CHI Control Components Enclosures UPS catalogue • Bullet 1 • Bullet 2 • Bullet 3 Eaton UPS solutions Headline be nt to Conte ided prov • Bullet 4 • Bullet 5 • Bullet 6
Energizing a world that demands more. Discover today’s Eaton. Powering business worldwide As a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably.
We provide integrated solutions that help make energy, in all its forms, We deliver: • more practical and Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power • With 2012 sales of $21.
Eaton’s heritage in industry -leading UPS design and production For more than 50 years, Eaton has been safeguarding the critical systems of businesses across the globe. Whether protecting a single desktop or a large data centre, Eaton solutions provide clean, uninterrupted power to keep mission-critical applications working.
Contents UPS basics Why use UPS? 6 Power protection for different needs 7 PC, Workstation and home AV UPS Eaton Protection Box 8 Eaton Protection Station 10 Eaton 3S UPS 12 Eaton Ellipse ECO UPS 14 Eaton 5S UPS 16 Eaton Ellipse PRO UPS 18 Network and Server Eaton 5SC UPS 20 Eaton 5P UPS 22 Eaton 5130 UPS 24 Eaton 5PX UPS 26 Eaton 9130 UPS 28 Eaton EX UPS 30 Eaton 9SX UPS 32 Eaton 9PX UPS 34 Data Center and Facility UPS Eaton BladeUPS 36 Eaton 9155 and 9355 UPS 38 Eaton
UPS basics Why use UPS? An uninterruptable power supply (UPS) protects IT equipment and other electrical loads from problems that can affect the public electricity supply. It performs the following three basic functions: 1. Prevents hardware damage typically caused by surges and spikes. Many UPS models continually condition incoming power as well. 2. Prevents data loss and corruption.
UPS topologies for different needs Three common UPS topologies described below provide varying degrees of protection for your equipment. Passive standby topology (off-line) is the most frequently used UPS topology for protecting PCs against power failure, power sag and power surge. In normal mode, the UPS supplies power to the application directly from the mains, filtered but without active conversion. The battery is charged from the mains.
PC, Workstation and home AV UPS Surge protection Eaton Protection Box 1/5/8 sockets Surge protection The Eaton Protection Box multi-way block with high performance surge protection is a simple solution for protecting delicate equipment. Effective surge protection The Protection Box is designed to filter the power supply for delicate equipment to protect it against surges, interference and the indirect effects of lightning.
Eaton Protection Box Power ON indicator Widely spaced sockets for transformer units, Active protection indicator 1 PLC-ready outlet Telephone / broadband protection (for Protection Box 5 and 8) Replaceable surge protection module All outlets with safety shutters Eaton Protection Box 8 Eaton Protection Box 5 Audio/Video protection module available (for Protection Box 5 Tel@ + TV and 8 Tel@ + TV only) TECHNICAL SPECIFICATIONS Rating (A/W)* Voltage/frequency IEC 61643-1 tested PowerLine compatibi
PC, Workstation and home AV UPS Surge protection & UPS Eaton Protection Station 500/650/800 VA Combined UPS/surge protection/ multiple socket device Innovative solutions offering total protection for home computers and digital leisure devices.
Eaton Protection Station Surge protection status indicator One PLC-ready outlet Line protection for telephone/ ADSL Internet Replaceable batteries Spaced outlets, compatible with local standards Reset button (circuit breaker) Outlets with surge protection USB port (650 & 800) and Windows/Linux/Mac software Outlets with surge protection and back-up power Indicator for mains/battery operation with additional audible alarms for overload and faults Two EcoControl outlets (650 & 800) Eaton Pro
PC, Workstation and home AV UPS Single phase UPS Eaton 3S UPS 550/700 VA Power protection for office and home computer equipment Protection against power problems • The Eaton 3S UPS helps to protect your computer equipment in case of everyday events such as lightning strikes, storms, overdemand on the utility grid, accidents, and natural disasters knocking out power without warning. • In the event of a total blackout, the unit provides sufficient battery backup time to last through most power outages.
