Installation Guide

T
urn off the water supply at the main source.
Handle plated surfaces with care being car
eful not to scratch with tools.
When assembling faucet after replacement, hand tighten all parts prior to tightening
with wrench. Do not for
ce parts together.
General Instructions
1. After shutting off water supply
, move handles to open position to relieve built up
pressur
e.
2. Remove handles fr
om cartridge stem.
3. Remove handle nuts if applicable.
4. Loosen and r
emove cartridges from faucet body.
5. Insert new cartridge, hot on the RIGHT side, cold on the LEFT and tor
que to
128 kg/cm. (Cartridges are installed opposite of normal configuration due to the
on/off handle dir
ection.)
6. T
urn on water supply, cycle cartridge on and off checking for leaks.
7. Install and tighten handle nuts if applicable.
8. T
urn both cartridges to the off position and properly reposition the handles, hot on
the left and cold on the right from the user position.
9. Tighten the handles and cycle the faucet to confirm pr
oper function.
For LK500C and LK945 Models
1. After shutting off water supply, move handles to open position to relieve built up
pressure.
2. Remove handles from cartridge stem.
3. Remove handle nuts if applicable.
4. Loosen and remove cartridges from faucet body
.
5. Insert new cartridge, hot on the LFET side, cold on the RIGHT and torque to
128 kg/cm.
6. Turn on water supply
, cycle cartridge on and off checking for leaks.
7. Install and tighten handle nuts if applicable.
8. Turn both cartridges to the off position and pr
operly reposition the handles, hot on
the left and cold on the right from the user position.
9. Tighten the handles and cycle the faucet to confirm proper function.
For All Other LK Models
TO REPLACE CARTRIDGE