Specification Sheet

Bi-Level, Stone Pedestal
Sanitary Freeze-Resistant,
Barrier-Free Fountain
Model LK4595SFR
®
ROUGH-IN DIMENSIONS
Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2012 Elkay
19-22B (2/12)
A
B
1-3/4"
(44mm)
15-1/2"
(394mm)
12"
(305mm)
12"
(305mm)
1/2 x 3/4 SLOT
6-3/4"
(172mm)
SEE DETAIL A
38-1/2"
(978mm)
34-1/2"
(876mm)
27"
(686mm)
19"
(483mm)
40"
(1016mm)
38-1/2"
(978mm)
4"
(102mm)
WATER INLET LINE
(BY INSTALLER)
VALVE WATER LINE 
SUPPLIED WITH A 1/4 x 
1/2 NPT CONNECTOR
DRAIN LINE BY INSTALLER
(AS REQUIRED BY 
LOCAL CODES)
LEGEND
A = ACCESS PANEL
B = REMOVABLE BOTTOM COVER
DETAIL A
AIR GAP / VACUUM BREAKER
SIDE VIEW
TOP VIEW
1-14" DRAIN TUBE
SUPPLIED W/ FTN.
AIR GAP ASSY.
SUPPLIED WITH VALVE
1-12" DRAIN TUBE
SUPPLIED BY INSTALLER
MOUNTING INSTRUCTIONS and
PLUMBING INSTRUCTIONS
Site and drainage excavation is required for fountain installa-
tion. Refer to owner’s manual for site preparation details.
Provide solid, well-drained surface to mount pedestal foun-
tain (concrete pad recommended). (4) 1/2" anchor bolts (not
included) should be attached firmly to mounting surface in
order to secure fountain. Refer to rough-in diagram and be
sure to allow an opening for the freeze-resistant valve in the
ground as shown in the installation instructions that accom-
pany the fountain. Refer to local codes for any additional
requirements.
NOTE: Fountain is not furnished with service valve. Assemble
fountain to prepared site and mounting pad.
Position pedestal over plumbing and secure base to anchor
bolts. Remove access panels and connect supply and water
lines. Turn on water supply and check for leaks. Refer to
owner’s manual for detailed instructions.
Service stop not included.
Operating Pressures: Supply water - 105 psi maximum.