Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 DD700 10550GR-US – 220V / 3PH / 60HZ INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 DD700 PACKAGE CONTENTS Item Description Quantity 10550GR-US Dehumidifier 1 TPC400 Manual 1
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 UNPACKING Carefully remove the DD700 dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 SPECIFICATIONS MODEL: DD700 HEIGHT: 1020mm (40”) WIDTH: 711mm (28”) DEPTH: 584mm (23”) WEIGHT: 80Kg (176.4lbs) POWER SUPPLY: 220V, 3 ph, 60Hz POWER 7.5 kW (max) F1 CONTROLS FUSE 2A 250V 5x20 Cartridge fuse PROCESS AIRFLOW MAXIMUM: 1500m3/hr (883 cfm) PROCESS AIRFLOW NOMINAL: 700m3/hr (412 cfm) REGENERATION AIRFLOW NOMINAL: 160m3/hr (94 cfm) PROCESS AIR OUTLET DIA: 200mm (8”) REGENERATION AIR OUTLET DIA: 150mm (6”) ROTOR WHEEL SPEED: 13.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 UNIT CAPACITY The ambient conditions of the area to be dehumidified will determine the amount of water extraction the unit is cable of. Measure the ambient conditions of the area to be determined and then use that information with the following capacity diagram to determine the unit capacity.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 INSTALLATION The DD700 is designed for indoor use. The unit should be placed on a level surface and a space of 3 ft free around all faces to allow access for any duct work and servicing. Connecting duct work: The regeneration outlet must be ducted to outside the area being dehumidified. The outlet duct spigot is 6” diameter and only 6” ducting or greater should be attached. The process outlet can be ducted to a specific area or another room.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 Control Settings Once the unit is positioned correctly, required duct work attached and the power supply connected, the fan speeds and temperature control need to be set correctly. The fan speed controls are located behind a removable cover, to the right of the main controls. The controls are numbered 1 to 10, with 10 being the maximum speed. The temperature control regulates the temperature of the reactivation airflow onto the desiccant wheel.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 FAN PERFORMANCE CURVES For example: If the total system resistance is 500pa then the process fan selector would have to be set to No 7 to achieve the required airflow of 412 cfm For example: If the total system resistance is 300pa then the regen fan selector would have to be set to No 8 to achieve the required airflow of 94 cfm
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 OPERATION The electrical controls are located on the front of the unit. They are: • On / Off Switch M Dehumidifier in continuous operation A Dehumidifier operation by means of an external humidistat 0 Dehumidifier OFF • An hour counter is provided to display the total time the unit has been in operation • DRYING lamp – unit is in drying mode. • HEATING lamp – indicates heating elements are on. Cycle on/off when in drying mode.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 SAFETY -WARNING♦ DO NOT ALLOW CHILDREN TO PLAY WITH OR AROUND THE UNIT. ENSURE THE UNIT IS INACCESIBLE TO CHILDREN WHEN NOT ATTENDED.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 ROUTINE MAINTENANCE & REPAIR WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE. SWITCH OFF THE DEHUMIDIFIER APPROXIMATELY 15 MINUTES PRIOR TO REMOVING ANY PANELS, ALLOWING THE HEATER TO COOL DOWN To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: • We recommend that the filters are checked at least once a month.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC INDUSTRIAL PRODUCTS LTD SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14
A B C 6 290 PROCESS AIR OUTLET 580 40 5 MAINS INLET GLAND ELECTRICAL CONNECTIONS PANEL POWER ISOLATOR HUMIDITY SENSOR WIRING GLAND n200 n150 40 17 REGENERATION AIR OUTLET 718 4 4 301 634 D 301.7 17 5 65 263 43 6 133 314 451 3 DO NOT SCALE IF IN DOUBT ASK 3RD ANGLE PROJECTION 19 9 7 3 851.7 12/02/13 1 2 ORIGINAL COMMENTS TITLE 2 MATERIAL DIMENSIONS IN m.m. TOLERANCES UNLESS OTHERWISE STATED 0. 1 FINISH 0.25 0.0 0.05 0.00 ANGULAR 0.5 DEGREE BISHOP AUCKLAND Co.
A 6 5 4 3 DO NOT SCALE IF IN DOUBT ASK 3RD ANGLE PROJECTION 19 9 7 TITLE 2 MATERIAL DIMENSIONS IN m.m. TOLERANCES UNLESS OTHERWISE STATED 0. 1 FINISH 0.25 0.0 0.05 0.00 ANGULAR 0.5 DEGREE BISHOP AUCKLAND Co. DURHAM ENGLAND ORIGINAL GENERAL ASSEMBLY / OVERVIEW 1 N/A N/A 1 1/10 SHEET 2 OF 3 W DAGLISH DD700 DRG.NO. CAD SCALE : DRAWN : A B 12/02/13 1 2 COMMENTS B DATE ISS.
5 4 12/02/13 1 DETAIL A SCALE 1/3 DATE ISS. 2 TITLE ORIGINAL COMMENTS GENERAL ASSEMBLY / OVERVIEW 1 D A 3 DO NOT SCALE IF IN DOUBT ASK 3RD ANGLE PROJECTION 2 MATERIAL DIMENSIONS IN m.m. TOLERANCES UNLESS OTHERWISE STATED 0. 1 FINISH 0.25 0.0 0.05 0.00 ANGULAR 0.5 DEGREE BISHOP AUCKLAND Co. DURHAM ENGLAND N/A N/A 1 1/8 SHEET 3 OF 3 W DAGLISH DD700 DRG.NO.
Drawing : - TPC 400 Issue :-5 Date : - 28/04/14 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.