2018 ELLA OUTWARD SWING DOOR WALK IN BATHS OWNERS MANUAL REPRESENTING THESE MODEL NUMBERS: OA3052 Malibu OA2660 Lounger OA3252 Monaco OAL3052 Transfer O2SA3060 Tub4Two IMPORTANT Warranty Activation Form MUST be completed for both the Owner and Installer to validate the warranty. Failure to complete both pages will void the warranty on this bathtub. Completed Ella Warranty Activation Forms can be emailed to warranty@ellasbubbles.com, faxed to 312.666.3551, OR mailed to 2101 S. Carpenter St.
Table of Contents Unpack and Inspect.......................................................................................................................................... 1 Move your Ella Walk in Bath............................................................................................................................. 2 Important Safety Instructions........................................................................................................................ 3-4 Before Installation......
Unpack and Inspect NOTE: Returns are only accepted in original packaging used for shipping. Use caution so as not to damage cardboard crate or its wooden pallet. Do not dispose of shipping material until installation is complete. Please visit our website, www.ellasbubbles.com for complete details of return/exchange policy. www.ellasbubbles.
Move your Ella Walk in Bath •Remove all four (4) access panels before moving the tub •Take off the screw caps •Unscrew the screws with a Philips head screwdriver •Remove the end access panel Large Access Panel (1) Small Access Panel (2) End Access Panel (4) White Screw Caps Screw Toe Kick Access (3) Washer Cap - Access to parts - Option to lower the Threshold WARNING: Do not carry the walk in tub by the panels.
Important Safety Instructions WARNING: ***Read through the entire manual completely before beginning installation.*** Contract a licensed plumber and electrician for installation. Be sure you and your contractor are aware and follow all local plumbing and electrical codes. Your Ella Walk in Bath is not intended for outdoor use. Install the tub in accordance with the instructions in the manual. Use ONLY the parts and accessories provided or as recommended by the manufacturer.
Important Safety Instructions Continued PLEASE READ BEFORE BEGINNING INSTALLATION WARNING: Please make sure the floor drain screw is adjusted to the optimum height to close off the floor drain opening. Tighten securely with the back nut. If the screw is not tightened it can fall inside the drain and get lost. WARNING: To prevent stripping the PVC threads, ONLY hand tighten the drain elbow. DO NOT tighten with tools. www.ellasbubbles.
Before Installation Protecting the Bath Cover and protect the bath shell and fixtures from scratches or other damages during the installation and tests. Remove the access panels when moving the Walk in Bath and always lift the bathtub from the frame (Page #2). Water Test Fill tub for a minimum of 20 minutes to test that the Hydro and Air Pumps are functioning properly before final in-wall installation to avoid unnecessary repairs or removal.
Drain and Plumbing Make sure that the drain rough in has been placed at the proper location. The specifications and drawings shown below and on page #7 are demonstrative (each model comes with separate specifications, please refer each model's specification). The dual drain can be connected with a “T” or “Y” connection into existing house drain. Proper materials must be used based on local plumbing code requirements. NOTE: Flexible drains are not permitted in some areas.
Preparing the Sub-floor Prepare the sub-floor for the drain and ensure that the area is level. The supporting sub-floor must be able to support the total weight of the bathtub, bather and water. Use a level and make sure that the sub-floor below the tub is leveled. If the floor is not perfectly level, adjust the appropriate leveling legs to re-align the tub to perfect level.
Service Access and Ventilation It is the responsibility of the installer or owner to provide access for service required, per code. Ella is not responsible for any costs related to obtaining access for repair. The owner shall assume responsibility for such costs, and if appropriate, must seek recovery from the installer. Do not insulate around the tub equipment. The tub, frame and all parts have been engineered to provide the proper ventilation.
www.ellasbubbles.com Page 9 Out To Hydro Jets Hydro Pump In-Line Water Heater 5.5 A 650 W To Electrical Plug Software and Control Box Ozone Out to Hydro System Electrical Cord Ozone Generator Air and Water Dual Massage Electrical Connection with LED Light, Ozone, and Digital Control Water In Hydro Jets Out Air Pump 110-120 V 4.
www.ellasbubbles.com Electrical Switch Out Air Hose To Hyrdro Jets On/Off Push Control Hydro Pump 5A In-Line Water Heater 110v. A/C Hydro Massage System Diagram with In-Line Water Heater Out Heater Water In To Hyrdro Jets 5.
www.ellasbubbles.
www.ellasbubbles.com Out To Hydro Jets Page 12 Hydro Pump 120 V 5A LED Light 120 V .4 A Software and Control Box Out Water In To Hydro Jets 650 W 5.5 A In-Line Water Heater Electrical Plug Ozone Out to Hydro System Electrical Cord Ozone Generator Air and Water Dual Massage Electrical Connection with LED Light, Ozone, and Push Control Air Pump 110-120 V 4.
Heated Seat and Backrest (Optional Feature) Controller Box Seat and Backrest Heater LED Push Keypad www.ellasbubbles.
Water Supply Lines Ella Hydro Massage Walk in Baths with the Standard Ella Faucet (Thermostatic Control Valve) include two 4 ft. long 1/2” I.P.S. connection flexible water supply lines. Please note: The 5-Piece Fast Fill Roman and 5-Piece Traditional Roman Fauce Sets do not include the I.P.S. connection flexible water supply lines.
