Specification

SPECIFICATIONS
• 120V/AC, 60 Hz
• Incandescent/Tungsten/Halogen/LED/Electronic
Low Voltage (ELV) — 600W
• Magnetic Low Voltage — 600VA
• Fluorescent, Compact Fluorescent — 5.0A/600W
• Motor Load — 1/6 HP
NOTE - A Ground connection is required in the
wallbox where the sensor will be installed
DESCRIPTION
• This Sensor Wall Switch can replace a standard
wall switch in any of the following applications:
• Single location – one Single Pole switch
• Two location – one location is the sensor
and the other location is a standard 3-way
switch
• Two location – replace both 3-Way switches
with sensors
• The OS306U turns ON automatically when a
person enters the room
• The VS306U requires manual activation to turn
ON the lights
• Both OS306U and VS306U will automatically turn
OFF lights after a selectable time delay
• OS306U includes a light level adjustment for
daylight to prevent motion from turning ON the
lights
OPERATION INSTRUCTIONS
Auto ON Sensor – OS306U:
• OS306U will turn on lights automatically when a person enters the room
• Lights will turn OFF automatically when no motion is detected after a selectable time delay
• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 10 minutes, 20 minutes
and 30 minutes
Manual ON Sensor – VS306U:
• The VS306U must be turned on manually with the ON/OFF button
• Lights will turn OFF automatically when no motion is detected after a selectable time delay
• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 10 minutes, 20 minutes and 30 minutes
(factory default)
• When the lights have turned OFF due to a lack of motion, the lights will turn ON automatically if motion is
detected within 30 seconds
INSTALLATION INSTRUCTIONS
WARNING:
• Turn OFF circuit breaker or remove fuse(s) and verify that power is OFF before wiring
• Never wire any electrical device with power turned ON. Wiring the device with the power ON may
cause permanent damage to the device and void the warranty
• If you are unsure about any part of these instructions, or if the wiring does not match the descriptions
given, you should call a qualified electrician
CAUTION:
• Must be installed and used in accordance with all applicable electrical codes
• If a bare copper or green ground connection is not available in the wallbox, contact a qualified
electrician for installation. Do not install without proper ground connections
• Do not exceed maximum device ratings
• For use ONLY with permanently installed fixtures of these types: Incandescent/Tungsten/Halogen,
Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent, Compact Fluorescent, LED
• May also be used with motors up to 1/6 HP
• To avoid overheating and possible damage to other equipment, do not use to control receptacles
• Use only #14 or #12 copper wire with these devices
Installing OS306U & VS306U
Refer to the wiring diagrams and install the sensor according to these directions
For single pole applications, wire the sensor switch according to wiring diagram #1 using the wire nuts
provided.
OS306U Motion Sensor Switch (Auto ON/Auto OFF)
VS306U Motion Vacancy Sensor Switch (Manual ON/Auto OFF)
ENGLISH
www.eaton.com
www.eaton.com/wiringdevices
EIS-0153-E (REV.A)
1. The sensor black wire will connect to the hot wire in the wallbox.
2. The sensor red wire will connect to the wire which goes to the light fixture.
3. The sensor blue wire is not used and should be capped off with a wire nut.
4. The sensor green wire will connect to the ground wire in the wallbox.
5. Install the sensor loosely using the mounting screws provided.
6. Apply power and wait one minute. Verify that the sensor works by pushing the
ON/OFF button to verify the lights turn ON and OFF. You must wait 2 seconds between
button presses. If the lights do not work, then turn OFF the power and swap the
connections on the sensor black and red wires.
7. Apply power again and verify that the sensor works by pushing the ON/OFF button to verify
the lights turn ON and OFF.
8. Turn power OFF and go to COMPLETING THE INSTALLATION.
EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY
Eaton Wiring Devices (Eaton) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS 2 YEAR
LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF 2 YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY
TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY.
To obtain warranty service for any properly installed Eaton device that proves defective in normal use send the defective device prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203
Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton will not
be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in
shipment to Eaton.
EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE DEVICE, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL
DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE DEVICE OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT.
