Specification Sheet

GENERAL
Self-contained, wall hung, electric refrigerated water cooler.
Capacity, 7.6 GPH of 50°F drinking water, based upon 80°F
inlet water and 90°F ambient.
Model has a hooded stream projector with self closing push
bars on front and both right and left sides. Built-In flow regu-
lator from 20 to 105 psi. Bubbler stream fully protected to
meet all sanitary codes.
Non-pressurized tank system is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is sub-
ject to line pressure only when push bar is pressed.
THIS WATER COOLER COMPLIES WITH THE REQUIRE-
MENTS OF A.D.A. (AMERICANS WITH DISABILITIES ACT)
WHEN PROPERLY INSTALLED.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway sys-
tem utilizing copper components and completely lead-free
material. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted. A strainer with an easily cleanable screen is pro-
vided to allow trapping and convenient removal of water born
particulate of 140 microns and larger prior to their entry into
the water cooler.
This water cooler is certified to
NSF/ANSI 61.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hertz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Self cleansing.
Tube portion is continuous coil of copper tubing. Fully insu-
lated with EPS foam which meets Underwriters Laboratories
Inc. requirements for self extinguishing plastic material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
Temperature Control: Enclosed adjustable thermostat is fac-
tory pre-set. Requires no adjustment other than for altitude
requirement.
Model EHFSA8
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2006 Elkay
(Rev. 7/06) 12-2I
elkayusa.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
** Patent #4,481,971
Elkay Electric Air Cooled Water Coolers meet the
requirements of NSF/ANSI 61. Unit complies with
A.R.I. Standard 1010.
No Lead Wall Mount Water Cooler
Barrier-Free Access
Model EHFSA8
®
SPECIFICATIONS
CONSTRUCTION
Frame: #16 gauge galvanized steel chassis supports fountain
top and all working mechanisms. No operating parts are con-
nected to cabinet panels.
Fountain Top and Backsplash: One piece stainless steel top,
polished to a uniform Elkay satin luster finish. Basin has
removable perforated drain grid, embossed bubbler pad.
Exclusive Flexi-Guard
®
Safety Bubbler*: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer to
prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Anti-
sweat. Keyed in location to prevent rotation.
Color Selection: Light Gray Granite vinyl furnished as stan-
dard unless alternate panel color is selected. Alternate panel
colors in vinyl are: Sandalwood, and Natural Almond. All fur-
nished at no extra cost. Stainless Steel units available at extra
cost.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are war-
ranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
CAPACITIES CHART
*Based on 80°F inlet water temperature. Glass filler available at extra cost.
Requires factory preparation to receive glass filler. Glass filler LK109a can be
furnished.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
*GPH of 50°F Drinking Water
Full Glass Ship.
Model Base
Room Temperature °F
Rated Load Filler Wt.
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
EHFSA8 7.6 9.2 8.4 7.6 370 4.0 YES 70