Manual

Lithium Battery charging algorithm
Time out 7 daysTime out 8 hrs max
Program (Power Supply) Type
Parameters below are required for setting:
Supply Voltage 13.3, 13.5, 13.7 Vdc
Maximum available current (see table)
The following table shows the programmable voltage and the maximum
current setting.
Model Program Output Voltage Setting Max. Current
EN31220 13.3V/13.5V/13.7V 20A/15A/10A/5A
EN31240 13.3V/13.5V/13.7V 40A/20A/10A/5A
EN31260 13.3V/13.5V/13.7V 60A/40A/20A/5A
EN32430 26.6V/27.0V/27.4V 30A/20A/10A/5A
Procedure To Equalise Flooded Battery
DANGER Explosion hazard and risk of battery damage.
The battery generates explosive gases during equalisation. Follow all the
battery safety precautions listed in the manual.
When using the equalisation mode, the user has to be sure the battery
connected to the channel is a ooded battery type. Equalizing a non-ooded
battery may overcharge the battery and may cause the battery to explode.
Battery Current Battery Voltage
13.3VDC triggers
Bulk Restart
Page 27www.enerdrive.com.au