Translation of the original operating instructions
3.2 Nominal data
Motor M6D110-GF
Phase 3~ 3~ 3~ 3~
Nominal voltage / VAC 400 400 400 400
Connection Δ Y Δ Y
Frequency / Hz 50 50 60 60
Type of data definition ml ml ml ml
Valid for approval /
standard
CE CE CE CE
Speed / min
-1
890 690 1010 700
Power input / W 600 400 730 430
Current draw / A 1.2 0.68 1.29 0.8
Max. back pressure / Pa 105 56 50 26
Min. ambient temperature
/ °C
-40 -40 -40 -40
Max. ambient
temperature
/ °C
65 65 60 60
Starting current / A 4 3.5
Maximum safe operating
speed / min
-1
1140
@ 70 °C
1140
@ 70 °C
1140
@ 70 °C
1140
@ 70 °C
Phase 3~ 3~
Nominal voltage / VAC 480 480
Connection Δ Y
Frequency / Hz 60 60
Type of data definition ml ml
Valid for approval /
standard
CE CE
Speed / min
-1
1070 820
Power input / W 810 550
Current draw / A 1.35 0.8
Max. back pressure / Pa 55 35
Min. ambient temperature
/ °C
-40 -40
Max. ambient
temperature
/ °C
55 55
Starting current / A
Maximum safe operating
speed / min
-1
1140
@ 70 °C
1140
@ 70 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 32.3 28.3 32.3
Efficiency grade N 40 36 40
Power input Pe / kW 0.61
Air flow qv / m³/h 7050
Pressure increase total psf / Pa 101
Speed n / min
-1
885
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 23.8 kg
Size 630 mm
Surface of rotor Coated in black
Material of terminal box PP plastic
Material of blades Press-fitted sheet steel blank, sprayed
with PP plastic
Material of wall ring Sheet steel, pre-galvanised and coated in
black plastic (RAL 9005)
Material of guard grille Steel, coated in black plastic (RAL9005)
Number of blades 5
Direction of air flow "V"
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F4-1
Mounting position Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode S1
Motor bearing Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box
Motor protection Thermal overload protector (TOP)
brought out
Cable exit Axial
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval EAC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
Item no. 10109-5-9970 · ENG · Revision 83190 · Release 2014-08-11 · Page 5 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com