Specification Sheet

Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model VRCTL8SC
®
ROUGH-IN DIMENSIONS
Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2007 Elkay
12-47B (Rev. 7/07)
INSTALLER PLEASE NOTE:
IMPORTANT
THIS WATER COOLER HAS BEEN DESIGNED AND BUILT TO PROVIDE WATER TO THE USER
WHICH HAS NOT BEEN ALTERED BY MATERIALS IN THE COOLER WATERWAYS. THE
GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING
BUT MAY ALSO OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
ELECTRICAL FEEDBACK INTO A WATER COOLER CREATING AN ELECTROLYSIS WHICH
CREATES A METALLIC TASTE OR CAUSES AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY INSTALLING THE COOLER USING THE PROPER
MATERIALS AS SHOWN BELOW.
NOTICE
THIS WATER COOLER MUST BE CONNECTED TO THE WATER SUPPLY USING A DIELECTRIC
COUPLING. THE COOLER IS FURNISHED WITH A NON-METALLIC STRAINER WHICH MEETS
THIS REQUIREMENT. THE DRAIN TRAP WHICH IS PROVIDED BY THE INSTALLER SHOULD ALSO
BE PLASTIC TO COMPLETELY ISOLATE THE COOLER FROM THE BUILDING PLUMBING SYSTEM.
MINIMUM 40 PSI SUPPLY LINE PRESSURE REQUIRED IN SPECIAL CIRCUMSTANCES WHEN BOTH
SIDES OF BILEVEL ARE IN USE SIMULTANEOUSLY TO ENSURE ADEQUATE STREAM HEIGHT. DOES
NOT APPLY TO NON-REFRIGERATED UNITS.
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
BY OTHERS
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
RIM
HEIGHT
ORIFICE
HEIGHT
ORIFICE
HEIGHT
C
L
C
L
F
D
F
E
E
A
HANGER BRACKET
FINISHED FLOOR
5/16" (8mm)
(10 HOLES)
B
C
13-7/8"
(351mm)
20-3/8"
(518mm)
2-7/16"
(62mm)
10"
(254mm)
5"
(127mm)
1-1/2"
(38mm)
37-1/2"
(952mm)
6-1/2"
(166mm)
12-5/16"
(313mm)
18-5/8"
(473mm)
8"
(203mm)
6-3/4"
(173mm)
1-3/8"
(35mm)
1-3/8"
(35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
1-3/8"
(35mm)
1-3/8"
(35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
18-1/16"
(459mm)
20-1/8"
(511mm)
4-1/2"
(114mm)
5"
(127mm)
18-3/4"
(476mm)
25-1/8"
(638mm)
32-15/16"
(837mm)
39-1/2"
(1003mm)
2-5/8"
(67mm)
27"*
(686mm)
3-1/2"
(89mm)
4-3/4"
(121mm)
31-7/8"
(810mm)
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN.
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*
ADA REQUIREMENT
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER