Installation Instructions

97924C (Rev. G - 2/12)
ERPB2-8C, ERPB2-8RAC, ERPBV2-8C, ERPBV2-8RAC, LRPB2-8C, LRPB2-8RAC, ERPB2-8C*2C, ERPB2-8C*3C
ERPB2-8GRNC*A, ERPB2-8GRNRAC*A, LRPB2-8GRNC*A, LRPB2-8GRNRAC*A
Page 4
Figure 5 - Upper Panel Installation
Figure 6 - Fountain Installation
Figure 7 - Lower Panel Installation
5. Hang the upper panel on the mounting frame hanger. Be
sure that the panel is engaged with hanger at the top of
frame before releasing it. Align holes in the panel with holes
in the mounting frame. Install two (2) #10-24 x 5/8” (16mm)
screws (Item 29 - Figure 5) in holes and tighten securely.
6. Install the fountain. Remove the screw (Item 30) from cover
plate and slide cover plate (Item 14) toward basin. Mount the
fountain to the upper panel and frame with (4) 5/16” x 1”
(25mm) bolts (Item 33), brackets (Item 36) and nuts
(Item 35) provided. Tighten securely. Brackets (Item 36)
must be installed as shown to properly support
fountains. (See Figure 6)
7. Attach waste tube (1-1/4” O.D.) to 1-1/4” O.D. slip
trap (provided by others).
8. ERPB Models: Make connections between remote chiller
outlet tube and fountain. Outlet port is marked on the chiller
(1/4” O.D. copper tube). Install a 1/4” x 1/4” tee (provided)
on the marked chiller outlet port. Insert the 1/4” poly tubing
coming from the fountain into the union. Turn on the water
supply and check for leaks.
CAUTION:
DO NOT SOLDER tubes inserted
into the strainer as damage to
o-rings may result.
LRPB Models: Make connections between remote chiller
outlet tube and fountain. Outlet port is marked on the
chiller (1/4” O.D. copper tube). Install a 1/4” x 1/4” tee
(provided) on the marked chiller outlet port. Insert the 1/4”
poly tubing coming from the fountain into the union.
CAUTION: DO NOT SOLDER tubes inserted
into the strainer as damage to
o-rings may result.
9. These products are designed to operate on 20-105
PSIG supply line pressure. If inlet pressure is above
105 PSIG, a pressure regulator must be installed in
the supply line.
CAUTION: Any damage caused by connecting
these products to a supply line with
pressure lower than 20 PSIG or
higher than 105 PSIG IS NOT
covered under warranty.
10. Make electrical connections to the chiller. See
chiller instructions.
11. Check stream height from bubbler. Stream height is
factory set at 35 PSI. If supply pressure varies greatly from
this, remove push button (Item 17 - Figure 11) and adjust
the screw on the regulator (Item 19 - Figure 11). To remove
push button, remove set screw from bottom of sleeve
(Item 33). Insert a small punch in screw hole and push up
while grasping the push buttom and pull forward removing
the push button. Clockwise adjustment will raise stream height
and counterclockwise movement will lower stream height. For
best adjustment stream should hit basin approximately 6-1/2”
from the bubbler. Reassemble push button by pushing in on
button until the push button catches in the sleeve. Reinstall
the setscrew (Item 33) in the sleeve (Item 15).
12. Mount lower panel. Loosen the three (3) #10-24 x 5/8”
(16mm) screws (Item 29 - Figure 6) at frame bottom lip. Slide
upper tongue of lower panel under lower edge of already
installed upper panel. Tighten previously loosened screws
securely. (See Figure 7)
37
35
34
29, 30, 31, 32
34
28
41
40
View From Rear
16