Installation Instructions

Page 13 1000001734 (Rev. C - 11/14)
EZWSR*1C, *2C LZWSR*1C, *2C
Bottom View of Cooler
Fig. 13
Alternate Filter Mounting Location Fig. 14
A
B
3/16” Dia.
2 Holes
EXISTING
HOLE
1-3/8” Dia. Hole
SCREWS
PLASTIC BUSHING
SCREWS
FILTER MOUNTING BRACKET
FILTER ASSEMBLY
ALTERNATE FILTER MOUNTING LOCATION
1) Using the supplied punch from the Bottle Filler installation, punch a 1-3/8” dia. hole “A” at the existing hole shown in
Fig. 13.
2) Drill two 3/16” dia. hole at location “B” shown in Fig 13.
3) Remove Filter bracket from lter assembly and reinstall as shown in Fig. 14. Be sure the 3/8” water inlet is facing out.
4) Install plastic bushing (supplied) as shown into 1-3/8” hole, bushing must be used so waterlines will not be cut by
sharp edges of base plate.
5) Install lter assembly to bottom of cooler as shown in Fig. 14 with 2-#8 sheet metal screws.
6) Run the inlet and outlet water lines to lter.
7) P/N 98551C - LZ Filter Mounting Cover (Light Gray Granite) or P/N 98568C - LZ Filter Mounting Cover (Stainless Steel)
may be order to enclose the lter beneath the cooler (Not Shown).
3/8” WATER INLET