Installation Instructions

Risk of injury due to electricity.
Potential risk from parts that have become live due to a
malfunction.
The electrical connection including wiring is described in
the operating and installation instructions.
CAUTION
Risk of injury due to malfunctions due to incorrect installa-
tion.
Excessive winding of the drive system leads to possible
destruction of system parts.
For safe operation, end positions must be set / program-
med.
Training courses by the manufacturer for specialized
companies.
NOTE
Power supply failure, braking of machine components and
other defects.
For safe operation, the system must be properly installed
and the end positions must be set on commissioning.
Damage to the RolTop by humidity ingress.
On protection class IP44 systems, all cables or plugs
must be protected against ingress of humidity. This action
must be taken immediately after removing the RolTop
from its original packaging.
The drive system must be installed in a position safe from
rain.
Important
On delivery (factory settings), the RolTop is in commissio-
ning mode.
It is necessary to set the end positions
(refer to section 5.6).
5.1 Mechanical mounting
Important preliminary consideration:
The working space around the installed drive system is
often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to
the mechanical installation and carry out respective chan-
ges, if necessary.
NOTE
Damage to electrical lines by pressure or tensile loads.
All electrical lines must be laid safe from pressure or
tensile loads.
Observe the bending radius of the cables (at least 50
mm).
Lay connection cables in a loop downwards to prevent
water from running into the system.
Damage to the drive system by impact loads.
Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system!
Never drop the drive system!
Damage to or destruction of the drive system by drilling.
Never drill into the drive system!
Important
Attach the RolTop only to the provided mounting elements.
Firmly mounted control units must be visible attached.
The fabric must be mounted on the winding shaft.
• The pro le tube must have suf cient clearance to the
motor tube.
Make sure there is suf cient axial play (1 - 2 mm).
Installation in pro le tubes
Push the drive with suitable adapter
and driving collar into the profile tube.
Protect the motor cable in order to
avoid damage from the driven com-
ponent.
Secure the counterbearings to pre-
vent axial movement, e. g. screw or
rivet on shaft carrier.
Axially secure the drive in the bea-
ring!
Attach the fabric to the shaft!
5.2 Electrical connection
WARNING
Danger to life due to incorrect electrical connection.
Risk of electric shock.
Before initial commissioning, check the correct connec-
tion of the PE conductor.
NOTE
Damage to the RolTop due to incorrect electrical connec-
tion.
Before initial commissioning, check the correct connec-
tion of the PE conductor.
Damage to or destruction of the RolTop due to ingress of
humidity.
For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also
be compliant with protection class IP44.
Damage to or destruction of the RolTop for models with
120 V 1 AC due to incorrect control.
Switches that are preset to OFF (dead man) for drive
systems must be mounted in viewing range of the RolTop
but away from moving parts and at a height above 1.5 m.
Important
For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary.
Particularly at the RolTop type S and depending on the
used mounting or adapter plate, it is necessary to remove
this screwed plate before replacing cables.
Only connect when the system is disconnected from
the voltage. To do so, disconnect the drive cable.
1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable.
2 Disconnect the plug.
3 Insert the device plug until the locking mechanism enga-
ges.
Removing and inserting the device plug
Delivery con-
dition
Remove plug Insert plug
Fig. 4 Removing and inserting the device plug
B
A
C
1
2
3
© elero GmbH US+CA | 5
Mechanical mounting | Electrical connection