5
Configure the SA-G+ to talk to the
Enfora Server
4. Connect and verify Serial connectivity with the Enfora SA-G+.
v. Connect the PC serial connector to the SA-G+ serial port.
Note: In the following instructions, <CR> means using the Enter Key
on the keyboard
With HyperTerminal open, hit the Enter key. The SA-G+ should respond with OK. If
you do not see this response, double-check your connections.
w. Type AT<CR>. The SA-G+ should respond with OK. If you do not see
the letters AT, send the following command to the SA-G+: ATE1<CR>
x. Type ATI<CR>. The SA-G+ should respond with Enfora, Inc. If you get
any different response, you are not connected to the Enfora SA-G+.