All about safety for solar energy Using free energy – safe for its consumers. The Sun provides 15,000 times more energy than consumed worldwide – reliably and free of charge. Modern photovoltaic installations harness this energy by using solar cells on the roof, which convert the sunlight efficiently and sustainably into electric power. The generation of renewable electricity offers great potential for the future, but means a special challenge, too.
Eaton’s solutions Actively shape the future with safe photovoltaic systems and Eaton. Photovoltaic power plants convert sunlight directly into electrical energy. For this purpose, photovoltaic modules are used. A differentiation is made between grid-independent systems and systems coupled to the power grid. Photovoltaic systems that are coupled to the power grid feed the generated power directly into the electrical grid. There is no need for sophisticated intermediate storage.
The energy of the sun, converted by Eaton PV inverter Grid-connected inverter range from 1500 W up to 4600 W Eaton offers a complete range of monophase inverters from 1500 W up to 4600 W, to serve the individual requirements of each PV-system. This range is suitable for mono- and polycrystalline PV-arrays up to 40m². The maintenance-free inverters are highly reliable and easy to install. The embedded LCD display makes them easy to operate and service.
The energy of the sun – the quality of Eaton. The total power of a photovoltaic system does not only depend on the area of installed PV-modules but also on the adjustment and slope of the modules. Also components such as the inverter greatly affect the efficiency. By using Eaton’s inverters, maximum power is ensured. 5 W7400-7622.indd 5 04.07.
Safe disconnection and protection of PV arrays DC disconnection DC switch disconnectors Compact disconnectors for inverters customized enclosures or inverters. They are installed on 35 mm top-hat rails; their terminals facilitate the connection of all conventional conductor types. Eaton offers both enclosed and open switch-disconnectors. P-SOL open switchdisconnectors are intended for 6 W7400-7622.
Hazard-free fire-fighting U< PV fireman’s switch A house is on fire. A fire-fighting appliance approaches. The fire fighters climb out, see a solar installation – and can do very little. The fire services can frequently do little else than rescue persons and animals and prevent neighbouring buildings from catching fire. The reason being that PV installations generate voltages up to 1000 V, which are still generated even after the power inverter is switched off.
DC string protection String protection makes sense if the PV system has 3 or more strings and can be made with a DC fuse disconnector or a DC string circuit breaker. In addition to fuses, protection of photovoltaic strings is provided by string circuit-breakers. String protection devices protect photovoltaic modules from fault currents. They prevent reverse currents from intact modules to modules with a short circuit.
Safety and comfort for the building AC switchgear for buildings Miniature circuit-breakers (MCBs) and residual current devices (RCDs)) Digital residual current circuit-breakers (RCCB) Residual current breakers with overcurrent (RCBO) Miniature circuit-breakers (MCB) Distribution boards Digital technology makes it possible to achieve a new level in tripping accuracy, which helps to avoid unwanted tripping.
Surge protective devices Threats to electrical systems due to lightning and overvoltages are made safe by Eaton’s surge protective devices. The comprehensive product range offers protection up to the user. Easily fitted auxiliary switches facilitate monitoring of the functionality of the surge protective device. You can find further information regarding Eaton switchgear for disconnecting, protecting and switching of photovoltaic systems for commercial and industrial applications at www.eaton.
Wireless monitoring of the PV system & energy management for the building Wireless visualization of the generated energy Energy sensor up to 16 A and Energy-Manager Comprehensive information from the xComfort Energy Sensor and Energy Manager: The Room Manager with integrated Energy-Manager Software enables the user to monitor the power generation of their photovoltaic system. By connecting the Eaton energy sensor to the inverter, the current feed to the grid can be read out.
The safety of Eaton Safe disconnection: In case of fi re or flooding, the current grid will be shut down by the regional electricity supplier or the fire brigade. Eaton provides you with extra safety: Remote controlled switch disconnectors ensure the disconnection of the voltage producing modules from the grid.
Content Inverter Selection Information Technical Data Page 14 Page 26 DC Disconnectors Selection Information Technical Data Page 15 Page 28 DC String Protectionr Selection Information Technical Data Page 17 Page 31 Surge Protection Selection Information Technical Data Page 20 Page 35 Energy Management Selection Information Technical Data Page 23 Page 41 EATON CORPORATION Power inverters/DC and AC switchgear series W7400-7622.indd 13 13 04.07.
± Photovoltaic - Inverter ~ PV inverter grid connected ISG • • • • • • • • Transormerless design Equipped with MC3 plugs High efficiency Fanless LCD display GFCI integrated (RCMU) Works with monitoring software ENS meets VDE 0126-1-1 AC output MC3 Type designation Article No.
3:29 Uhr Photovoltaic - DC Disconnection DC DC switch-disconnector DC switch-disconnector P-SOL 2-poles • Rated operational voltage 1000 VDC • Utilization category DC-21A Rated op. current Ie Type designation Article No.
Photovoltaic - PV Off Switch, PV fireman's switch PV Off Switch • • • • Degree of protection IP 65 Tamper-proof to ISO 13850/EN 418 Reset by pulling or turning Red enclosure upper section Description Type designation Article No.
Photovoltaic - DC String Protection DC DC string circuit-breaker DC string circuit-breaker PKZ-SOL 2-poles • Rated operational voltage 900 VDC • Rated current In 4, 6, 12, 20 and 30 A • For permissible string short-circuit currents Isc of 1.6 up to 22 A Ie Isc Type designation Article No. Units per package 4A 7A 12A 20A 30A 1.6-3A 2.
Photovoltaic - DC String Protection C DC Fuse-disconnector (empty) FCFDC10DI-..-SOL • String protection of PV generator • The visual tripping indicator indicates the tripped fuse-link 50-400 V flashing 400-1000 V permanent light • Rated operational voltage 1000 VDC • For cylindrical fuse-links photovoltaic application • Lead-sealable Number of poles / Size Type designation Article No.
3:37 Uhr Photovoltaic - DC String Protection Cylindrical fuse-links Size / Rated current / Rated voltage Type designation C Article No. Units per package Fuse-Links ASFLC10-..
Photovoltaic - Surge Protection DC SPD-type T2 (Class C) Max. Cont. Op. Volt. UC Type designation Article No.
3:39 Uhr Photovoltaic - Surge Protection DC SPD-type T2 (Class C) PV surge protective device SOL-SP as a pre-wired unit with protection class II, degree of protection IP65 • For unearthed photovoltaic systems up to 600 VDC and 1000 VDC • Rated operational current Ie=30 ADC for versions MC3, MC4 Rated operational current Ie=32 ADC for version with metric cable glands • PE conductor has to be connected direct to the surge protection device PE terminal – metric cable gland M16 in the enclosure for PE conduc
Photovoltaic - Surge Protection AC SPD-type T2 (Class C) Max. Cont. Op. Volt. UC In (8/20)μs sg13309 Type designation Article No. Units per package 131755 131756 131757 131758 131759 131760 131761 131762 131773 131774 12 / 120 1 / 60 1 / 40 1 / 30 12 / 120 1 / 60 1 / 40 1 / 30 1 / 60 1 / 30 SPMT2PA-280 SPMT2PA-335 SPMT2PA-NPE 131778 131779 131783 4 / 120 4 / 120 4 / 120 Description Type designation Article No.
3:40 Uhr Photovoltaic- RF System - Flush-mounted devices Design rf05410 Type designation Article No. Units per package Energy sensor • The "energy sensor" is used to record the solar energy converted in the PV inverter and to forward this information to the Room-Manager equipped with "Energy management function". This type of device is used for capacities of 3-3680 W. It is used to determine current (A), voltage (V), power (kW) and energy (kWh).
Photovoltaic- RF System - Surface mounted devices Design Type designation Article No. Units per package Room-Manager: white, 1 VA, 230 AC, without Bluetooth rf09410 • The "Room-Manager" is a central display and operating device. In connection with the energy sensors (with or without external sensors), the solar energy emitted by the PV inverter is displayed.
3:41 Uhr Photovoltaic- Energy Management Design RF01506 Type designation Article No. Units per package USB-RS232 adapter cable • The "USB-RS232 adapter cable" is used to connect the PV inverter (with RS232 interface) to the laptop/notebook/PC (with USB port). In this manner, all data from the PV inverter can be evaluated by the "Watch-SOL Software". CRSZ-00/03 Design RF03107 Type designation 104932 Article No.