Eaton 3S UPS 3 Schuko or FR outlets with surge 4 IEC outlets with surge protection protection 3 Schuko or FR outlets with battery 4 IEC outlets with battery backup and surge protection backup and surge protection On / Off button + LED interface On / Off button + LED interface USB port USB port Dataline protection Dataline protection Replaceable battery Replaceable battery 7 Reset button (circuit breaker) 8 Wall-mounting system Eaton 3S 700 DIN Eaton 3S 700 IEC TECHNICAL SPECIFICATIONS
PC, Workstation and home AV UPS Single phase UPS Eaton Ellipse ECO UPS 500/650/800/1200/1600 VA Energy-efficient power protection for business computers Eaton Ellipse ECO range • With an efficient electrical design and the EcoControl function (USB models), which automatically disables peripherals when the master device is turned off, the Eaton Ellipse ECO helps you make energy savings of up to 25 per cent compared to previousgeneration UPSs.
Eaton Ellipse ECO Three outlets with surge protection and backup , Four outlets with surge protection and backup one socket with surge protection only Four outlets with surge protection One EcoControl outlet (USB models) two EcoControl outlets (1200 & 1600) Tel/Internet and Ethernet protection Tel/Internet and Ethernet protection USB port (USB models) USB port Replaceable batteries Replaceable batteries Reset button (circuit breaker) Reset button (circuit breaker) Eaton Ellipse ECO 1200/160
PC, Workstation and home AV UPS Single phase UPS Eaton 5S UPS 550/700/1000/1500VA Affordable power protection for workstations Performance • The Eaton 5S UPS provides effective power protection, even in disturbed electrical environments. Voltage fluctuations are automatically corrected using an AVR device (booster/fader), without needing the batteries.
Eaton 5S UPS 3 1 LED user interface 4 2 Battery replacement panel 4 Data line protection 5 4 IEC 10A and 4 surge 1 5 3 USB port only IEC 10A 6 Circuit breaker reset button 2 6 Eaton 5S 1000i UPS TECHNICAL SPECIFICATIONS 550 700 1000 1500 Rating (VA/W) Electrical Characteristics Technology Input voltage range Output voltage Frequency 550 VA / 330 W 700 VA / 420 W 1000 VA / 600 W 1500 VA / 900 W Line-Interactive (AVR with Booster + Fader) 175V-275V 230 V 50-60 Hz autoselect
PC, Workstation and home AV UPS Single phase UPS Eaton Ellipse PRO UPS 650/850/1200/1600 VA Energy-saving power protection for workstations and small servers Ellipse Pro range • The LCD screen on the Eaton Ellipse PRO UPS provides clear information on its status and measurements. It also allows easy configuration of UPS settings. • The EcoControl function, which automatically disables peripherals when the master device is turned off, can cut energy consumption by as much as 20%.
Eaton Ellipse PRO UPS 1 3 sockets with surge protection and backup, one socket with surge protection only 1 4 sockets with surge protection and backup 2 4 sockets with surge protection 2 1 EcoControl socket 3 2 EcoControl sockets (1200/1600 models) 3 Telephone, internet and Ethernet protection 4 USB port 4 Telephone, internet and Ethernet protection 5 Replaceable batteries 5 USB port 6 Circuit breaker reset buttons 6 Replaceable batteries 7 Circuit breaker reset button Eaton
Network and Server Single phase UPS Eaton 5SC UPS 500/750/1000/1500VA Affordable and reliable protection for small business servers Easily manageable UPS • The new LCD interface provides clear status of the UPS key parameters such as input and output voltage, load and battery level, and estimated runtime. Configuration capabilities are also offered for output voltage, audible alarm and sensitivity. • The 5SC offers USB and serial connectivity.
