Installation Sheet

1000002042 (Rev.D-09/15)
EMASMB*A & LMASMB*A
Page 6
SETTING THE CONTROL BOARD
VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the
unit will need to be shut down and restarted. The chiller
(if present) does not need to be shut down and restarted.
2) Shut down the unit by removing a battery.
3) Restart the unit by installing the batteries
4) Upon start up the bottle count display will show the
software designation of 'ELKAY BC'.
ACCESSING THE PROGRAMING BUTTON
1) To access the program button, remove the two (2)
screws holding the Bottom Cover in place. Button is located
within nger reach from the underside of the unit on the back
right hand side of the battery/lter tray.
2) When nished setting control board, reinstall the Bottom Cover
and secure with the same two (2) screws.
RESET THE FILTER MONITOR
1) Instructions apply to ltered units only.
2) Depress the program button momentarily.
The display changes when released. The display will
change and scroll through four messages:
“RST FLTR” – Reset Filter Status LED
“NO FLTR” – EMASMB or non-ltered mode
"500G FLT" – LMASMB or Filtered mode
"RST BCNT“ - Reset bottle count
If the program button is not pushed again the display
will scroll through the four messages above for
and then default back to bottle count and be back in run
mode.
3) When the display changes to “RST FLTR”, depress
the button again. The display will change to show
“FC RESET”. Depress the button again and the display
will show “00000000”
4) There are three (3) LED's that indicate the following:
Green: LED (Good) indicates that the lter is operating
within 0% - 80% of its life.
Yellow: LED indicates that the lter is operating within
80% - 100% of its life.
Red: LED (Replace) indicates that the lter needs to be
replaced since it has reached end of lter life.
and ow restrictions.
RESETTING BOTTLE COUNT
1) Depress the program button momentarily.
The display will change and scroll through four messages:
“RST FLTR” – Reset Filter Status LED
“NO FLTR” – EMASMB or non-ltered mode
"500G FLT" – LMASMB or Filtered mode
“RST BCNT“ - Reset bottle count
If the program button is not pushed again the display
will scroll through the four messages above for
and then default back to bottle count and be back in run mode.
2) When the display changes to “RST BCNT”, push the button
again and the display will show “BC RESET” If the button is not
pushed again the display will return to run mode.
3) Push the program button once more to reset back to 0. The dis-
play will and then return to run mode showing 00000000 bottles.
NOTE: Once the bottle count is reset to zero there is no way
to return to the previous bottle count.
4) Testing the bottle counter:
EMASMB units: Push button for approximately 9 seconds to see
bottle counter count 00000001.
NOTE: Bottle count is approximate and is dependent on water
pressure and ow through the lter. LMASMB units: Push
button for approximately 19 seconds
to see bottle counter count 00000001. NOTE: Bottle count is
approximate and is dependent on water pressure and ow
restrictions.
DESCRIPTION
1000001673
98546C
56192C
KIT-1.0 GPM REGULATOR KIT
KIT-AERATOR
KIT-FILTER REPLACEMENT KIT
REPLACEMENT PARTS
PART NO.
REGULATOR
AERATOR
FILTER
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FIGURE 3
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
BATTERY CONFIGURATION RESET SWITCH