Positioning
Place the freezer horizontally on a firm surface, resting
on all four wheels. Use a wooden block or similar object
to compensate for any bumps/holes in the floor's
surface.
The room should be dry and adequately ventilated.
If the room temperature exceeds 32°C, or falls below
freezing point, the freezer will not function as it should.
Do not place the freezer close to sources of heat,
radiators, chimneys, etc. and do not place the freezer in
direct sunlight.
If the freezer has been handled standing on end, it
should be allowed to stand in the normal position for
about 12 hours before switching it on.
Ensure that the appliance is installed where it is easily
accessible for the engineer in the event of a breakdown.
Technical Specifications
Installation
Model ECN 1547 ECN 2247 ECN 2747 ECN 3147 ECN 4147 ECN 5147
Volume (gross) litres
Volume (net) litres
Height without/with roller cm
Width cm
Depth cm
Weight kg
Energy consumpt./24h kWh
Freezing capacity kg/24h
Hold-over time hours
Rated power W
147
143
86,1/86,8
59,5
66,5
35
0,78
13
25
80
220
215
86,1/86,8
79,5
66,5
39
0,94
14
26
80
271
265
86,1/86,8
93,5
66,5
44
1,05
15,5
27
80
313
306
86,1/86,8
105
66,5
49
1,15
17
28
85
414
404
86,1/86,8
132,5
66,5
56
1,37
19
32
105