± Photovoltaic - Inverter ~ PV inverter grid connected indoors ISG1I • Field of application: For use with mono- and polycrystalline PV modules to build up a photovoltaic system • Transformerless design • High efficiency • Fanless design keeps the device clean • ENS acc. to VDE 0126-1-1 integrated • RCMU acc. to VDE 0126-1-1 integrated • Application acc. to IEC 60364-7-712 and IEC 62548*) Connection diagram ISG1I..../1 Technical Data ISG1I-1500/1 Electrical DC Max. DC power ± Max.
3:41 Uhr ± Photovoltaic - Inverter ~ PV inverter grid connected outdoors ISG.O • Field of application: For use with mono- and polycrystalline PV modules to build up a photovoltaic system • Transformerless design • High efficiency • Fanless design keeps the device clean • ENS acc. to VDE 0126-1-1 integrated • RCMU acc. to VDE 0126-1-1 integrated • Application acc. to IEC 60364-7-712 and IEC 62548*) Connection diagrams ISG1O..../1 ISG3O....
Photovoltaic - DC Disconnection DC DC Switch-disconnector P-SOL • Field of application: DC disconnection in photovoltaic systems between PV array and inverter to switch off the energy • No polarity • Any mounting position • Spring work contacts • Tested according to IEC/EN 60947-3, UL508 • Certificate TÜV-Rheinland Connection diagram Unearthed system Earthed system Technical Data P-SOL20 P-SOL30 P-SOL60 2 1000 VDC 20 A 500 A 700 A DC-21 A III 8 kV 1500 6 mΩ 2 1000 VDC 30 A 500 A 700 A DC-21 A III 8
3:42 Uhr Photovoltaic - DC Disconnection DC DC Switch-disconnector SOL30-Safety • Field of application: : DC disconnection in photovoltaic systems between PV array and inverter to switch off the energy • Remote release by undervoltage release 230V, 50Hz • Feedback of the switching status by auxiliary contacts 1 NO and 1 NC • Pre-wired unit ready for connection • Lock-able in OFF-position with a padlock • Any mounting position • Spring work contacts • Application acc.
Photovoltaic - DC Disconnection DC DC Switch-disconnector SOL as pre-wired unit • Field of application: DC disconnection in photovoltaic systems between PV array and inverter to switch off the energy • Pre-wired unit ready for connection • Lock-able in OFF-position with a padlock • Any mounting position • Spring work contacts • Tested according to IEC/EN 60947-3, UL508 • Certificate TÜV-Rheinland Connection diagram Unearthed system Earthed system Technical Data SOL20 SOL30 2 1000 VDC 20 A 500 A 700 A
3:49 Uhr Photovoltaic - DC String Protection DC DC string circuit-breaker PKZ-SOL • Field of application: DC circuit-breaker for string protection in photovoltaic systems • No polarity • Spring work contacts • Tested according to IEC/EN 60947-2 • Certificate TÜV-Rheinland Connection diagram Unearthed system Earthed system Technical Data PKZ-SOL4 PKZ-SOL7 PKZ-SOL12 PKZ-SOL20 PKZ-SOL30 Electrical Number of poles Rated operational voltage Ue Rated current In Thermal tripping characteristic Electromagnetc
Photovoltaic - DC String Protection DC DC string circuit-breaker PKZ-SOL Characteristic curve setting value - short-circuit-current According to the design for IEC 62548-1, the tripping current for the circuit-breaker must fall within a range of 1.4 to 2 times the value of the short-circuit current of the PV modules, in order to protect the PV modules.
3:53 Uhr Photovoltaic - DC String Protection DC C Fuse-disconnector FCFDC10DI-..-SOL • Design according to IEC 60947-1 Ed. 4.0, EN 60947-1:1999+A1:2000+A2:2001 IEC 60947-3 Ed. 2.
