Specification Sheet

FLOORLINE
CHILLER SHELF
(476mm)
(130mm)
MIN.DEPTH
(203mm)
TOFLOOR LINE
LOCATION ON CHILLER
(29mm)
(NOTPROVIDED)
(959mm)
(114mm)
FRAME
(10 REQD)-(NOTPROVIDED)
(NOTPROVIDED)
HOOKRODS(2)
FLOOR LINE
CHILLER SHELF
(476mm)
(130mm)
MIN. DEPTH
(203mm)
TO FLOOR LINE
LOCATION ON CHILLER
(29mm)
(NOT PROVIDED)
(959mm)
(114mm)
FRAME
(10 REQ’D) - (NOT PROVIDED)
(NOT PROVIDED)
HOOK RODS (2)
3
(79mm)
(29mm)
8
(206mm)
9
(238mm)
MINIMUMDEPTH
5
(16mm)
1
(467mm)
5
(140mm)
(89mm)
BACK WALL LINE
FURNISHED
1
(41mm)
(730mm)
(203mm)
(114mm)
(29mm)
(279mm)
FINISHED FLOOR
ELECTRICAL INLET
REQUIREMENT
(863mm)
(519mm)
2
(517mm)
2
(73mm)
2
(73mm)
1
(356mm)
(502mm)
3
COLD WATER OUTLET
3
W
SHUTOFFVALVE BY OTHERS
1
(25mm)
3
(79mm)
(29mm)
8
(206mm)
9
(238mm)
MINIMUM DEPTH
5
(16mm)
1
(467mm)
5
(140mm)
(89mm)
BACK WALL LINE
FURNISHED
1
(41mm)
(730mm)
(203mm)
(114mm)
(29mm)
(279mm)
FINISHED FLOOR
REQUIREMENT
(863mm)
(519mm)
2
(517mm)
2
(73mm)
2
(73mm)
1
(356mm)
(502mm)
3
COLD WATER OUTLET
3
W
SHUT OFF VALVE BY OTHERS
1
(25mm)
FIG. 2
FIG. 1
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B
C
NOTE:WATERFLOW
DIRECTION
SERVICE STOP
(NOTFURNISHED)
3/8"O.D.TUBECONNECT
COLD WATERSUPPLY
1/4"O.D.TUBE
WATERINLET
TOCOOLER
BUILDINGWATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
IMPORTANT!
INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as tele-
phone, computers, etc., to water lines is a common
procedure. This grounding may be in the building or
may occur away from the building. This grounding
can cause electrical feedback into a water cooler,
creating an electrolysis which causes a metallic
taste or causes an incre
ase in the metal content of
the
water. This condition is avoidable by using the
proper materials as indicated below.
The drain fittings which are provided by the installer
should also be plastic to electrically isolate the cooler
from the building plumbing system.
LRPBM8K MOUNTING FRAME INSTRUCTIONS
1. Cut a square rectangular wall opening 18-3/4"
(476mm) W x 37-3/4" (959mm) H and 4-1/2"
(114mm) above the floor line. These dimensions
ar
e required to obtain proper rim and bubbler
heights for compliance with ANSI standard
A117.1. (See Figure 2)
2. Reinforce the wall opening on all sides so that it
will adequately support the water fountain. This
reinforcement must support up to 150 lbs static
load and provide a means for securing the frame
assembly in place.
NOTE: Building construction must allow for ade-
quate
air flow on both sides and top of remote
chille
r unit. Minimum of 4" (102mm) is required.
(See Figures 1 & 2)
3. Install plumbing and electrical rough-ins.
See Figure 1 for location of the supply water inlet
to chiller and for the location of the waste water
outlet. A junction box for a (3) wire, 10 amp branch
circuit is provided on the inside of the chiller.
(Standard 120 Volts, 60 Hz and single phase) See
Figur
e 2 for the electrical inlet location.
4.Remove frame and related hardware from
packaging. Release the two shelf rods by cutting
cable ties. Install the frame squarely in wall
opening with frame upright edges flush with the
finished wall face. (See Figure 2) Place shelf
inside frame and line up the (2) holes on each.
Insert loose ends of rods into holes on sides of
shelf panel. Using appropriately sized wood
scr
ews (not provided), fasten the shelf and frame
to bottom of wall opening. (See Figure 2) Secure
the frame sides and top to the wall using (10)
5/16" x2" lag bolts or screws (not provided).
NOTE: Be sure that frame is squared in location.
Do not use less than the required screw quantity
and size.
2222 Camden Court
Oak Brook, IL 60523
elkay.com
Printed in U.S.A.
©2015 Elkay
Elkay
12-45E
(Rev. 12/15)
No Lead SwirlFlo
®
with WaterSentry
®
VII Filter System
Barrier-Free Access
Model LRPB(M)8K
®
®
ROUGH-IN DIMENSIONS
WaterSentry
®
VIIFilterSystem
WaterSentry
®
VII Filter System
ELECTRIC INLET