered in the Set SMTP Server(email) field of the Network > SMTP/FTP page, if the Event occurs (see 7.3.3 SMTP / FTP).
EAN Plus Series 7.7.2 Motion Detection Use this page to configure up to four areas in which motion will be detected. When a motion is detected by the camera, the motion detection icon will appear at the top right of the Live page to alert the user. This function can also be linked with correctly configured Events to trigger Event reactions like the activation of video recording periods, snapshots, alarms, etc. Color Tabs : Click on a color tab to turn your mouse cursor into a pen of that color.
EAN Plus Series 7.7.3 Tamper Detection Use this page to set the number of seconds that an alarm signal will be active if the device is physically tampered (moved, covered up, or out of focus. 7.7.4 Alarm I/O Use this page to set the type of trigger input and the type of output contact for the camera’s alarm channel.
EAN Plus Series 7.7.5 Schedule Use this page to configure a schedule for periods during which the camera should deactivate all user-activated Events (gray Deselect periods), or when the camera should deactivate all user-activated Events, except Schedule Recording (SR) events (blue Schedule Recording-only periods), or when the camera should deactivate only SR events (red Event Recording-only periods), or when it should enable all activated Events (yellow periods).
EAN Plus Series 7.8 System You can set up the system’s time and SD card settings, and to do maintenance and reset actions like reboots and upgrades. 7.8.1 Date/Time 【Machine Name Settings】If required, enter a new name for the machine. This name will be visible in the Machine Name field of the IP Utility software, which is included in the software CD. 【Set Time Zone】Set the time zone of the camera’s location.
EAN Plus Series 7.8.2 Daylight Saving Click Enable Daylight Saving to enable this schedule, and select the dates when the region’s daylight saving period begins and ends. Click Apply to save all settings, or click Reset to cancel. 7.8.3 SD Card Use this page to prepare the system for safely removing the SD Card from its slot. 【Setup SD Card】 Notification: Select the percentage of storage space that should be left on the card before the camera notifies you of the impending storage shortage or overwrite.
EAN Plus Series 7.8.4 Maintenance 【Maintenance Server】 Reboot: Click this button to reboot the unit without changing any of the settings. Use this function if the unit is not behaving as expected. Restore: Click this button to restart and reset most of the current settings to their factory default values. The only settings that will not be changed to default are: • IP settings • DDNS settings Default: The Default button should be used with caution.
EAN Plus Series 【Save/Load Video Configuration Server】 Save: To make a backup file of the machine’s video configurations, press Save to save the video configurations to a config. file. This will enable the user to reload these configuration settings if the settings are changed and there is unexpected behavior. Load: To load a previously saved video configuration, press the Browse button to locate the saved config. file (see above) and then click the Load button.
EAN Plus Series 8. Upgrading Firmware Using IP Utility You can upgrade the Firmware using the IP Utility software included in the software CD. 1. Install and then start the IPU program . The following dialog box appears. 2. Click Find Devices to search the cameras connected in the LAN. The default network values of the cameras will be displayed. By default, the network protocol of the camera is DHCP. 3. Select a camera and click Login/Multi Login to log in the camera. 4.
EAN Plus Series 5. Highlight the camera and then click Upgrade Firmware. A browsing window appears. 6. Select the firmware file (.evb) and then click Open. The IP Utility will automatically upgrade the firmware. The camera will reboot once the update is complete. Click Find Devices, the new firmware version should be displayed in the last part of the Machine Name.
EAN Plus Series 9. Specifications Model EAN3120 Plus EAN3220 Plus EAN3300 Plus Camera 1/2.8" Sony CMOS Image Sensor 1/3" Panasonic CMOS Megapixel 1.3 MP 2 MP 3 MP Picture Elements (H x V) 1280 x 1024 1944 x 1092 2048 x 1536 Min. Illuminations 0.03 Lux at F1.4 Electronic Shutter (Sec.) 8.
EAN Plus Series Network Interface 10 / 100 Base-T Ethernet, RJ-45 socket Supported Protocols TCP/IP, IPV6, UDP, ICMP, DHCP, NTP, DNS, DDNS, SMTP, SNMP, FTP, HTTP, HTTPs, PPPoE, UPnP, Bonjour, RTP, RTSP, RTCP, IGMP, ARP, ONVIF, PSIA Connector Power DC female port / PoE Ethernet RJ-45 Audio 1 In (phone jack for microphone) 1 Out (phone jack for Speaker) Alarm I/O Terminal I/O wires Local Storage Micro SD / SDHC memory card slot TV-Out BNC socket, composite 1 V p-p / 75 Ω General Power Source
EverFocus Electronics Corp. EverFocus Taiwan: 12F, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 2380 www.everfocus.com.tw marketing@everfocus.com.tw EverFocus Europe - Germany: Albert-Einstein-Strasse 1, D-46446 Emmerich, Germany TEL: +49 2822 93940 FAX: +49 2822 939495 www.everfocus.de info@everfocus.