SINGLE FRONT DOOR INSTALLATION
Ideal Rough Opening should be 1 ½ inch wider than actual Unit Size (Net Outside Frame Size) and ¾
inch taller.
For typical wood frame construction it is also essential that the wall sheathing be a solid surface to
ensure that the unit can be secured firmly to the wall.
Rough openig should be square within a tolerance of ¼.
The oor must be level with a tolorance of 1/8.
The header must be supported by trimmer studs
Minimum double studs should be used at all wood frame rough opening
The exterior face of the rough opening must be in a single plane with less than 1/8 twist from corner
to corner.
The rough opening sill must not be crowned or sagged
Check the bottom surface of the opening to ensure it is at, level, and free from debris. Proper
operation of the door requires a sill that is at and level
Important:If these conditions are not met, the installer must take corrective actions to alter the
opening(s) before proceeding
Step1 Single Front Door Installation
Rough Opening Preparation:
Determinine prior to installation what the actual nish oor height will be and adjust the rough opening
(Existing wall opening at the Field) if needed.