Service manual
ASR Test Procedure
xxx = # of times the test passed, yyy = # of times the test failed
e) Press
Cancel*No
to stop the test. The display shows: MIDI LOOP
f) Disconnect the MIDI cable.
*
If it fails, check the following: MIDI cable connection and digital jack board to digital board
cable.
5. Analog Page
a) Press Command, then Envl.
b)
Press the right arrow button until the display shows EXAMINE ANALOG INPUT.
c) Press
EnteraYes.
d)
Move the data entry slider to the bottom of its range.
Keyboard: The display shows: PITCHWHL 64
Rack: The display shows: PITCHWHL 0
e)
Press the up arrow button to select the appropriate input and move the selected controller
through its full range.
Keyboard:
Controller
Display
Lb
Down Center
Pitch Wheel
PITcHWHL xxx
127
0
64
Mod Wheel
MODWHEEL xxx
127
0
---
Keyboard and Rack: Plug the CVP-1 pedal into the CV jack.
CV Pedal
PEDAL xxx
127 0
---
Unplug the CV pedal and verify that display shows PEDAL 127.
Volume Slider
VOLUME xxx
127 0
---
f) When testing the Data Entry Slider, press the right arrow button so that the value is underlined.
The display shows: MR. KNOB xxx
Data Entry Slider MR. KNOB xxx
255 0
---
g)
Press the left arrow button, then the up arrow button.
Voltage Reference
REFRENCE xxx (xxx must be greater than or eaual to 190)
h) Move the Data Entry Slider to the top of its range. The display shows: R FTSW 0.
Plug the foot switch into the Ft. SW . jack. Press the RIGHT foot switch down. The display
shows: R FI’SW 127
i) Press the down arrow button. The display should show: L FISW 0. Press the LEFT foot
switch down: The display should show: L FISW
127
j) Press the down arrow button. The display should show: R PTSEL 0
Plug the foot switch into the Patch Select jack. Press the Right Patch Select foot switch down:
The display should show: R PTSEL 127
k)
Keyboard only: Press the Right Patch select button. You should get the same display message
as you did with the foot switch.
1) Press the down arrow button. The display shows: L PTSEL 0
Press the Left Patch Select foot switch down. The display shows: L PTSEL
127
m) Keyboard Only: Press the left patch select button. You should get the same display message as
you did with the foot switch.
n)
Unplug the Patch Select foot switch and Foot switch cables,
36