ENGLISH
Hot/Phase/Fase
Hot/Phase/Fase
Black/Noir/Negro
Ground/
Terre/Tierra
Bare/Nu/Desnudo
Neutral/
Neutre/Neutro
White/
Blanc/Blanco
Green/Vert/
Verde
Neutral/Neutre/Neutro
White/Blanc/Blanco
OS306U or VS306U sensor/OS306U ou VS306U/
Sensor OS306U ó VS306U
Light Fixture
Luminaire
Lámpara
3-Way
3-Voies
3-Vias
Blue/Bleu/Azul
Red/Rouge/Rojo Black/Noir/Negro
Output
Sortie
Salida
1. Remove the existing switch in the 3-way location where the first sensor will be installed.
a. The sensor black wire will connect to the two black wires in the wallbox.
b. The sensor red wire will connect to the red wire in the wallbox.
c. The sensor blue wire is not used and should be capped off with a wire nut.
d. The sensor green wire will connect to the ground wire in the wallbox.
e. Install the sensor loosely using the mounting screws provided.
2. Remove the existing switch in the other 3-way location where the second sensor will be installed.
a. The sensor black wire will connect to the black wire coming from the first wallbox.
b. The sensor red wire will connect to the red wire coming from the first wallbox and to the black wire
going to the light fixture.
c. The sensor blue wire is not used and should be capped off with a wire nut.
d. The sensor green wire will connect to the ground wire in the wallbox.
e. Install the sensor loosely using the mounting screws provided.
3. Apply power and wait one minute. Verify that the sensors work by pressing the ON/OFF buttons on each
sensor. If the light does not turn ON and OFF from either or both sensors, you must swap the red and black
sensor wire on that sensor.
4. Re-install the sensor loosely, apply power again, an verify the sensor works by pushing the ON/OFF button
to verify the lights turn ON and OFF. You must wait 2 seconds between button presses.
5. NOTE - The light will turn OFF when both sensors time out or when the user manually turns OFF both
sensors.
6. Turn power OFF and go to COMPLETING THE INSTALLATION.
COMPLETING THE INSTALLATION:
1. Secure sensor into the wall box using two mounting screws provided. Turn the circuit breaker ON.
2. Allow the sensor to stabilize for one minute. The sensor is now ready to detect motion.
3. Verify that Power is ON by pushing the ON/OFF button. Lights should turn ON.
4. NOTE - The sensor time delay is factory preset (OS306U = 5 minutes; VS306U = 30 minutes).
5. If you want to change the time delay proceed as follows:
a. Remove the button from the sensor by pressing in the hook on the button, and then lift up on the button
as shown in Fig. 4.
b. Set the time delay using the dial on the right side by using a small Phillips screwdriver. Align the arrow
on the dial to desired time delay.
c. To allow the installer to quickly confirm that the sensor is functioning properly the time delay can
be set to TEST. This will set a time delay of 5 seconds, which allows quick feedback that the sensor is
working properly.
6. Replace push button by sliding it upward into the slots in the front housing and push down until the button
hook snaps into place.
7. Push the ON/OFF button to verify that the lights turn ON/OFF, and that the buttonoperates freely.
8. Install the wallplate.
OS306U Motion Sensor Switch (Auto ON/Auto OFF)
VS306U Motion Vacancy Sensor Switch (Manual ON/Auto OFF)
Red/Rouge/Rojo
Output/Sortie/
Salida
3 traveler wires are required/3 fils de navette sont nécessaires/
Se requieren 3 alambres de conexión
Neutral/Neutre/Neutro
Neutral/Neutre/Neutro
White Traveler/Navette Blanc/Alambre
de conexión blanco
3-Way Switch/Interrupeur 3-Voies/Interruptor 3-Vias
Neutral
Neutre
Neutro
White
Blanc
Blanco
OS306U or VS306U sensor/OS306U ou VS306U/
