User Manual

44 electrolux.com.au 45
The freestanding type installation uses the appliance as
supplied, and can be fitted in between cabinets, with
cabinets on one side or without adjacent cabinets. There is
no clearance requirement to adjacent side cabinets.
To ensure cooker stability, the anti-tilt brackets must be
installed, and the end of chain attached to the appliance
must be placed onto the hook attached to the rear wall.
Installation of anti-tilt brackets and hook
Measurements
are to be adjusted
to account for
the thickness of
any skirting board
or tiles coming
between the back
of the appliance
and the wall
Hole location for
hook installation
840mm
376mm
425mm
194mm
Cabinet construction for freestanding installation
The anti-tilt brackets must be secured to the floor at
rear of cavity with an appropriate fastener according
to dimensions in diagram.
Gas only: The hook is to be secured to the back
wall in the location shown above with an appropriate
fastener capable of withstanding a 10kg load (not
supplied).
Connect services to the appliance prior to placing
into cavity.
To locate appliance, slide into cavity ensuring the rear
left and right foot of appliance are captured by the
anti-tilt brackets.
Gas only: Before the appliance is fully pushed into
position, place the chain attached to the rear of
appliance onto the wall hook.
895mm
600mm
600mm minimum vertical
clearance from combustible
surfaces
Gas Hob 910mm
(adjustable 910-930mm)
Induction Hob 906mm
(adjustable 906-926mm)
15mm height of trivet
from hob
Anti-tilt Bracket
Chain
900mm
minimum
Wall hook
755mm
900mm
600mm
INSTALLATION OF EFEP955 & EFEP915 (CONTINUED) INSTALLATION OF EFEP955 & EFEP915 (CONTINUED)
Cabinet construction for slot in installation
To convert the freestanding appliance to a slot in
installation the kick panel provided on the appliance
is removed and the appliance is mounted on a plinth.
This enables a continuous cupboard kickboard to be
installed, giving a more integrated appearance. There is
no clearance requirement between oven and adjacent
side cabinets.
Installation of anti-tilt brackets and stops
Location of holes
for front stops
414
183
475
The brackets are to be secured to the back wall with
appropriate fasteners.
The bottom edge of the brackets rest on the
horizontal support surface.
Two stops are to be screwed to the plinth in locations
as shown (stops provided). The stops locate into slots
in the base of the appliance to prevent the product
from being pulled forward when installed.
Measurements from the rear wall are to be adjusted if
there are tiles etc, that come between the appliance
and the wall.
Once services are connected, product can be lifted
onto the plinth and pushed back carefully, ensuring
the appliance engages into both brackets at the rear
and the front stops.
If the product requires removal for service, it must be
lifted at the front approximately 5mm to clear the front
stops prior to being pulled forward.
Anti-tilt
brackets
755mm
900mm
600mm
900mm
minimum
This surface to be level with the top edge
of the kick board
600mm minimum vertical
clearance from combustible
surfaces
600mm
Gas Hob 765mm
Induction Hob 761mm
895mm