User Manual

Operating instructions
R2E210-AB34-05
Translation of the original operating instructions
Unacceptable
operating point
Check operating point
Overtemperature of
motor
Ambient temperature
too high
Lower ambient
temperature if possible
Insufficient cooling Improve cooling
If you have any other problems, contact ebm-papst.
5.1 Cleaning
NOTE
Damage to the device during cleaning.
Malfunction possible
Do not clean the device using a water jet or high-pressure
washer.
Do not use any cleaners containing acids,
bases or solvents.
Do not use any pointed or sharp-edged objects to clean.
5.2 Safety test
What has to
be tested?
How to test? Frequency Which
measure?
Check the
protective
casing against
accidental
contact for
damage and to
ensure that it is
intact
Visual inspection At least every
6 months
Repair or
replacement of
the device
Device for
damage
Visual inspection At least every
6 months
Replace device
Mounting the
connection lines
Visual inspection At least every
6 months
Fasten
Mounting of
protective
earth connection
Visual inspection At least every
6 months
Fasten
Check the
insulation of
the wires for
damage
Visual inspection At least every
6 months
Replace wires
Weld seams
for crack
formation
Visual inspection At least every
6 months
Replace device
Item no. 11881-5-9970 · Revision 82891 · Release 2014-06-06 · Page 9 / 9