Installation Sheet
Page 1 98526C (Rev. K - 06/19)
WaterSentry Plus Retro Bottle Filler and Water Cooler
7a. Turn on water supply and hold open the bubbler on cooler
untilapproximately1gallonofwaterisdispensed.Thisushing
procedurepurgesairandnecarbonparticlesfromthelter.
When 1 gallon of water has been purged through the cooler,
carefully inspect all water connections for leaks.
Theselterkitsaredesignedtobeusedwiththefollowing
Elkay products.
Filtered EZH2O
®
Bottle Filling Station Models
Examples include but not limited to: LZWS*, LZS*WS,
LVRC*WS, LMABF*WS
NOTICE: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. Filter
mustbeusedwithltermonitorfor3000
gallon rating
General Installation Instructions
1. Theselterkitsmust be installed in compliance with all
state and local laws and regulations governing the
installation and use of this product. Maximum inlet
water temperature 100°F (38°C).
2. Mountlterheadinasuitablelocation,usingthelter
mounting bracket and screws supplied. Allow enough
roomunderthelterheadforinstallationandremovalof
ltercartridge(13"minimum).
3. Connectthecoldwatersupplytothelterthrougha
shut-offvalveand3/8"O.D.tubing(suppliedbythe
installer). For ease of servicing, the shut-off valve
shouldbelocatedwithineasyreachofthelter.
NOTE:Theinletandoutletttingsuppliedas
partofthelterheadareJohnGuestSuperseal
ttingsthataccept3/8"O.D.tubingonthelter
inletand1/4"O.D.tubingontheoutlet.Theymay
be used with copper, semirigid nylon or
polypropylene tubing, with a rated working
pressure equal or greater than encountered in
application. Do not use soft or braided tubing.
4. CAUTION: If supply pressure will ever exceed
100 psi, install a pressure regulator to limit the
inletpressuretothelterto100psiorbelow.
DONOTATTACHHOTWATERLINETOFILTER.
Tomakeconnectionsonthelterhead,loosenlocknut.
Push the tube end past both o-rings to a positive stop in
thelterheadrecess-approx.1",locknutmayhaveto
be backed out a little more. Screw the locknut hand tight
to seal (See Fig. 1). Ends of tubing must be cut square
and free of burrs and sharp ends that could cut or nick
the o-rings.
5. Connect the outletoftheltertotheinletoftheunion
usingthe1/4"O.D.polytubingand1/4"unionsupplied.
6. Removelterfromcarton, remove protective cap, attach
ltertolterheadbyrmlyinsertingintoheadand
rotatinglterclockwise.
Filter Replacement
1. Turn inlet water valve off.
2. Open bubbler or activate the electric eye to relieve pressure
build-up in the system.
3Removeusedlterfromheadbyrotatingltercounterclockwise.
4.Removenewlter from carton, remove protective cap; cap may
beplacedonoldltertoreducethechanceofwaterspillingfrom
lterhousing.
5.Attachltertolterheadbyrmlyinsertingintoheadand
rotatinglterclockwise.
NOTE:Thelterheadcontainsanautomaticshut-offvalvethat
stops the ow of water, if the lter is removed inadvertently
without shutting off the incoming water.
WaterSentry Plus In Wall Bottle Filler
7b. Turn on water supply and activate the electric eye on In-Wall
Bottle Filler until approximately 1 gallon of water is dispensed.
Please note that the electric eye activation times out at 30
seconds and will need to be activate repeatedly until one gallon
hasbeenpassed.Thisushingprocedurepurgesairandne
carbonparticlesfromthelter.When1gallonofwaterhas
beenpurgedthroughthebottleller,carefullyinspectallwater
connections for leaks.
FILTER KIT
EWF3000WaterSentry
®
Plus Kit
(Lead, Chlorine, Taste & Odor, and Particulate Class I Reduction)
FOR COMMERCIAL USE ONLY
®
®
NOTE: This system and installation shall comply with applicable
state and local regulations.
(NOTE:CTOreplacementlterisonlycertiedtoNSF42claims;seeWSF6000RPerformance
Data Sheet for additional information.)
IMPORTANT NOTE - To avoid danger of an electric shock hazard, disconnect power to
yourunitbeforeinstallingorreplacingthelter.
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATIONOFQUICKCONNECTFITTINGS
SIMPLYPUSHIN
TUBETOATTACH
TUBEISSECURED
INPOSITION
PUSHINCOLLET
TORELEASETUBE
PUSHINGTUBEINBEFORE
PULLINGITOUTHELPSTO
RELEASETUBE
A B C
FIG. 2
FIG. 1
SeeNote4:Screwthelocknuthandtighttoseal
The WaterSentry
®
Plus lteristestedandcertiedbyNSFInternationaltoNSF/ANSI42and53
forthereductionofChlorine,TasteandOdor,ParticulateClassI,andLead.