® 1/2 HP – 1 HP – 1½ HP INSTRUCTION MANUAL COMMERCIAL-GRADE WATER CHILLERS MICRO COMPUTER CONTROL Instruction manual - Safety precautions and warnings - Operation and maintenance of machine - Terms of warranty 1. Features 2. Safety precautions and warnings 3. Technical specifications 4. How to select the right machine 5. Performance curve 6. Installation 7. Operation 8. Maintenance 9. Circuit diagram 10.Troubleshooting 11.
Features Thanks for choosing this EcoPlus water chiller. This product is designed for both horticulture and marine water. - Panasonic or Toshiba compressor with excellent durability and low noise. Extremely energy efficient. - Finned condenser produced in the U.S. - Aluminum radiator made with the aluminum imported from Japan that is coated with anticorrosive paint.
Safety Precautions and Warnings Plug and socket can withstand 4-5 times of the rated current. ! ! Do not plug in the power before completing the installation. Do not remove outer casing when the machine is working. Do not touching working components. ! Caution To keep machine normal working, the below should be strictly followed: Do not install the unit at a place exposed to sunlight, rain, humidity or liquid splash. Installation should be preformed by experienced technician.
Technical Specifications 1/2 HP Water Chiller Volts Watts BTU’ s of Cooling Amps Weight Inlet Fitting Size Outlet Fitting Size Refrigerant Recommended Water Pump Recommended Tank Size (hydroponic application) Recommended Tank Size (aquarium application) 100 gal 1 HP Water Chiller Volts Watts BTU’s of Cooling Amps Weight Inlet Fitting Size Outlet Fitting Size Refrigerant Recommended Water Pump Recommended Tank Size (hydroponic application) 100-250 gal Recommended Tank Size (aquarium application) 120-60
Performance Curve 1/2 HP #728707 Temperature (ºF) 91.4 87.8 Ambient Temperature 84.2 80.6 77 73.4 69.8 66.2 Water Temperature 62.6 59 55.4 4 2 8 6 10 14 12 16 18 20 22 24 28 32 36 Test Condition Water Volume: 132gal Flow Rate: 555gal/H 4 1 HP #728708 Temperature ( ) 95 91.4 87.8 Ambient Temperature 84.2 80.6 77 73.4 Water Temperature 69.8 66.2 62.
Installation The installation of the chiller must comply with the safety precautions and warnings. The unit must be used with a circulating system and a filtering system. As outlined below: aquarium or reservoir -- filtering system or filter -- water pump -- inlet of chiller/warmer --outlet of chiller/warmer--aquarium/reservoir.
Installation The product has two terminals on one end, with the bottom one for inlet and the top for outlet. Connection of the aquarium/reservoir and water pump can be made with either soft or hard tubing (for high water flow, hard tubing is better). For the tubing diameter please refer to the diameter of the connector supplied. When using soft tubing, make sure there is no bending, entanglement or pressure applied to the tube, as this may block the water flow.
Operation (1)Temp setting: a. Press “SET” to enter setting feature, digital control switch, display pre-set temperature; b. Press c. Stop pressing any key for 6 seconds ,digital control panel will exit to temperature display, and the setting takes effect. The machine will start refrigerating automatically. (2) Calibrating of the temperature If the displayed water temp is different from the actual water temp, calibrating the digital display as below: a.
Maintenance Precautions Control panel and motor must be kept dry. If water or any liquid is found on the chiller, please turn off the power immediately and wipe it off with cloth before restarting. Do not tilt or lay the machine on its back. If the machine has been tilted or laid, please position it upright and wait 30 minutes before restart.
Circuit Diagram T1 P1 Transformer RL1 L RL4 O O 1 CN1 RL3 Comp. Relay LED3 Control Panel Main Control Board LED1 COOLING POWER LINES RL2 Fan Relay SW2 SW1 SW3 COMP J1 TP4 OFAN-H TP2 TP5 N M Compressor ~ N L UP 1 OUT/P SET DOWN Capacitor Capacitor G J2 1 IN/T SENSOR Power Supply Intelligent Touch Control Panel for Chiller 9 T1 Transformer P1 RL1 RL4 RL3 O O COOLING LED1 1 CN1 POWER LINES RL2 Comp.
Trouble Shooting Failures may be caused by improper operation or maintenance. Before sending the defective products for repair, check the lists below. Failure Possible cause Check Point Machine not working Broken circuit of fuse or air switch; Change fuse, check the power bad connection of power cord; switch, plug, connecting terminal; power supply problem check if voltage and frequency comply with the rated.
Warranty Card Product From which shop Shop Address Date of purchase / / Shop signature Purchaser signature The product is warranted to be free of defects in manufacturing and material for one (1) year from the date of purchase. Please retain your dated original receipt or invoice as proof of purchase, and return the defect to place of purchase. Please note that, this warranty does not cover damage from accident, misuse or abuse.
www.sunlightsupply.