Sensor OS306U ó VS306U
White
Blanc
Blanco
Black
Noir
Negro
Light Fixture
Luminaire
Lámpara
Black/Noir/Negro
Hot/Phase/Fase
First Location/Premier Emplacement/
Primera Ubicación
Black Traveler/
Navette Noir/
Alambre de
conexión negro
Second Location/Second Emplacement/
Segunda Ubicación
Red Traveler/Navette Rouge/
Alambre de conexion rojo
3-Way
3-Voies
3-Vias
Blue/Bleu/Azul
Ground/
Terre/Tierra
Bare/Nu/
Desnudo
Green/
Vert/
Verde
Black/Noir/Negro
Hot/
Phase/
Fase
Ground Bare/
Terre Nu/
Tierra
Desnudo
Common/
Commune/
Común
3 traveler wires are required/3 fils de navette sont nécessaires/
Se requieren 3 alambres de conexión
Hot/Phase/Fase
Hot/Phase/
Fase
Black/Noir/Negro Black/Noir/Negro
First Location/Premier Emplacement/Primera Ubicación
Second Location/Second Emplacement/Segunda Ubicación
Black Traveler/Navette Noir/
Alambre de conexión negro
Black
Noir
Negro
OS306U or VS306U sensor/OS306U ou VS306U/
Sensor OS306U ó VS306U
White Neutral/Navette Blanc/Blanco Neutro
White
Blanc
Blanco
3-Way
3-Voies
3-Vias
Blue/Bleu/Azul
Red Traveler/Navette
Rouge/Alambre de
conexion rojo
Ground/Terre/Tierra
Bare/Nu/Desnudo
Green/Vert/
Verde
Neutral/Neutre/Neutro
White/Blanc/Blanco
3-Way Switch/Interrupeur 3-Voies/
Interruptor 3-Vias
Output/
Sortie/Salida
Red/Rouge/Rojo
Ground Bare/Terre Nu/
Tierra Desnudo
Light Fixture
Luminaire
Lámpara
Common/Commune/
Común
Hot/Phase/Fase
Hot/Phase/
Fase
Black/Noir/Negro
First Location/Premier Emplacement/
Primera Ubicación
Second Location/Second Emplacement/Segunda Ubicación
OS306U or VS306U sensor/DéctecteurOS306U ou VS306U/
Sensor OS306U ó VS306U
Neutral/Navette/Neutro
3-Way
3-Voies
3-Vias
Blue/Bleu/Azul
Ground/Terre/Tierra
Bare/Nu/
Desnudo
Green/Vert/
Verde
Neutral/Neutre/Neutro
White/Blanc/Blanco
Output/
Sortie/Salida
Red/Rouge/Rojo
Red Traveler/Navette Rouge/
Alambre de conexion rojo
White/Blanc/Blanco
White/Blanc/Blanco
Neutral/Navette/Neutro
OS306U or VS306U sensor/DéctecteurOS306U ou VS306U/
Sensor OS306U ó VS306U
2 traveler wires are required/2 fils de navette sont nécessaires/
Se requieren 2 alambres de conexión
3-Way
3-Voies
3-Vias
Blue/Bleu/Azul
Ground/Terre/Tierra
Bare/Nu/
Desnudo
Green/Vert/
Verde
Hot/
Phase/
Fase
Output/
Sortie/Salida
Black/
Noir/
Negro
Red/Rouge/
Rojo
Black/
Noir/
Negro
Light Fixture
Luminaire
Lámpara
2. Lift up button/
Elever le bouton/
Levante boton
1. Press to release hook
/
Appuyez pour libérer
le crochet/
Presione para soltar
el gancho
SYMPTOM POSSIBLE CAUSE SOLUTION
Light does not
automatically turn ON
For OS306U only
1. Circuit breaker is turned OFF or fuse
is blown
2. Bulb is defective
3. Poor ground connection
4. Control may be wired incorrectly
5. Daylight sensing prevents lights ON
1. Turn circuit breaker ON, or replace fuse
2. Replace light bulb
3. Verify all wiring ground connections
including to ground wire align
4. Check wiring
5. Re-adjust daylight sensing level
Light does not
automatically turn OFF
1. Motion is still present
2. Time Delay has not expired
3. Control may be wired incorrectly
4. Switch is being triggered by air vent
or other heat source
1. Make sure there is no motion during the
time delay period
2. No action needed or shorten TIME DELAY
3. Check wiring, ground wire should be
connected
4. Move switch to the other switch location
(if a 3-Way), or determine the source
triggering the switch, and alter the air flow
Light does not stay ON 1. Motion is not detected
2. TIME control is set for too short
a delay
1. Create movement in front of the sensor
for 5 seconds
2. Set switch TIME control to longer
time period
Remote switch does
not work
1. Control may be wired incorrectly 1. Check wiring
0
15’