Photovoltaic - DC String Protection Cylindrical fuse-links C Fuse-Links ASFLC10-..A-gPV-SOL photovoltaic application • According to IEC 60269-1 and IEC 60269-4 • For fuse-switch-disconnectors FCFDC10DI Connection diagram Technical Data Electrical ASFLC10-..A-gPV-SOL 10x38 6 - 20 A / 1000 V DC 25 A / 900 V DC – 30 kA 2 ms Rated voltage Un Rated frequency Rated short-circuit breaking capacity τ = L/R Max.
3:57 Uhr Photovoltaic - Surge Protection DC SPD-type T2 (Class C), plug-in surge arresters SPPT2PA-...-2PE • Field of application: Connection For the protection of photovoltaic systems against transient overvoltage SPPT2PA-...-2PE caused by indirect lightning strike and switching operations. • Test class II according to IEC 61643-1 • SPD-type T2 according to EN 61643-11 • Types SPPT2PA-...
Photovoltaic - Surge Protection DC SPD-type T2 (Class C), plug-in surge arresters SPPT2PA-...-2+1PE • Field of application: Connection For the protection of photovoltaic systems against transient overvoltage SPPT2PA-...-2+1PE caused by indirect lightning strike and switching operations. • Test class II according to IEC 61643-1 • SPD-type T2 according to EN 61643-11 • Galvanic isolation in unearthed systems by means of a spark gap • Types SPPT2PA-...
3:58 Uhr Photovoltaic - Surge Protection DC SPD-Type T2 (Class C), PV surge protection device SOL-SP as a pre-wired unit Connection diagram INPUT u OUTPUT M16 • Field of application: For the protection of photovoltaic systems against transient overvoltage caused by indirect lightning strike and switching operations.
Photovoltaic - Surge Protection AC SPD-Type T2 (Class C), plug-in surge arresters SPMT2PA • Field of application: For the protection of photovoltaic systems against transient overvoltage caused by indirect lightning strike and switching operations. • Test class II according to IEC 61643-1 • SPD-type T2 according to EN 61643-11 • Types SPPT2PA-...
3:59 Uhr Photovoltaic - Surge Protection AC SPD-type 2 (Class C), surge arresters SPMT2PA-1+NPE, SPMT2PA-3+NPE • Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning strike and switching operations.
Photovoltaic - Surge Protection AC Auxiliary Switch for surge arresters ASAUXSC-SPM • Field of application: For mounting onto surge protective devices for external defect message transmission • Design basically in accordance with IEC 60947-5-1 • Can be mounted subsequently • Suitable for SPMT2PA Connection diagram Technical Data Electrical Rated insulation voltage Rated frequency Switching contact Minimum voltage per contact Rated operational current AC12 Maximum back-up fuse Overvoltage category Pollut
4:01 Uhr Photovoltaic - Energy Management Connection example for energy sensor CEMU-01/04 PV modules Note: The reading on the PV inverter might be different than the reading on the RoomManager. Reason: Leakage and drop of voltage at the wiring and/or the transmitting intervals from the energy sensor to the Room-Manager and the update intervals at the PV-inverter display.
Photovoltaic - RF system - Flush-Mounted Devices Energy sensor CEMU-01/04 45.5 26 Technical specifications Power supply Connections Power consumption Pre-protection Max. current Min. output Max. output Accuracy Measurement units 230VAC, 50Hz Lead wires solid, 2.5mm² 0.42VA LS 16A, characteristic C 16 A >3 W ≤3680 W 10% Energy in Wh, current in A, voltage in V, active power in W Frequency 868.
4:03 Uhr Photovoltaic - RF system - Surface-Mounted Devices Room-Manager CRMA-00/03 to CRMA-00/06 (without Bluetooth) CRMA-00/02 Technical Specifications Power supply Power consumption Pre-protection Frequency Type of transmission Indoor range 230VAC / 50Hz 1VA (without Bluetooth) LS 16A, characteristic C 868.
Eaton Corporation Eaton is a leading power management company. Eaton operates worldwide with products, systems and services in the electrical, hydraulic, aerospace, truck and automotive sectors. Eatons Electrical Sector Eatons Electrical Sector is the worldwide leader in products, systems and services for energy distribution, safe electricity supply and automation in industrial, residential and purpose-built buildings, public facilities, energy providers, commerce and OEMs.