Installation Sheet

(L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A
Page 7
98982C (Rev. T - 01/19)
REMOVAL OF BOTTLE FILLER FOR SERVICING
1) Turn o󰀨 the water supply to the Water Coolers. Unplug and/or turn o󰀨 Circuit Breaker to Cooler(s) and Bottle Filler. NOTE: the Lower Front Panel of the coolers
may need to be removed. To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it.
2) Loosen but DO NOT remove the Pinned Torx Head Screw from the outer side of the Bottle Filler and loosen but DO NOT remove the 1/4” hex. head bolt from
between the two cooler (See Figs 7 or 8). Remove the two (2) Pinned Torx Head Screws from the Top Cover & remove the Top Cover. The Bottle Filler may then be
lifted up and o󰀨 the Water Cooler (The water line will still be connected from the Water Cooler to the Bottle Filler.)
STANDARD TWO-LEVEL CONFIGURATION
STANDARD TWO-LEVEL REVERSED CONFIGURATION
Fig. 7
Fig. 8
1/4” HEX. HEAD BOLT THIS LOCATION ONLY
1/4” HEX. HEAD BOLT THIS LOCATION ONLY