MAJOR MOTION
450 SQ. FT.
25’
0
COVERAGE PATTERN
8’
12’
8’
12’
DIAGRAM 1: SENSOR IN ONE LOCATION / SCHÉMA 1: DÉTECTEUR EN UN EMPLACEMENT / DIAGRAMA 1:
SENSOR EN UNA (1) UBICACIÓN
DIAGRAM 2A: SWITCH IN LOCATION WITH HOT WIRE / SCHÉMA 2A: INTERRUPTEUR
SUR L’EMPLACEMENT AVEC FIL DE PHASE / DIAGRAMA 2: INTERRUPTOR EN
UBICACIÓN CON ALAMBRE DE ENERGÍA
DIAGRAM 2B: SENSOR IN LOCATION WITH HOTWIRE / SCHÉMA 2B: DÉTECTEUR SUR
L’EMPLACEMENT AVEC FIL DE PHASE / DIAGRAMA 2B: SENSOR EN UBICACIÓN CON
ALAMBRE DE FASE
DIAGRAM 3: SENSORS IN BOTH LOCATIONS / SCHÉMA 3: DÉTECTEUR SUR LES DEUX
EMPLACEMENTS / DIAGRAMA 3: SENSORES EN AMBAS UBICACIÓNES
DIAGRAM 4 / SCHÉMA 4 / DIAGRAMA 4:
1. Remove the existing switch in the location where the sensor will be installed.
a. The sensor black wire will connect to either one of the black wires in the wallbox.
b. The sensor red wire will connect to the other black wire in the wall box.
c. The sensor blue wire will connect to the red traveler wire in the wallbox
d. The sensor green wire will connect to the ground wire in the wallbox.
e. Install the sensor loosely using the mounting screws provided.
2. Remove the existing switch in the other 3-way location.
a. Connect the two black wires together.
b. Connect the bare ground wire in the wallbox to the common terminal
(usually a black screw or a marking such as COM or COMMON near the terminal) on
the 3-way switch.
c. Connect the red wire to either of the other switch terminals.
d. Re-install the 3-way switch and tighten securely.
3. Apply power and wait one minute. Verify that the sensor works by pushing the
ON/OFF button. You must wait 2 seconds between button presses. The lights
should turn ON and OFF. If the lights do not work, then turn the power OFF and
swap the connections to the sensor black and red wires.
4. Apply power again and verify the sensor works by pushing the ON/OFF button to verify
the lights turn ON and OFF.
5. Turn power OFF and go to COMPLETING THE INSTALLATION.
For 3-way applications, wire the sensor switch according to wiring diagram #2A or
2B using the wire nuts provided. The sensor may be placed at either end of the 3-way
circuit.
For 2 sensor applications, wire the sensor switches according to wiring diagram #3
using the wire nuts provided.
1. Remove the ON/OFF pushbutton to access
the light level adjustment (See Figure 4)
2. Turn the LIGHT LEVEL dial to the full
clockwise position.
3. Turn the TIME DELAY dial to the TEST position and hold the screwdriver on the dial.
Do not move for 5 seconds until the light turns OFF. Immediately turn the dial back to
the full counterclockwise position. The light should stay OFF.
4. Stand to the side of the sensor to allow the device to sense the normal light level in
the room.
5. Move your hand continually back and forth
about 2 feet in front of the sensor while slowly
turning the LIGHT LEVEL dial counterclockwise
until the light turns ON.
6. Adjust the Time delay to the desired setting.
7. The Light Level adjustment is now complete.
Replace the ON/OFF pushbutton.
TROUBLESHOOTING:
If you have a problem with your Motion Sensor, first follow this guide. If the problem
persists, call the customer service hotline at 1-866-853-4293 between 8:00 A.M. and 6:00 P.M.
EST weekdays.
5
1
0
3
0
P
R
U
E
B
A
TIME DELAY/DÉLAI DE
TEMPORISATION/
RETRASO DE TIEMPO
TURN TO SET/TOURNER POUR MODIFIER LE RÉGLAGE/
GIRE PARA AJUSTAR
T
E
S
T
/
T
E
S
T
/
LIGHT LEVEL/INTENSITÉ
LUMINEUSE/NIVEL DE LUZ
DIAGRAM 5 / SCHÉMA 5 / DIAGRAMA 5:
Daylight Sensing Adjustment (OS306U only):
• The Daylight sensing feature prevents
lights from turning ON when the room is
adequately illuminated by natural light
• NOTE - The factory setting for this
adjustment is fully counterclockwise,
which permits motion detection to turn the
lights ON regardless of the ambient light
level in the room
• This adjustment requires a small Phillips
screwdriver and must be made when the
light level in the room is at the desired
level for the lights to turn ON

Summary of content (1 pages)