Drawing : - TPC222 Issue :-7 Date : - 09/12/13 BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 BD80 PACKAGE CONTENTS Item Description Quantity 10264SR-US Dehumidifier 1 TPC222 Manual 1 BD80XE PACKAGE CONTENTS Item Description Quantity 10264GR-US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 INTRODUCTION Designed for a wide range of applications, the BD80-XE is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 SPECIFICATIONS MODEL: Ebac BD80 / BD80-XE HEIGHT: 34” WIDTH: 17” DEPTH: 26” WEIGHT: BD80 – 97 lbs BD80XE - 101 lbs AIRFLOW: 360 CFM POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 33°F – 95°F REFRIGERANT: R-407c (13 oz) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 OPERATION The following procedures should be followed to test the BD80-XE for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. 2. Check dehumidification process as follows: CAUTION: DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION A. Place unit on a level surface. B. Start up unit by switching to “ON”.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, 4, AND 5. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 BD80-XE SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY Compressor 1 (RGA5467EXA) 3022169 1 N/A 1 Compressor Overheat 2 Protector 3 Compressor Capacitor 3030908 1 4 Condenser Coil 2026014 1 5 Evaporator Coil 2026013 1 6 Filter Dryer 3020901 1 7 Fan Motor Assembly 3035753 1 8 By-pass Valve 3020814 1 9 Mechanical Timer 3030781 1 10 Hour Meter 3030779 1 11 Rocker Switch 3035914 1 12 Terminal Block 303146
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labour required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 Page 11 of 16
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 Page 12 of 16
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 Page 13 of 16
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 Page 14 of 16
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 Page 15 of 16
Drawing : - TPC222 Issue :-7 Date : - 09/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.