Instructions

ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
3
2
1
4
5
ESD-9950-N
SET
°C
°F
P
O1
O2
+ -
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
+
°C
°F
P
O1
O2
++
S
Note1: PID control parameters ( , , , , ,
) are not seen when parameter s set as .
Note2: On Off control parameters ( , ) are not seen
when output control type parameter ( ) s set as .
Note3: Alarm parameters ( , , , , , )
are not seen when output type parameter ( ) s set as .
Note4: Alarm parameters( , , , , ) are not
seen when alarm type parameter ( ) s set as .
Note5: If s dfferent from and user enters on password
screen, parameter values are observed but can not be
changed.
Access, Change and Record the Parameter Values
Note : If no operaton for 20 seconds on Parameters Screen, devce automatcally return Man Screen .
Instructon Manual. ENG ESD-9950-N 01 V05 05/18
Front Panel Defnton
Temperature Unt Indcator
Programmng Mode Indcator
Status of Control Output 1 (Relay)
Status of Control Output 2 (SSR)
Encoder Button
ESD-9950-N TEMPERATURE CONTROLLER
ESD-9950-N Temperature Controller
- 4 dgts dsplay
- Temperature sensor nput (TC / RTD)
- Adjustable Process Offset Value
- Programmable ON/OFF, P, PI, PD ve PID control types
- Adaptaton of PID coeffcents to the system by Auto Tune/Self Tune
- Programmable control and alarm functons for control outputs
ESD-9950-N temperature controllers are desgned for measurng and
controllng a temperature value n ndustry. They can be used n many
applcatons wth ther TC and RTD temperature measurement nput, mult-
functon control outputs, programmable control and alarm functons.
They are manly used n glass, plastc, petro-chemstry, textle, automotve and
machne producton ndustres. Accurate and advanced controllng s
performed wth selectable ON-OFF, P, PI, PD, PID, Self Tune PID, Auto Tune
PID functons.
SPECIFICATIONS
INPUT
Process Input: TC/RTD
Thermocouple (TC): J, K, R, S, T and L (IEC584.1)(ITS90)
Thermoresstance (RTD): Cu-50 and Pt100 ( IEC 751) (ITS90)
Measurement Range: Please refer to parameter n parameters secton.
Accuracy: ± 0.25% of scale for thermocouple and thermoresstance.
Cold Juncton Compensaton: Automatcally ±0.1°C/1°C
Lne Compensaton: Maxmum 10 Ohm
Sensor Break Protecton: Upscale
Samplng Cycle: 0.1 second
CONTROL
Control Forms: ON/OFF, P, PI, PD veya PID (Control form can be
programmed by the user.)
OUTPUT
Process Output: Relay(7A@250VV at resstve load) or SSR Drver Output
(Maxmum 10mA, Max. 17VZ )
Alarm Output:Relay (7A@250VV at resstve load)
DISPLAY
Temperature Dsplay: 16 mm Red 4 dgts LED Dsplay
Led Indcators: O1 (Relay Process Output Status LED), O2 (SSR Process
Output Status LED), P(Programmng Mode LED),S(Set Value LED),ºC, ºF LEDs
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operatng Temperature: 0...50ºC
Humdty : 0-90%RH (none condensng)
Protecton Class: IP65 at front , IP20 at rear
Weght: 350 gr.
Dmenson: 96 x 96 mm, Depth: 100 mm
Panel CutOut: 92 x 92 mm
SUPPLY VOLTAGE
230VV (±15%) 50/60Hz - 3VA
115VV (±15%) 50/60Hz - 3VA
24VV (±15%) 50/60Hz - 3VA
Must be determned n order.
Panel Mountng
Electrcal Wrngs
To reduce the effect of electrcal nose on devce, low voltage lne (especally sensor
nput cables) wrng must be separately from hgh current and voltage lne. If
possble, use shelded cable abd sheld must be connected to ground only one sde.
Panel Cut-out
92 mm / 3.62 nch(mn)
92 mm / 3.62 nch(mn)
129 mm / 5.08 nch(mn)
129 mm / 5.08 nch(mn)
Note : If no operaton for 10 seconds, devce automatcally exts from Set Value Screen wthout savng the value.
Access and Change Set Value
Press encoder button
to observe the set value.
Turn left encoder button
to decrease or turn rght
to ncrease the set value.
Press encoder button
to save new set value
and return the man screen
ESD-9950-N
ESD-9950-N
Man Screen
ESD-9950-N
Man Screen
ESD-9950-N
Set Value Screen Set Value Screen
Press encoder
button
durng 5 seconds.
Approve password
wth encoder button.
Enter the password
wth encoder button.
Turn left encoder button
to decrease or turn rght
to ncrease value.
If no prvacy lock dentfcaton
Parameters Screen wll be
observed. If prvacy lock s
dentfed, wll be
observed. Press encoder button
to access Password Screen.
ESD-9950-N
SET
Man Screen
SET
Password Screen
SET
Password Screen Parameters Screen
If Parameters Screen is
active, "P" led blinks. To
observe previous
parameter, turn encoder
button left. To observe
next parameter, turn
encoder button right.
Press encoder button to
observe parameter value.
Parameters Screen
ESD-9950-N
Parameters Screen
ESD-9950-N
Parameters Screen
ESD-9950-N
Parameters Screen
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Turn encoder button
left to observe
previous parameter or
turn right to observe
next parameter.
Press encoder button
to observe
the parameter value.
ESD-9950-N
Parameters Screen
To increase parameter
value, turn encoder
button right. Press
encoder button to save.
To decrease parameter
value, turn encoder
button left. Press encoder
button to save.
Dmensons
96 mm / 3.78 nch
96 mm / 3.78 nch
84 mm / 3.31 nch
11.5 1mm / 0.45 nch
Maxmum 15 mm / 0.59 nch
1- Before mountng the devce n your panel,
make sure that the cutouts s of the rght
sze.
2- Check front panel gasket poston.
3- Insert the devce through the cutout. If the
mountng clamps are on the unt, put out
them
before nsertng the unt to the panel.
4- Insert the mountng clamps to the two of
desgnated holes that located on four sdes
of devce.
5- Drag the mountng clamps n drecton 5
untl the devce completely mmoble wthn
the panel.
6- In order to remove devce push on the
mountng clamp as shown wth arrow 6 and
pull back.
Parameter Values Screen Parameter Values Screen
Temperature Unt Indcator
Set Value Indcator
SETSET
°C
°F
P
O1
O2
+
++
S
SET
°C
°F
P
O1
O2
+
++
S
SET
°C
°F
P
O1
O2
+
++
S
SET
SET
°C
°F
P
O1
O2
+
++
S
Relay Output
TC
PT-100
4
5
10
11 12
13
14
15
7A@250VV
6 7 8 9
NCCNO
-
+
10mA@17VZ
SSR Drver
Output
ESD-9950-N
CAT II
O2
(Process
Output 2)
O1
(Process Output 1
or
Alarm Output)
Process Input
(Analog Input)
Supply
Voltage
Supply
Voltage
Swtch
N
L
1A T
Fuse
N
L

Summary of content (2 pages)