User Manual
Operating instructions
W3G710-GS30-01
Translation of the original operating instructions
3.2 Nominal data
Motor M3G150-FF
Phase 3~
Nominal voltage / VAC 400
Nominal voltage
range / VAC
380 .. 480
Frequency / Hz 50/60
Type of data definition ml
Speed / min
-1
1030
Power input / W 1700
Current draw / A 2.7
Max. back pressure / Pa 180
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
70
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 38.4 31.1 35.1
Efficiency grade N 43.3 36 40
Power input Ped / kW 1.67
Air flow qv / m³/h 13600
Pressure increase total psf / Pa 159
Speed n / min
-1
1035
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 38.8 kg
Size 710 mm
Surface of rotor Coated in black
Material of electronics
housing
Die-cast aluminium, coated in black
Material of blades Aluminium sheet insert, sprayed with PP
plastic
Material of wall ring Sheet steel, pre-galvanised and coated in
black plastic (RAL 9005)
Material of guard grille Steel, coated in black plastic (RAL9005)
Number of blades 5
Blade angle 0°
Direction of air flow "V"
Direction of rotation Clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F4-1
Mounting position Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode S1
Motor bearing Ball bearing
Technical features - Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- Output for slave 0-10 V
- Input for sensor 0-10 V or 4-20 mA
- External 24 V input (programming)
- External release input
- Alarm relay
- Integrated PID controller
- Motor current limit
- PFC, passive
- RS485 MODBUS RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Over-temperature protected
electronics / motor
- Line undervoltage / phase failure
detection
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box
Motor protection Reverse polarity and locked-rotor
protection
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval C22.2 Nr.77 + CAN/CSA-E60730-1;
EAC; UL 1004-7 + 60730
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
Item no. 50433-5-9970 · ENG · Revision 82539 · Release 2014-05-08 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com