User's Manual

User Manual 9
5: Terminate DMX/RDM data signal for the last DMX/RDM device in the
data run by setting the termination switch to ON (to the right, as shown
below). All other devices in the data run should retain the default
setting for the termination switch (OFF).
6: Following the label on the mounting plate, attach the power wires to
the power block.
7: Use the canopy screws to secure
the fixture to the mounting plate.
CAUTION:
Make sure that the
wiring is clear of the
mounting plate before
you secure the fixture.
Hook
2: Use the hook in the canopy enclosure to hang the
fixture from the mounting plate while you complete
the fixture wiring.
3: If desired, manually set the DMX address on the
fixture using the three addressing dials in the canopy.
See
Set the DMX Address on the Fixture
on
page 15
.
4: Connect the pre-wired DMX connector on the fixture
to the mated connector on the mounting plate
(shown below).
ON
Mounting plate
DMX connector
Termination switch
Power block
Canopy
screws