Eaton 5SC UPS 3 1 LCD Interface : 2 Panel for batteries replace- Clear information on ment UPS status and measurements 1 3 1 USB port + 1 serial port 4 8 IEC 10A sockets 2 4 Eaton 5SC 1500i TECHNICAL SPECIFICATIONS Rating (VA/W) Format Electrical Characteristics Technology Line-Interactive High Frequency (Sinewave, Booster + Fader) Input voltage and frequency ranges without using batteries 184V–276V, 45–55Hz (50Hz system), 55–65Hz (60Hz system) Output voltage and frequency 230V (+6/–10 %) (
Network and Server Single phase UPS Eaton 5P UPS 650/850/1150/1550VA Eaton 5P is an energy efficient line-interactive UPS with advanced LCD and energy metering features. Manageability Available in tower and rack 1U format • The new graphical LCD display provides clear information on the UPS’s status and measurements on a single screen (in seven languages). Enhanced configuration capabilities are also available with easy-to-use navigation keys.
Eaton 5P UPS 4 5 1 Graphical LCD: - Clear information on UPS 3 One USB port + one serial port + remote ON/OFF and 1 remote power OFF connec- status and measurements - Energy metering - Enhanced configuration tor 4 8 IEC 10A sockets 2 (including two groups of capabilities - 3 Available in seven languages controlled sockets) 5 Communication card slot 2 Panel for batteries replacement (Hot swappable) Eaton 5P 1550i UPS TECHNICAL SPECIFICATIONS 650 850 1150 1550 Rating (VA/W) Technology
Network and Server Single phase UPS Eaton 5130 UPS 1250/1750/2500/3000 VA Line-interactive UPS Highest power performance • The 5130 protects connected equipment from five of the most common power anomalies: failures, surges, sags, under-voltage and overvoltage. • 0.9 power factor: more real power to your protected load. By delivering more real output power, the 5130 powers more servers than another UPS of equivalent VA rating with a lower power factor. 5130 is compatible with all modern IT equipment.
Eaton 5130 UPS 1 Access panel for battery replacement 5 1 2 Load segments 3 USB and serial ports and 4 Communication card slot 5 LED user interface 6 EBM connector 2 3 RPO/ROO connector 4 6 TECHNICAL SPECIFICATIONS Battery General LEDs Topology Diagnostics Transfer time ROO/RPO Rail kit/tower stand 13 status-indicating LEDs Line interactive Full system self-test at power up 1-4 ms typical Rear deck emergency stop connector (for remote on/off and power off) Included with all units Electr
Network and Server Single phase UPS Eaton 5PX UPS 1500/2200/3000 VA Exceptional efficiency, manageability and energy metering capabilities for IT managers Manageability Rack/Tower versatile • The new graphical LCD provides clear information on the UPS’s status and measurements on a single screen (one of seven languages). Enhanced configuration capabilities are also available with easy-to-use navigation keys.
Eaton 5PX UPS 1 USB port + 1 serial port + remote Graphical LCD display : - Clear information on UPS status ON/OFF and remote power OFF and measurements inputs - Enhanced configuration capabilities External battery (EBM) connector - Available in 7 languages 8 IEC 10A + 1IEC 16A sockets with energy metering (including 4 Access panel for battery replacement (Hot swappable) programmable sockets) Eaton 5PX 3000i RT2U Communication card slot TECHNICAL SPECIFICATIONS 1500 2200 3000 Rating
Network and Server Single phase UPS Eaton 9130 UPS 700/100/1500/2000/3000/5000/6000 VA Double conversion UPS Highest power performance • Double conversion topology. The 9130 constantly monitors power conditions and regulates voltage and frequency. Even when presented with the most severe power problems, UPS’s output remains within 3% of nominal voltage. • More real power. High 0.9 output power factor enables the 9130 to provide its full power capability to modern IT equipment.
