Operation Manual

53
|
ENGLISH
9.3.1 Register the window/door sensor
Make sure the sensor and the magnet are located next to each other.
Enter the password and press
button on the control panel.
The LED will turn on. Now separate the magnet from the sensor. The sensor will
be triggered. If you hear a beep the sensor is registered to the system. If you hear
2 beeps this indicates this sensor is already registered.
10.0 Technical specifications
10.1 Alarm system
Power supply
110 240V AC 50-60Hz
Output
12V DC 500mAh
Mobile GSM frequency
850 / 900 / 1800 / 1900Mhz
Stand-by current
110mA
Alarm current
340mA
Back-up battery
Lithium-Ion battery 3,7V 800mA BL-5B (2x)
Internal siren
110dB
Maximum amount of sensors
10 x Remote controls
50 x Sensors
50 x RFID-Tags
Sensor frequency
433MHz
Temperature
-10 to 55 degrees Celsius
Humidity
< 80% (no condensing)
Dimensions
188 x 132 x 26 mm
10.2 Motion detector
Power supply
3V DC (2 x AA 1,5V LR6)
Stand-by current
<90uA
Alarm current
<9,5mA
Detection reach
8 meter / 110 degrees
Wireless reach
Max. 80 meter (open field)
Frequency sensors
433MHz
Temperature
-10 to 55 degrees Celsius
Humidity
< 80% (no condensing)
Dimensions motion detector
108 x 52 x 36,8 mm
Dimensions mounting bracket