Brochure
Model EPC 1600 -12 EPC 1800-24 EPC 2000-12 EPC 3000-12 EPC 3500-24
INVERTER STAGE
Output power
1)
Pnom 1300W 1400W 1800W 2600W 2800W
P10minutes 1600W 1800W 2100W 3200W 3800W
Psurge 2500W 3000W 4000W 5000W 6500W
Output voltage / frequency 230VAC ± 2% / 50Hz ± 0.05%
Output waveform True sinewave (THD < 5%
1)
) @ Pnom)
Input voltage (± 3% tolerance): Nominal 12V 24V 12V 12V 24V
Range 10.5
2)
– 16VDC 21
2)
– 32VDC 10.5
2)
– 16VDC 10.5
2)
– 16VDC 21
2)
– 32VDC
Maximum eciency 92% 94% 92% 92% 93%
No load power consumption
3)
[ASB] < 10W [2.0W] < 12W [2.0W] < 20W [3.5W] < 20W [3.5W] < 20W [4.0W]
CHARGER STAGE
AC input voltage 185 – 270VAC / 45 – 65Hz / PF > 0.95
Maximum continuous charging current
4)
60A 35A 80A 120A 70A
Standard charge voltage (bulk / oat @ 25°C) 14.3V / 13.3V
(programmable)
28.6V / 26.6V
(programmable)
14.3V / 13.3V
(programmable)
14.3V / 13.3V
(programmable)
28.6V / 26.6V
(programmable)
Charge algorithm or program IUoUoP, intelligent 4 stage, temp. comp.
AC TRANSFER SWITCH
Maximum continuous current 16Arms 30Arms
Transfer time (typical)
0ms (inv. g mains) / < 5ms (mains g inv.)
GENERAL
ePRO Link enabled Yes
Protections
high/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage
DC connections Two wires, length 1.5 meters, 35mm
2)
M10 bolt terminals
AC connections Screw terminals
Enclosure body size 351 x 210 x 114mm 370 x 431 x 132mm
Total weight 10.7kg 18.5kg
Protection class / Oper. temp. / Storage temp. IP21 / -20°C .. +50°C / -40°C .. +80°C
Standards Complies with IEC 60335-2-29 including Australian deviations.
Note : the given specications are subject to change without notice.
1) Measured with resistive load. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of approx. 1.2%/°C starting from 25°C.
2) Undervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.
3) Measured at nominal input voltage and 25°C
4) At higher ambient temperatures, maximum output current shall be reduced automatically
combi
INCLUDED AND OPTIONAL ACCESSORIES
48v 3500w ePRO Combis will be available in 2015
Dealer:
Ph: 1300 851 535
|
Unit 11, 1029 Manly Road Tingalpa, Queensland, Australia 4173
|
Email: sales@enerdrive.com.au
|
www.enerdrive.com.au
Link Cable (Windows
Connect) Optional
Temperature Sensor Included
Remote Control and Cable Optional