Complete Owner's Guide

11
1. The gas service to the dryer must
conform with local codes and
ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1/
Pre-Installation Requirements
3-wire power supply cord
(not supplied)
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type
SRDT rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug
connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see “Electrical connection
(non-Canada) - 3-wire cord” in Electrical
Installation section.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
4-wire power supply cord
(not supplied)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type
SRDT or DRT (as required) rated at 240
volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends
or closed loop connectors and marked for
use with clothes dryers. For 4-wire cord
connection instructions see “Electrical
connection (non-Canada) - 4-wire cord” in
Electrical Installation section.
Electrical requirements for
gas dryer:
CIRCUIT - Individual, properly polarized
and grounded 15 amp. branch circuit
fused with 15 amp. time delay fuse or
circuit breaker.
POWER SUPPLY - 2-wire, with ground,
120 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped
with 120 volt 3-wire power cord.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).
Gas supply requirements
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.