Eaton 9130 UPS 1 Multilingual graphical LCD display 1 7 3 5 4 2 Panel for replacing batteries 3 One USB port + one serial port 4 One Relay Output + 6 5 EBM battery unit connector 6 Load segments 7 Communication card slot Technical specifications General LEDs Topology Diagnostics UPS bypass Rail kit Electrical Input Nominal voltage Voltage range Frequency range Electrical Output Power factor Voltage Frequency regulation Load crest factor 1 one EPO connector 2 User interface 2 Commu
Network and Server Single phase UPS Eaton EX UPS 700/1000/1500/2200/3000 VA Double conversion (online) Maximum availability Eaton EX 1500 • Topology: double conversion on-line UPS with automatic by-pass and power factor correction • Powershare: the Eaton EX output sockets are individually controlled to provide load-shedding to maximise the backup time and provide remote reboot and sequential start-up as standard • Continuous power supply: Hot swappable batteries.
Eaton EX UPS 1 USB port + 1 serial port + remote ON/OFF and emergency stop inputs LCD Multilingual display - 6 languages, EXB battery unit connector - displays measurements, EXB units recognised automatically - displays alarms, 8 IEC 10A sockets, including 4 Powershare pro - access to control and set-up menus grammable sockets and 1 IEC 16A socket Panel for batteries replacement Communication card slot (Hot swappable) Mountings for HotSwap MBP and FlexPDU Eaton EX 3000 TECHNICAL SPEC
Network and Server Single phase UPS Eaton 9SX UPS 5/6/8/11 kVA High performance Online double conversion UPS Performance and efficiency • Double conversion topology. The Eaton 9SX constantly monitors power conditions and regulates voltage and frequency. • With up to 95% efficiency in online double conversion mode the 9SX provides the highest efficiency level in its class to reduce energy & cooling costs. • With a 0.9 power factor the 9SX delivers 28% more power than UPS in its class.
Eaton 9SX UPS 1 Remote Off/On and Remote 4 DB Power Off connectors 5 2 Slot 9 with output contacts USB and serial ports 6 Input/Ouput for Network-MS, connections ModBus-MS or Relay-MS cards 3 External battery module Eaton 9SX 11kVA (EBM) connector with automatic detection (RJ-11) Technical Specifications 5kVA 6kVA 8kVA 11kVA Rating (kVA/kW) 5kVA/4.5kW 6kVA/5.4kW 8kVA/7.
Network and Server One phase UPS Eaton 9PX UPS 5/6/8/11 kVA Energy efficient power protection Performance and Efficiency Rack/Tower versatile 1:1 • Double conversion topology. The Eaton 9PX constantly monitors power conditions and regulates voltage and frequency. • With up to 95% efficiency in online double conversion mode and 98% in high-efficiency mode the 9PX provides the highest efficiency level in its class to reduce energy & cooling costs. • With a 0.
Eaton 9PX UPS 1 Remote Off/On and Remote Power Off connectors 5 8 IEC 10A sockets (2 groups of 4 manageable sockets) with cable retention system 2 Slot for Network-MS, ModBus-MS or Relay-MS cards 6 2 IEC 16A sockets with cable retention system 3 Parallel operation port (DB15) 7 DB 9 with output contacts 4 External battery module (EBM) connector with automatic detection (RJ11) 8 USB and serial ports 9 Input/Ouput connection Technical Specifications 5kVA 1:1 6kVA 1:1 6kVA 3:1 8kV
Data Center and Facility UPS Three phase UPS Eaton BladeUPS 12/24/36/48/60 kW Designed for data centres – to ensure maximum uptime and efficiency Simply scalable • Eaton BladeUPS provides scalable double-conversion backup power • BladeUPS is designed for the data centre -to work in harmony with your servers and IT equipment to ensure maximum uptime and maximum efficiency • Scalable architecture enables you to design, scale and grow your data centre as your demand grows.
