Specification Sheet

CL
CL
18"
(457mm)
5-3/16"
(132mm)
10"
(254mm)
7-1/8"
(181mm)
7-7/8"
(200mm)
15-1/4"
(387mm)
18-3/4"
(476mm)
27"
(686mm)
34-1/8"
(867mm)
RIM
HEIGHT
FROM
FLOOR
(TRAP NOT FURNISHED)
INLET WATERLINE
AND SHUT-OFF
NOT FURNISHED
SEE DETAIL
"A"
16-3/4"
(426mm)
23-7/8"
(606mm)
ORIFICE HEIGHT
1-1/4" (32mm)
ABOVE RIM
33-1/4"
(845mm)
31-1/4"
(794mm)
5/8"
(16mm)
5-1/2"
(140mm)
4"
(102mm)
ELECTRICAL
OUTLET
LOCATION
ALT.
ELECTRICAL
OUTLET
LOCATION
3"
(76mm)
3"
(76mm)
3"
(76mm)
3-1/4"
(83mm)
1-1/2"
(38mm)
1"
(25mm)
3/4"
(19mm)
1-1/4" I.P.S. WASTE
OUTLET
3/8" I.P.S. WATER
SUPPLY
44-9/16"
(1132mm)
ALTERNATIVE
ELEC.
OUTLET LOC.
ELECTRIC OUTLET
LOCATION
1-1/2 FOOT
(457mm) LONG
POWER CORD
1-1/4" (32mm)
O.D. DRAIN
THIS BOLT HOLE MUST
BE USED FOR FASTENING
UNIT TO WALL.
CL
4"
(102mm)
DETAIL A
DETAIL B
Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2006 Elkay
12-2I (Rev. 7/06)
No Lead Wall Mount Water Cooler
Barrier-Free Access
Model EHFSA8
®
ROUGH-IN DIMENSIONS
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
BY OTHERS
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
IMPORTANT!
INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes an
increase in the metal content of the water. This condition is avoidable by installing the
cooler using the proper materials as shown below.
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely
isolate the cooler from the building plumbing system.