Installation Sheet
(L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A
Page 4
98982C (Rev. T - 01/19)
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE
PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU
MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SORTIE D’EAU. STUB 2 HORS DU MUR
C = 1-1/2 TRAP NOT FURNISHED
PURGADOR DE 1-1/2 NO PROPORCIONADO
SIPHON 1-1/2 NON FOURNI
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
**Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
FIG. 2
(L)VRCTL8
* ADA REQUIREMENT
* REQUISITO DE A.D.A.
* EXIGENCE ADA
OPTIONAL
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
13 7/8
352mm
18 3/4
476mm
20 1/8
511mm
25 1/8
638mm
11/16
18mm
3 1/2
89mm
4 1/2
114mm
6 1/4
159mm
5
127mm
2 1/2
63mm
10
254mm
20 3/8
518mm
2 9/16
65mm
7 1/4
185mm
3/4
18mm
4 1/2
116mm
F
A
E
D
B
F
E
18 1/2
470mm
1 1/4
32mm
1 1/4
32mm
7
178mm
16 5/16
414mm
18 1/16
459mm
1 3/8
34mm
5 3/4
146mm
5 3/4
146mm
1 3/8
35mm
37 1/2
953mm
6 1/2
165mm
O
5/16
8mm
HOLES (5)
1/4" x 1/2"
(6mm x 13mm)
OBROUND HOLES (5)
FINISHED FLOOR
FILTER
C
8
203mm
6 3/4
172mm
12 5/16
312mm
4 1/8
105mm
27
686mm
ADA
REQUIREMENT
31 13/16
808mm
RIM HEIGHT
33
838mm
ORIFICE
HEIGHT
39 9/16
1005mm
ORIFICE
HEIGHT
51 1/8
1299mm
HANGER
BRACKET
48
1220mm
2 5/8
66mm
1 1/2
37mm
18 11/16
474mm
FILTER
FINISHED FLOOR
7
178mm
5 1/8
131mm
*
*