Eaton BladeUPS TECHNICAL SPECIFICATIONS General Power Rating Efficiency Heat Dissipation Cooling 12 kW per UPS module Up to 98,6 per cent 371W/1266 BTU/hr at 100% rated load Fan cooled, temperature microprocessor monitored; front air entry, rear exhaust Audible Noise, Normal Operation <60 dBA at 1 meter Altitude Before Derating 1000 meters (3300 ft ASL) Input Input Voltage Voltage Range Frequency Range 400 Vac 400V: 311 to 519 Vac, phase to phase 50 or 60 Hz, ±5 Hz Input Current Distortion <5% wit
Data Center and Facility UPS One and Three phase UPS Eaton 9155 and 9355 UPS 8/11/12/15 kVA Double-conversion UPS Premium power performance • Double-conversion topology provides the highest level of protection available by isolating the output power from all input anomalies. • With a transformer-free design and sophisticated sensing and control circuitry the 9155/9355 delivers an efficiency of up to 92%.
Eaton 9155/9355 UPS 8-15 kVA Technical specifications UPS output power rating (0,9 p.f.) kVA 8 10 12 15 kW 7,2 9 10,8 13,5 General Efficiency in double conversion mode (full load) Efficiency in double conversion mode (half load) Efficiency in high efficiency mode Distributed parallelling with Hot Sync technology Field upgradeable <3% (100% linear load); <5% (reference non linear load) 0,9 (e.g.
Data Center and Facility UPS Three phase UPS Eaton 9355 UPS 20/30/40 kVA Double-conversion UPS Premium power performance • Double-conversion topology provides the highest level of protection available by isolating the output power from all input anomalies. • With a transformer-free design and sophisticated sensing and control circuitry the 9355 delivers an efficiency of up to 93%.
Eaton 9355 UPS Technical specifications Output power factor 0,9 (e.g. 27 kW at 30 kVA) kVA 20 30 40 Permitted load power factor kW 18 27 36 Overload on inverter 0,7 lagging - 0,8 leading 10 min 100-110%; 1 min 110-125%; 5 sec 125-150%; 300 ms >150% 60 min 100-110%, 10 min 110-125%; 1 min >125150% UPS output power rating (0,9 p.f.
Data Center and Facility UPS Three phase UPS Eaton 93E UPS 80/100/120/160/200 kVA Double conversion UPS Simply effective power protection • Double conversion provides the highest level of protection available by isolating the output power from all input anomalies. • With a transformer-free design and sophisticated sensing and control circuitry the 93E UPS delivers an efficiency of up to 98,5%.
Eaton 93E UPS General Output 80 100 120 160 200 kVA 72 90 108 144 180 kW Output wiring 3 ph + neutral Efficiency in double conversion mode (full load) Efficiency in double conversion mode (half load) 93.5% Nominal voltage rating (configurable) 220/380, 230/400 (default), 240/415 V 50/60 Hz Output UTHD <2% (100% linear load) Output power factor 0.9 Efficiency in High-Efficiency mode (HE) 98.
Data Center and Facility UPS Three phase UPS Eaton 93PM UPS 30/40/50/80/100/120/150/160/200 kW Maximum energy efficiency. Minimum operating costs. Lowest total cost of ownership • The 93PM UPS sets new standards, with an operating level of up to 97% in double conversion mode resulting in significant savings in operational costs. • > 99% superior efficiency is delivered in Energy Saver System mode (ESS). • Maximal power and energy density ensures a compact footprint.
Eaton 93PM UPS Technical specifications General Output wiring 3ph + N + PE 220/380, 230/400, 240/415 V 50/60 Hz UPS output power rating (1.0 p.f.) 30, 40, 50, 80, 100, 120, 150, 160, 200 kW Nominal voltage rating (configurable) Efficiency in double conversion mode Up to 97% Output UTHD Efficiency in Energy Saver System (ESS) > 99% < 1% (100% linear load). < 5% (reference non-linear load) Field upgradeable Yes Rated output power factor 1.
