EZOTL8WS*1A LZOTL8WS*1A INSTALLATION & USE MANUAL Manual de instalación y uso Manuel d’installation et utilisation EZO ™& LZO™Series Sensor-Operated Versatile Bottle Filling Stations & Coolers EZO™ & LZO™ Estaciones y enfriadores de botellas versátiles operados por sensor EZO™ & LZO™ Stations de remplissage et refroidisseurs de bouteilles de la série polyvalente commandés par capteur *Versatile Cooler Model LZOTL8WSLK alternate installations *Versatile Cooler Model LZOTL8WSLK configuration as shipped *V
EZOTL8WS*1A LZOTL8WS*1A INSTALLER PLEASE NOTE: IMPORTANT This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler water ways. The grounding of electrical equipment such as telephones, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building.
EZOTL8WS*1A LZOTL8WS*1A TROUBLE SHOOTING & MAINTENANCE GUIDE PUESTA EN MARCHA 15. BUBBLER: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8” diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s). 16. Stream Regulator: If orifice is clean, regulate flow as in “START UP” instructions above.
EZOTL8WS*1A LZOTL8WS*1A Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad. Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil. Pictured is unit only without bottle filler. En la foto, la unidad sólo sin relleno botella. Sur la photo, est une unité seulement sans remplissage de la bouteille.
A PREFERRED LOCATION 5-3/4" (146mm) 7" 7" (178mm) (178mm) FINISHED FLOOR 3-9/16" (90mm) 19" (483mm) 18-7/8" (479mm) REFRIGERATED UNIT MUST BE INSTALLED ON RIGHT-HAND SIDE. LEGEND/LEYENDA/LÉGENDE D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET** SUMINISTRO ELÉCTRICO (3) CAJA ENCHUFE DE ALAMBRE SALIDA DÚPLEX ALIMENTATION ÉLECTRIQUE (3) BOÎTIER ENCASTRÉ E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
1000005926 (Rev. C - 08/21) E B 15" (381mm) 2-7/8" (73mm) 18-7/8" (479mm) Page 6 3-7/8" (98mm) D PREFERRED LOCATION 2" (51mm) 7/8" (22mm) 6-3/8" (162mm) 2" (51mm) 5-3/4" (146mm) 7" (178mm) ‰ 6-3/8" (162mm) FINISHED FLOOR 7" (178mm) 6-3/8" (162mm) 18-3/8" (467mm) 38-3/8" (975mm) ORIFICE HEIGHT NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS.
3-7/8" (98mm) A (ALT.LOCATION) ‰ 2" (51mm) 7/8" (22mm) 6-3/8" (162mm) 7" (178mm) 2" (51mm) 6-3/8" (162mm) F FINISHED FLOOR D (ALT.LOCATION) 22-15/16" (583mm) 19-7/16" (494mm) F 34-5/16" (872mm) 24-1/2" (622mm) A PREFERRED LOCATION E NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS. 1-7/16" (37mm) 18-7/8" (479mm) REFRIGERATED UNIT MUST BE INSTALLED ON RIGHT-HAND SIDE.
1000005926 (Rev. C - 08/21) Page 8 E 6-3/8" (162mm) 2" (51mm) 7/8" (22mm) 6-3/8" (162mm) B ‰ 2" (51mm) A PREFERRED LOCATION 6-3/8" (162mm) 3-7/8" (98mm) 5-3/4" (146mm) 7" 7" (178mm) (178mm) FINISHED FLOOR 6-3/8" (162mm) Ø 9/32" (7mm) (12 HOLES) 18-3/8" (467mm) 21-7/8" (483mm) NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS.
EZOTL8WS*1A LZOTL8WS*1A HANGER BRACKETS INSTALLATION 1) Remove hanger brackets fastened to back of cooler by removing one (1) screw. 2) Mount the hanger brackets as shown in Figures 2, 3, 4 or 5. NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes. INSTALLATION OF COOLER 3) Hang the cooler on the hanger bracket.
EZOTL8WS*1A LZOTL8WS*1A 11 View of Underside of Basin Shroud Vista de la parte inferior de la cuenca cubierta Vue de dessous du bassin du Saint-Suaire 26, 30 Stream Height Adjustment Location Ubicación de ajuste de altura de corriente Emplacement de réglage hauteur Stream 2B 26 11 Service Instructions 8A Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud.
