Technical data

Services
Never allow the pump to run continuously
for more than 15 minutes.
Note: When refilling the water container, the
pump assembly may be left unplugged into
the wall socket so that the pump can be kept
off the ground by inserting the hose into the
groove on the underside of the plug. But, the
pump assembly MUST be unplugged
BEFORE replacing the pump into the refilled
water container.
WHALE ‘ELITE’ MICROSWITCH
TAPS
The micro switch taps are used when the
water supply is not pressurised.
When the tap is turned on the micro switch
(which is fitted inside the tap) activates the
pump to supply water.
Operation
Swivel the tap spout (a) to the desired
position over the sink, lift the control lever (b)
to activate the pump and allow water to flow
simultaneously. To adjust the temperature
swivel the lever (c) to the left or right as
shown opposite.
Cleaning
It is recommended that a non-abrasive damp
cloth is used for cleaning the Elite
Tap/Shower.
Microswitch Replacement: A microswitch
replacement kit is available (ref. MT8000).
Note: Before commencing microswitch
replacement ensure instructions are read
through thoroughly. The entire process can
be completed without the need to remove
the tap from the worktop.
Before you Start
1. Ensure pump is isolated.
2. Position lever in central, i.e. mixer, off
location.
Microswitch Replacement
1. Carefully remove lever cap. A recess at
the back of the lever cap is provided to
assist with this.
2. Remove screw with No. 2 Pozi
screwdriver. Note the position of the lever
at this stage.
3. Lift off the lever.
4. Note the position of actuator before re-
moval. Flange should be facing forward.
5. Remove actuator.
6. To remove shroud, squeeze clips with one
hand and slide shroud off with other hand.
7. Remove microswitch, using finger and
thumb, pull up and outwards.
24
Important
Note position of
ACTUATOR before
removing it.