Data Center and Facility UPS Three phase UPS Power Xpert 9395 UPS 225/275/450/550/675/827/900/1100 kVA Double conversion UPS Premium power performance ™ • Double conversion provides the highest level of protection available by isolating the output power from all input anomalies. • With a transformer-free design and sophisticated sensing and control circuitry the 9395 UPS delivers an efficiency of up to 94,5%.
Power Xpert 9395 UPS Technical specifications UPS output power rating (0,9 p.f.
Racks, Enclosures and Airflow Management Eaton RP Series IT Rack 42U/48U Main Features • Unobstructed front, rear, bottom and top cable access, maximizes cabling flexibility for demanding network infrastructure • Four 482mm (19 inch) EIA-310-E vertical mounting rails with U-markings • Tool-less adjustable rail positioning reduces set up and refresh time • 3 point rail mounting gives superior top to bottom rigidity • Fast, easily removable doors, left or right hinge • Split rear doors reduce space requireme
Eaton RP Series IT Rack 42U 600x1200 42U 800x1000 42U 800x1200 48U 600x1000 48U 600x1200 48U 800x1000 48U 800x1200 Equipment Mounting Height Height Height (with caster wheels) Width (with side panels) Width (without side panels) Depth (with doors) Depth (without doors) Product weight Weight Capacity (static) Weight Capacity Maximum Rail Mounting Depth Door swing Rail Mounting Width 42U 42U 2043 mm 2043 mm 2062 mm 2062 mm 638 mm 638 mm 600 mm 600 mm 1057 mm 1257 mm 1000 mm 1200 mm 149kg 164kg 1364 k
Power Distribution PDUs Eaton FlexPDU Eaton HotSwap MBP FlexPDU range Power distribution The no hassle solution for improving availability and adding flexibility for single phase UPSs.
Eaton FlexPDU Eaton HotSwap MBP Flexible system for 19” rack-mounting or on Eaton RT UPSs French/Schuko/British/IEC 10A sockets IEC 16A output for cascading IEC 16A input socket Retaining clip Rotary bypass switch Colour coded input and output sockets for connecting the UPS NB: hard-wired version available TECHNICAL SPECIFICATIONS Maximum power Nominal Voltage Installation Format Installation Dimensions H x W x D Connection Inputs FR DIN BS Outputs IEC Eaton HotSwap MBP Eaton FlexPDU Eaton HotSwap
Power Distribution ePDUs Managed ePDUs Advanced Monitored ePDUs Switched ePDUs Managed ePDUs offer data centre managers maximum functionality and flexibility by providing a complete understanding of, and control over, data centre power distribution. Advanced Monitored ePDUs give data centre managers the detailed, accurate information and understanding needed to run a data centre efficiently and effectively. Switched ePDUs give control to the data centre managers.
Monitored ePDUs In-Line Monitored ePDUs Basic ePDUs Monitored ePDUs accurately monitor the current draw of the ePDU and branch circuit, to allow for provisioning and load balancing of servers, and to ensure current draw is not approaching breaker limits. In-line Monitored ePDUs are designed for new data centres, or for retrofitting to upgrade an existing infrastructure which lacks power monitoring.
Power management software & connectivity Intelligent Power Software Intelligent Power® Software is a suite of productivity tools for power management from Eaton. It greatly simplifies the supervision of power conditions and devices in today’s enterprise environment, scaling effortlessly from local area networks with a few UPSs and ePDUs to the most critical virtualised data centres. Administrators will value the many automatic functions of Intelligent Power Software.
Intelligent Power Manager Intelligent Power Manager is a productivity tool for administrators of several power devices and shutdown applications. It delivers the big picture and highlights key factors by concentrating information from multiple sources and displaying it in a single view. It also centralises alarm propagation making sure that important events are brought to those who need to know. IPM simplifies many routine maintenance tasks, including its own updates.
Power management software & connectivity Intelligent Power Protector When the power goes out for longer than your available battery runtime Intelligent Power Protector software facilitates automatic, graceful shutdown of computers, servers and network devices powered by a UPS, saving all work-in-progress and ensuring data integrity (IPP). IPP has also monitoring and alarm handling capabilities making it a complete solution for a single UPS.
