Specification Sheet

Vandal-Resistant EZH2O
®
Bottle Filling Station
with Single Filtered Vandal-Resistant Cooler
Models LVRC8WS & LVRCDWS
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
ROUGH-IN DIMENSIONS
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been
altered by materials in the cooler waterway. The grounding of electrical equipment
such as telephone, computers, etc. to water lines is a common procedure. This
grounding may be in the building buy may also occur away from the building.
This grounding can cause electrical feedback into a water cooler creating an
electrolysis which results in a metallic taste or an increase in the metal content
of the water. This condition is avoidable by installing the cooler using the proper
materials as shown.
NOTICE:
This water cooler must be connected to the water supply using
a dielectric coupling. The cooler is furnished with a non-metallic
strainer which meets this requirement. The drain trap which is
provided by the installer should also be plastic to completely isolate
the cooler from the building plumbing system.
RATED FOR INDOOR USE ONLY
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (38mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: Installations Must Use Ground Fault Circuit Interrupter. (GFCI)
Printed in U.S.A.
© 2014 Elkay
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
5
127mm
10
254mm
13 7/8
352mm
2 9/16
65mm
7 1/4
185mm
18 3/8
467mm
21 3/8
543mm
25
635mm
F
A
D
B
E
E
31
788mm
49 1/2
1257mm
18 1/2
470mm
FINISHED FLOOR
6 3/4
171mm
6 1/4
159mm
1 1/2
38mm
2 5/8
66mm
8
203mm
C
27
686mm
ADA
REQUIREMENT
31 15/16
811mm
RIM HEIGHT
33 1/16
840mm
ORIFICE
HEIGHT
18 5/8
472mm
51 1/8
1298mm
5 1/8
131mm
48
1219mm
O
5/16
8mm
MOUNTING HOLES
(3 PL)
1/4" X 1/2" (6mm X 13mm)
OBROUND HOLE (5 PL)
HANGER BRACKET
7
178mm
7
178mm
16 5/16
414mm
1 1/4
32mm
1 1/4
32mm
FILTER
2 7/16
63mm
3 1/2
89mm
4 1/2
114mm
12 5/16
313mm
4 9/16
116mm
3/4
18mm
2 1/2
64mm
FINISHED FLOOR
FILTER