USER MANUAL CRAWL SPACE DEHUMIDIFIER Model:OX-60PA Please keep this manual carefully for further reference Email:support@lienuis.com Website:www.lienuis.
CONTENT INSTRUCTIONS...................................................................................................................1 BEFORE YOU BEGIN........................................................................................................2 IMPORTANT SAFETY TIPS...........................................................................................4 PRODUCT OVERVIEW.....................................................................................................
INSTRUCTIONS Thank you for choosing the dehumidifier by Lienuis! We hope it will bring great convenience to your work and life. We recommend that you save the user manual properly for future reference. Before using this product, please read the user manual carefully to ensure that this product functions at its best.
BEFORE YOU BEGIN This restoration dehumidifier remove moisture of room . which commonly used in basement, warehouse, villa and many so on. The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect(GWP)and is available worldwide.Because of its efficient energy properties,R32 is highly suitableas a coolant for this application.Precautions must be taken into consideration due to the coolant's flammability.
■ This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. ■ This appliance is designed to use indoor ,not for outdoor.
IMPORTANT SAFETY TIPS Your safety is the most important thing we concerned! Please read this manual carefully and fully understand before operating your appliance. WARNING OPERATIONAL PRECAUTIONS WARNING-to reduce the risk of fire,electric shock or injury to persons or property: ■ If the supply cord is damaged,it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard. The appliance shall be disconnected from its power source during service.
■ Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. ■ The appliance shall be stored in a room witllout continuously operation sources (for cxample:open flames,an operating gas appliance or an operating electric heater). ■ The appliance shall be stored so as to prevent mechanical damage from occurring. ■ Do not piece or burn,even after use. ■ Be aware that refrigerants may not contain an odour.
3.General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall beavoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. 4.
8.Checks to the refrigeration equipment Where electrical components are being changed,they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed.If in doubt consult the manufacturer'stechnical department for assistance.
PRODUCT OVERVIEW Parts Diagram Handle Front View Duct adapter Remote control Air outlet Control panel signal cable interface External pump signal cable interface Acess door Water pipe Screws Control panel Power cord Drain connect Unit cover Unit cover Air inlet with removable filter Ceiling mount gasket Adjustable feet Back View 8
OPERATION INSTRUCTION Humidity Display Water Full Alert Auto Mode Continuously Drying Mode Sleep Mode Timer Display Temperature Display Timer Down On/Off Up Mode Switch Button Description A.On/Off(Power) Button Press the on/off button and the machine will start running (one beep). Press the button again to the turn the machine off. this button while on electric, screen light on, machine automatically goes to standby mode,display screen shows environmental humidity. B.
D.ADD Button Press this button to adjust the set humidity (20-90%) or timing time (0-24h) in an upward cycle.Press the button for 3 seconds to switch between Fahrenheit and Celsius temperatures.Increase the humidity by pressing this button at normal mode, humidity increase 1%RH with each press, buzzer rang each time with the press, press the button for 1 second can increase the humidity continuously; E.Minus Button Press this button to down cycle to set humidity (20-90%) or timing time (0-24h).
Humidity Control In auto mode or sleep mode, press the up and down adjustment button to cyclically adjust the set humidity. Each time the up (or down) button is pressed, the set humidity will increase (or decrease) by 1%. During the adjustment of the set humidity, the set humidity will flash and display, after the adjustment is completed, it will flash and display 5 times to confirm, and then switch to display the ambient humidity. Additional Function 1.
Ⅱ: Take out the duct adapter and adjustable rubber feet from the machine body 1. Unscrew the 2 screws under the lower cover, and remove the lower front panel. 2. Use a screwdriver to remove the 2 screws on the top cover and remove the top front panel. 3. Take out the duct adapter and adjustable rubber feet from the machine body. 4. After the accessories are taken out, install the top front panel and lower front panel.
Ⅲ: Ducting installation 1. Align the duct adapter with the 4 screw positioning holes on the side. 2. Lock and fix the duct adapter with screws. 3. The user can put the exhaust pipe (purchased by the user according to the demand) on the duct adapter, and it must be placed within the buckle position. 4.You can install the flex duct yourself,the duct adapter diameter is 6.88inch/17.5cm.
Ⅴ: Ceiling mount gasket installation When the machine is suspended in the air, the machine needs to be installed with ceiling mount gasket. Flat Spacers Spring Spacers Screws Ceiling Mount Gaskets 1. Install the ceiling mount gasket in the body (accessories: 4 ceiling mount gaskets, 12 spring spacers, 12 flat spacers, 12 screws) 2. 1 screw with 1 spring shim and 1 flat shim. 3.
Ⅵ: Wall assembly method for control panel When the machine is shipped, the control panel is assembled on the front of the machine. In order to facilitate the user to install the control panel on the wall, the control panel needs to be removed and the control panel installed on a wall surface that is convenient for operation, as follows. 1. Remove the 2 handel screws of the lower cover below the machine. 2.
6. Connect the signal wires to the terminals of the control panel inside the upper cover of the control panel assembly, install them in place, and then fix the upper cover on the lower cover. Screws 7. Then plug the other end of the signal cable of the control panel into the signal interface of the machine.
Drainage Method I: Water pipe drainage method Drain outlet/External water pump inlet Water Pipe Operation instructions: When using the water pipe drainage method, connect the water pipe at the drain, place the water pipe in place, place the other end of the water pipe at the drain, or at the drain sink, or in the water storage container; turn on the machine to use the water pipe drainage method. Dehumidifiers Adopt Drain by Gravity, the collected condensation water can be drained by gravity.
Ⅱ.External pump drainage method(not include pump,need to buy) Vertical drainage available Drain outlet/External water pump inlet Water pipe A Water pipe B External pump signal cable interface Water pump signal line Water pump power cord Water pump When it is necessary to connect an external water pump, oneend of the drainpipe is connected to the water outlet, and theother end is connected to the water inlet of the water pump.
Cleaning and Maintenance Note: Before cleaning and maintaining the machine, please make sure to turn off the machine and unplug it from the power source to prevent electric shock. Cleaning : Before doing any cleaning and maintenance work on the machine, the machine must be turned off, unplugged, and no water should be spilled on the machine. Use a soft, damp cloth to clean the casing.
2. Clean the filter Use a vacuum cleaner to gently absorb the dust on the surface of the filter. If the filter is very dirty, you can use tap water to rinse the filter, and completely cool and dry it, then put it back into the forward air sheet, which can improve the performance of the machine. Suggestion: Clean the filter once after every 3 months of use. 3.
Part List Dust adapter Adjustable feet 4 User manual 41 21
Troubleshooting Symptom Cause Solution Power outage Machine Won't Run Low Air Flow Water Leakage Loud Noise Restoration of power supply Power plug is not connected Connect the plug to the socket well The machine's protection device is Room temperature over 113 ℉ activated so that the machine does not or below 38℉ run Filter with dirt accumulation Cleaning filters The air inlet or outlet is blocked Remove obstructions Refrigerant leakage Contact agent or manufacturer for repair Remove the panel
Customer Service Lienuis offers a limited 1-year free warranty on these crawl space dehumidifiers,with original proof of purchase(typically you maybe only requested to offer the order number or other information to prove a genuine purchase,instead of an invoice) and where a defect has arisen, wholly or substantially, as a result of faulty manufacture,parts or workmanship during the warranty period.
CRAWL SPACE DEHUMIDIFIER Model:OX-60PA Email:support@lienuis.com Website:www.lienuis.