Connectivity Options Web/SNMP cards are complete UPS monitoring, control and shutdown solutions in a networked IT environment. In case of alert the Web/SNMP card can notify users and administrators through e-mail and SNMP traps. In case of a prolonged power failure the protected computer systems can be shut down in a graceful manner with Intelligent Power Protector software. The unique three-port switching hub on the X-Slot model provides additional network connections.
Green life cycle Green by design Eaton is constantly working with customers to develop solutions that drive sustainable growth around the globe. Our UPS solutions strive for unparalleled energy efficiency, efficient resource use, maximimum use of recyclable materials and the reduction of emissions throughout the entire life of the product, from cradle to grave. 58 EATON UPS Catalogue Our engineers are constantly developing smarter ways to deliver ecological and economic benefits.
Design Manufacturing Taking account of the environment is a part of the design process at Eaton. Four characteristics guide the design team during their work: energy efficiency, resource efficiency, recycling and compliance with regulations. The Life Cycle Assessment (LCA) process is used to gather information about the potential environmental impact of a product. LCA@Eaton.
Technology Hot Sync Technology Paralleling UPS technology The number one function of a UPS is to supply continuous conditioned, reliable electricity to a critical load. In case of a single unit, reliability can be increased by modular design, where redundant internal modules can take over each others’ tasks, if one of the modules fails. To further increase reliability, a true parallel configuration can be employed, where two or more units share the load.
Hot Sync Technology The internal output impedance of a UPS is inherently mainly inductive, i.e. it looks as a small inductor in series with a stiff alternating voltage source. So, if there is any difference between the output voltage phases, it means that there is a power flow from unit to unit, resulting in unequal load sharing. In the Figure 3, two units have equal output voltages with phase angle displacement.
Technology ABM Technology Superior battery management Battery service life is a major contributor to UPS reliability. Since batteries are electrochemical devices, their performance gradually decreases over time. Premature wear-out means higher costs in terms of replacement labour and shorter service cycle. A worn battery entails a risk of unexpected load loss.
ABM Technology ABM cycle and operation – how does it work? The basic idea of ABM is to leave a fully charged battery in rest mode for most of the time, and then apply charge current only at certain intervals. Initially, in order to charge up a fully or partly discharged battery, the charger starts at a constant current appropriate for the battery type used.
Technology Energy Saver System ESS Energy Advantage Architecture (EAA) The rising demand for highly available, reliable and efficient power is a continuous challenge for data centre operators. Higher energy efficiency helps to address increasing environmental, regulatory and economic pressures. Eaton has developed innovative and proprietary technologies that improve system efficiency without compromising on reliability under the Energy Advantage Architecture (EAA) umbrella.
Energy Saver System No compromise on reliability In ESS mode the UPS safely provides mains current directly to the load when the input is within the acceptable limits by its voltage and frequency. If input power exceeds the predefined limits by frequency or voltage, the UPS switches to double conversion. If input power is outside the tolerances of the system, the UPS draws power from available battery modules.
Technology Variable Module Management System VMMS Energy Advantage Architecture (EAA) The rising demand for highly available, reliable and efficient power is a continuous challenge for data centre operators. Higher energy efficiency helps to address increasing environmental, regulatory and economic pressures. Eaton has developed innovative and proprietary technologies that improve system efficiency without compromising on reliability under the Energy Advantage Architecture (EAA) umbrella.
Variable Module Management System (VMMS) Maximised energy efficiency VMMS optimally employs uninterruptible power modules (UPMs) in the UPS to achieve higher efficiencies in double conversion mode in order to maximise the percentage load level of the remaining active UPMs by switching UPMs that are not needed to ready state*. This is calculated according to the UPMs’ VMMS load threshold – 80% by default – and the system configuration (redundancy requirements). This results in maximised energy savings.
Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customised, integrated solutions to solve our customers’ most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products.