Installation of Spout ALWAYS INSTALL SPOUT BEFORE THE WALK IN BATH IS IN PLACE. Parts List: Rubber gasket x (1) Rubber washer x (1) Brass mounting nut x (1) Pull Out Hand Shower Mixing Control Valve Spout Hand Mixer Diverter Diverter Spout Spout Rubber Gasket Tub Shell Rubber Washer Nut Hot Cold Spout Water Line To Install the supplied spout, first place the rubber gasket on the bottom of the spout and make sure it is properly seated in its groove.
Finishing Installation After all of the water and electrical testing is completed and all fixtures are checked, the tub can be installed to the surrounding wall or walls. Ella Walk in Baths come with low rise tile flange which allows for two or one wall installations. Stud Stud Stud Drywall Drywall Drywall Glue Glue Glue Tile Tile Tile 5/8”Tub Lip Caulking 5/8”Tub Lip Caulking Caulking 5/8”Tub Lip The tub can be finished and tiled over as shown in images.
Operating Instructions 1. Thermostatic Control Valve: Before turning on the water, please adjust the thermostatic control valve to the desired water temperature. To raise the temperature above the preset 100.4 Fahrenheit, press and hold in the button handle while turning. For hotter water turn counterclockwise. Conversely, turn the valve clockwise for colder water. The thermostatic control valve is pre-set to 100.4 Fahrenheit for your safety. Button Handle Round Knob * *The button knob stops here at 100.
Operating Instructions Continued 5. Using the Hydro Massage: To activate and deactivate the hydro massage pump, push the on/off the control button (Page #9). There are two types of hydro jets in your walk in bath; adjustable and nonadjustable types. Simply push on the head of an adjustable jet and turn the head in the desired position. The in-line water heater will activate with the Hydro pump. An air flow rate control dial can be found over the shoulder of the seating area.
Cleaning and Maintenance Recommended Acrylic Cleaners Use only cleaning products whose labels state that they are SAFE for ACRYLIC. Always test products on a small are of skirt before applying to complete bath area. DO NOT USE the following on your ACRYLIC Bath System. The use of the following chemicals will cause a dull surface or chemical cracks. The use of these products will VOID YOUR WARRANTY.
TOUCHSTONE Dual Load Controller CIMC-296-01-01-01 (15 Amp) CIMC-296-01-02-01 (20 Amp) Configuration #1 Single Speed Pump Variable Speed Blower Owner’s Manual NuWhirl Systems Corp • www.nuwhirl.
Important Safety Instructions PLEASE READ CAREFULLY PRIOR TO Troubleshooting and Servicing Electrical Equipment Definitions: WARNING (May cause serious injuries or death) CAUTION (May cause property damage) For information on NuWhirl Instructions, see: www.nuwhirl.com/docs/product-instructions.html When installing and using this electrical equipment, basic safety precautions should always be followed, including: WARNING: Keep dry. Replace control if exposed to water, moisture or contamination.
TOUCHSTONE Dual Load Bath Control System Configuration #1 Owner’s Manual Your whirlpool bathtub has been equipped with TOUCHSTONE Electronic Controls to provide features that allow you to customize your bathing experience to your individual preference. Please familiarize yourself with the features and operating instructions below in order to maximize the enjoyment you receive from your bath.
Air Button Operating Instructions Single Speed Pump (Water): The Whirlpool Water System is activated by pressing the Water Button. Ensure first that there is sufficient water in the Tub to at Water least cover the Jets. (If not, the Water Detection Function will prevent the Pump from starting dry). This will turn on the Pump, and activate its 20-minute timer. The Whirlpool Water System will stop automatically when its timer expires.
TOUCHSTONE Dual Load Bath Control System Configuration #1 Owner’s Manual Electronic Keypad Operating Instructions Keypad Backlighting: When in Standby, the keys are not lighted. When in use, Blue keys indicate "No Water Detected", and Green keys indicate "Water Is Detected". When a function is in use, its key will light Red. When a fuction is off, its key will light Blue or Green as noted above. Single Speed Pump (Water): The Whirlpool Water System is activated by pressing the Water System Button.
Plug located on TOP Female Cord CCBL-372 Page 6 2. The combined rating of both Loads must not exceed the Controller’s s Amperage Rating. 3. Connect cables to ports as shown. Installation may not require the use of all connection ports. Failure to connect cables to ports as shown, may damage the control box and its components. CCBL-366 x2 daisy chained or CCBL-376 “Y” Splitter Male Cord Female Cord Plugs located on REAR CCBL-143 Conductive Water Detect Electronic Keypad Option 1.
Ella Acrylic Walk In Bath Warranty Information This limited lifetime warranty is extended to the first purchaser to be free from defects in workmanship and material under normal use and conditions from the date of the original purchase. This warranty is nontransferable and applies only to the original owner and to the original installation place – address only and does not extend to products previously used as display models or products that have been modified or repaired by anyone else but Ella’s Bubbles.
Warranty Activation Form 1 of 2 INSTALLER'S INFORMATION ________________________________________________________________________________________ Name ________________________________________________________________________________________ Address City State Zip __________________________________ Telephone __________________________________________________ Email __________________________________ Date __________________________________________________ Signature Upon completing the installation of an
Warranty Activation Form 2 of 2 OWNER'S INFORMATION ________________________________________________________________________________________ Name ________________________________________________________________________________________ Address City State Zip __________________________________ Telephone __________________________________________________ Email __________________________________ Date __________________________________________________ Signature Model: ____________________________________