EZOTL8WS*1A LZOTL8WS*1A Versatile Wrapper and Trim Kit Installation Instructions Left Hand Wrapper (High Side) 1) Remove existing wrapper by removing the (4) screws from bottom. 2) Screw trim piece to wrapper with (2) screws (provided) 3) Re-install wrapper with (4) screws. 4) Dispose of unused Right Hand Wrapper (Low Side) 1) Remove existing wrapper by removing the (4) screws from bottom. 2) Clip cover plate, sliding until plate sits flush with the wall. 3) Re-install wrapper with (4) screws.
EZOTL8WS*1A LZOTL8WS*1A 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL UNIT CENTER LINE TOP COVER Fig. 10 MOUNTING SCREWS 31 Fig. 11 BRACKET & SCREWS Fig. 12 Fig. 13 Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 11). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover. 2) Remove wall mounting plate from Bottle Filler.
EZOTL8WS*1A LZOTL8WS*1A BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE 1) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall outlet or switching off the circuit breaker to the unit.
EZOTL8WS*1A LZOTL8WS*1A INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON-REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVEL Fig. 14 Fig. 15 Using a 5/16" socket, remove the (4) screws from the bottom of each cooler to remove the wrappers. Using a #T20 (6 point star bit), loosen the shroud screws. Both sides, both coolers. ONLY move the filler panel and j-clip to the refrigerated (right) side if right side will be mounted 'high'.
EZOTL8WS*1A LZOTL8WS*1A INSTRUCTIONS CONTINUED..... Swap drain parts in shroud: Loosen each hose clamp retaining the drain pieces. Remove each drain piece and swap to other basin. Tighten each hose clamp. Fig. 18 Refrigerated Cooler side: Carefully lift and tip the shroud/basin assembly off of the cooler frame. Only disconnect the (2) black wires coming from the shroud assembly that go to the solenoid valve and to the cold control. Fig. 19 Disconnect the water line at the solenoid valve. Reference (Fig.
EZOTL8WS*1A LZOTL8WS*1A PLUMBING DIAGRAMS VERSATILE BI-LEVEL Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Fig. 22 1000005926 (Rev.
Page 17 Tee 3/8” Water Inlet Evaporator R.H. Refrig. unit regulator Bubbler Filter Assembly 1/4” Union regulator Bubbler L.H. Non-Refrig unit Tee 3/8” Water Line from Bottle Filling Unit Standard EZ Bi-Level Pressurized Plumbing Diagram Solenoid Valve 3/8” Water Inlet Solenoid Valve EZ Bi-Level Plumbing Diagram after Filter Installation & Bottle Filler Water Line Addition Solenoid Valve regulator Bubbler 3/8” Water Line from Bottle Filling Unit L.H.
EZOTL8WS*1A LZOTL8WS*1A Fig. 24 11 Basin Estanque Bassin Locknut Tuerca de Fijación Écrou de Blocage BUBBLER DETAIL DETALLE DEL GRIFO DETAIL DU BARBOTEUR Fig. 25 NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. NOTA: Al instalar el grifo y pedestal de reemplazo, apriete la tuerca unicamente para mantener las piezas en una posicion adjustada. No dede apretarse demasiado.
EZOTL8WS*1A LZOTL8WS*1A Fig. 27 2 BOTTLE FILLING UNIT WALL MOUNTING PLATE 3/8” Water Inlet 1 Filter Head Assembly used after 01/01/2021 Fig.29 Fig. 28 WATERSENTRY® PLUS Filter Detail Detalle WATERSENTRY® Filtro Description WATERSENTRY® Filtrage FILTER PARTS LIST ITEM NO. PART NO.
EZOTL8WS*1A LZOTL8WS*1A Standard Rough-In Primary Outlet Location Standard Rough-In Alternate Outlet Location Reverse Rough-In Primary Outlet Location Reverse Rough-In Alternate Outlet Location Fig. 30 1000005926 (Rev.
EZOTL8WS*1A LZOTL8WS*1A ITEM NO. PART NO.