Drawing : - TPC447 Issue :-5 Date : - 13/10/17 CS90E INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 CS90E PACKAGE CONTENTS Item Description Quantity 10590GE-US Dehumidifier 1 3944110 PVC tube – 3/8” I/D 7.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 INTRODUCTION Designed for a wide range of applications, the CS90E dehumidifier is a rugged, industrial unit which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 Download the app from apps.ebacusa.com The CS90E dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. An active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 SPECIFICATIONS MODEL: CS90E HEIGHT: 15.2” (386mm) WIDTH: 14” (353mm) DEPTH: 22” (564mm) WEIGHT: 84lbs (38 kg) AIRFLOW: 230 CFM (390M3/hr) POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 33°F – 95°F REFRIGERANT: R-407c (15.2 oz) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit must have a clearance of 0.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 OPERATION The following procedures should be followed to test the CS90E for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. 2. Setting the humidistat Turn fully clockwise • 3.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Fan motor burnt out 2. Dirty refrigeration coils 3. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2. Damaged fan Water flooding inside the machine 1.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 CS90E SPARE PARTS LIST DESCRIPTION NUMBER PART NUMBER QUANTITY 1 Humidity Sensor 1619514 1 2 Defrost Timer 1619516 1 3 Filter 2013831 1 4 Condenser Coil 2059000 1 5 Evaporator Coil 2059001 1 6 Capillary Tube 3014249 2 x 30” 7 Drain Tubing 3014338 9 Feet 8 Solenoid Valve 3020837 1 9 Filter Dryer 3020901 1 10 Compressor 3022198 1 11 Solenoid Coil 3030451 1 12 Capacitor 3030908 1 13 Mains Lead 3035148 1 14
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 Page 14 of 16
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 Page 15 of 16
Drawing : - TPC447 Issue :-5 Date : - 13/10/17 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.