Specification Sheets

19 7/16"
494mm
24 1/2"
622mm
19"
483mm
28 13/16"
732mm
2"
51mm
2"
51mm
18 3/8"
467mm
6 3/8"
162mm
6 3/8"
162mm
6 3/8"
162mm
6 3/8"
162mm
2"
51mm
2"
51mm
18 3/8"
467mm
O
9/32"
7mm
(12)
E
13 15/16"
354mm
21 7/8"
556mm
A
REFERRED
LOCATION
D
ALT. LOCATION
3 7/8"
98mm
7"
178mm
7"
178mm
B
F
F
D
PREFFERED
LOCATION
A
(ALT. LOCATION)
E
7/8"
22mm
FINISHED FLOOR
22 15/16"
583mm
5 3/4"
146mm
34 5/16"
872mm
1 7/16"
37mm
3"
76mm
12 1/2"
318mm
C
8 1/16"
205mm
27"
686mm
ADA
REQUIREMENT
31 5/16"
796mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE
HEIGHT
36 13/16"
936mm
RIM
HEIGHT
38 3/8"
975mm
ORIFICE
HEIGHT
HANGER
BRACKET
19"
484mm
Printed in U.S.A.
© 2014 Elkay
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
RATED FOR INDOOR USE ONLY
NOTICE
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non-metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not
been altered by materials in the cooler waterway. The grounding of electrical
equipment such as telephone, computers, etc. to water lines is a common
procedure. This grounding may be in the building but may also occur away from
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
ROUGH-IN DIMENSIONS
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
Versatile Bi-Level Wall Mount Water Cooler
Hands Free
®
Sensor & Pushbar Activated
Model EZOSTL8
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Page 3
ROUGH-IN FOR RIGHT-HAND HIGH SIDE MODELS
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Model shown with Flexi-Guard
®
bubbler.