Installation

PAGE 5
4400DBFR_FTN_A LK4400DBFR_FTN_A
1000003955 (Rev. A - 06/17)
F
H
G
E
D
C
B
A
INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S)
Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A & B) into the connector(s) (provided with fountain). Insert the 1/8”
O.D. tube(s) coming from the fountain(s) push button actuator(s) into the connector(s). Trim any excess
length.
Step 2 - Secure the 1/8” O.D. tube(s) (Labeled C & D) to the waste line assembly. This line is a vent line and should
be open to the air.
Step 3 - Insert the 1/4” O.D. tube(s) (Labeled E & F) into the 1/4” union(s) (provided with valve assembly). Insert the
1/4” O.D. water lines coming from the fountain(s) into union(s). Trim any excess length.
Step 4 - Insert the 1/4” O.D. tube (Labeled G) into the air gap assembly.
Step 5 - Secure the 1/4” O.D. tube (Labeled H) to the waste line assembly. This line is a vent line and should be
open to the air.
LABEL A
(ON/OFF CONTROL LINE
FOR BUBBLER ONE)
LABEL F (WATER LINE)
LABEL G (DRAIN LINE)
LABEL E (WATER LINE)
LABEL B
(ON/OFF CONTROL LINE
FOR BUBBLER TWO)
LABEL C (VENT LINE)
LABEL H (VENT LINE)
LABEL D (VENT LINE)
FOUNTAIN CONNECTIONS
FIG. 3
FOUNTAIN CONNECTIONS
PLUMBING CONDUIT
(BY INSTALLER)
TO VALVE