Installation Sheet

Page 3
98980C (Rev. A - 4/12)
LVRCDWS*A LVRCTLDDWSC*A LVRC8WS*1A LVRCTL8WSC*1A
C
L
C
L
13-7/8"
352mm
18-3/4"
476mm
20-1/8"
511mm
25-1/8"
638mm
5"
127mm
2-7/16"
63mm
10"
254mm
20-3/8"
518mm
37-1/2"
952mm
2-9/16"
65mm
7-1/4"
185mm
6-1/2"
165mm
11/16"
18mm
4-9/16"
116mm
O
5/16"
8mm
HOLES
(5 PL)
FINISHED FLOOR
F
A
E
D
B
F
E
C
6-3/4"
171mm
12-5/16"
313mm
33-1/16"
840mm
ORIFICE
HEIGHT
39-9/16"
1005mm
ORIFICE
HEIGHT
HANGER
BRACKET
1/4" X 1/2" (6mm X 13mm)
OBROUND HOLE (5 PL)
27"
686mm
*
48"
1219mm
2-5/8"
67mm
18-9/16"
472mm
5-1/8"
131mm
4-1/8"
105mm
51-1/8"
1298mm
31-15/16"
811mm
RIM HEIGHT
8"
203mm
18-1/16"
459mm
7"
178mm
7"
178mm
1-1/4"
32mm
1-1/4"
32mm
16-5/16"
414mm
O
5/16"
8mm
HOLES
(3 PL)
5-3/4"
146mm
5-3/4"
146mm
1-3/8"
35mm
1-3/8"
35mm
18-1/2"
470mm
3-1/2"
89mm
4-1/2"
114mm
6-1/4"
159mm
Single Rough-In
Fig. 1
LVRCTL8WS
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL.