User's Manual
Table Of Contents
- Radio Overview
- Controls & Display
- General Operation
- 3.1 Basic Operation
- 3.1.1 Turning Power ON and Setting Volume
- 3.1.2 Persistent Settings
- 3.1.3 Power-Up Password
- 3.1.4 Speaking into the Microphone
- 3.1.5 Display Backlight Control
- 3.1.6 Display Viewing Angle & Contrast Adjust (Standard Control Head Only)
- 3.1.7 Zone / Channel Display and Select
- 3.1.8 Setting Squelch Control
- 3.1.9 Zone Edit
- 3.1.10 Transmit Disable
- 3.1.11 Operation At Extended Range
- 3.1.12 Preventing Vehicle Battery Discharge
- 3.1.13 Cleaning the Control Head
- 3.1.14 Radio Service
- 3.2 Single Touch
- 3.2.1 Single Touch Buttons
- 3.2.2 Detailed Single Touch Operation
- 3.2.2.1 Conventional Unit Call
- 3.2.2.2 Conventional Call Alert
- 3.2.2.3 Conventional Status
- 3.2.2.4 Conventional Message
- 3.2.2.5 P25 Unit Call
- 3.2.2.6 P25 Call Alert
- 3.2.2.7 P25 Status
- 3.2.2.8 P25 Interconnect
- 3.2.2.9 SNSZ Unit Call
- 3.2.2.10 SNSZ Call Alert
- 3.2.2.11 SNSZ Status
- 3.2.2.12 SNSZ Message:
- 3.2.2.13 SNSZ Interconnect:
- 3.3 Radio Inhibit
- 3.4 Setting Squelch
- 3.5 Operating Modes
- 3.1 Basic Operation
- Radio Wide Features
- 4.1 Option Buttons
- 4.2 Menu Mode
- 4.3 Time-Out Timer
- 4.4 Home Channel Select
- 4.5 Power Output Select
- 4.6 Alert Tone Select
- 4.7 Ignition Power Down Duration
- 4.8 Horn Alert
- 4.9 Microphone Off-Hook Detect
- 4.10 Surveillance Mode
- 4.11 Public Address
- 4.12 Scanning
- 4.13 Scan Lists
- 4.14 Over the Air Programming
- 4.15 Over the Internet Programming
- 4.16 Auto / Unmute
- 4.17 Location Services
- 4.18 Emergency Alarm Receive Indicator
- 4.19 Kiosk Mode
- 4.20 Analog Noise Reduction
- Conventional Mode Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit / Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Channel Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF / ANI Signaling
- 5.13 Project 25 Mode Features
- 5.13.1 Digital Unit ID
- 5.13.2 Talkgroup ID
- 5.13.3 Network Access Code (NAC)
- 5.13.4 EFJohnson System Out-of-Range Indicator
- 5.13.5 EFJohnson System Automatic Registration
- 5.13.6 P25 Group Calls
- 5.13.7 P25 Unit Calls
- 5.13.8 P25 Conventional Telephone Calls
- 5.13.9 Call Alert
- 5.13.10 Call History
- 5.13.11 Messaging
- 5.13.12 Status Messaging
- 5.13.13 P25 Packet Data
- 5.14 Keypad Programming
- 5.15 Text Messaging
- SMARTNET / SmartZone / P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Unit Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET / SmartZone / P25 Trunking Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 P25 Radio Unit Monitor
- 6.14 SmartZone and P25 Trunking Unique Features
- 6.14.1 Busy Override
- 6.14.2 Site Trunking
- 6.14.3 Determining Current Site and Searching for a New Site
- 6.14.4 Locking / Unlocking a Site
- 6.14.5 Auto Site Search
- 6.14.6 P25 Wide Area Scan
- 6.14.7 Normal P25 and SmartZone Control Channel Hunt
- 6.14.8 Talkgroup Steering through System Access Permissions
- 6.14.9 Radio Information
- 6.14.10 Current Software version in the radio
- 6.15 P25 Trunking System Single Touch
- 6.16 P25 Messaging
- Secure Communication (Encryption)
- Data Features
- Tones & Error Messages
- Service Information
Draft 02 - Sep 1 2015
Viking Mobile Radio Operating Manual 6-3
SMARTNET / SmartZone / P25 Trunked Features
3 Press the PTT switch and begin talking. An optional talk permit tone may sound to
indicate when talking can begin. Other indications that may occur are as follows:
- If in the secure mode and your radio is not programmed with the proper encryption
key, “KEYFAIL” is displayed and the call must be made in the clear mode or the
proper key must be programmed.
- If the busy tone sounds and “BUSY” is displayed, the system is busy. Release the
PTT switch and wait for the call back tone to sound. Then press the PTT switch
within three seconds.
- If a continuous tone sounds and “OUT OF RANGE” is displayed, you may be out of
range of the site or blocked from it by radio-shielding structures or objects. Drive
away from shielding structures or objects and try again. If this does not work, drive
closer to the site.
- If your unit ID is denied, the call is being made to an invalid group ID, or group calls
are not enabled, “Denied” is displayed and an alert tone sounds.
- If an attempt is made to change a channel from the clear to the secure mode and there
is no available secure channel, “CLEAR ONLY” is flashed, an error tone sounds, and
the call is terminated. (SmartNet Only)
- If the Secure mode is selected by the Clear/Secure option switch, soft button
(Lightning Control Head only) or menu parameter and an attempt is made to transmit
on a channel strapped as Clear, “CLEAR ONLY” is displayed and the transmitter is
disabled. Likewise, if the Clear mode is selected and the channel is strapped as
secure, “SECR ONLY” (Standard Control Head) or “Secure Only” (Lightning
Control Head) is displayed and the transmitter is disabled.
6.3.2 Receiving a Standard Group Call
Calls are received on only the talkgroup and/or announcement group programmed for the
selected channel (with scanning disabled).
When a group call is received, the alias of the selected channel is displayed. The radio can
be programmed so that the following are also displayed for 0.5-7.0 seconds or
continuously during the call.
PTT ID - The unit ID of the mobile placing the call is displayed.
TG on Rx - The alias of the talkgroup on which the call is being received is displayed
(typically for use by technicians).
User Group ID - If the group ID of the call being received is included in a
preprogrammed User Group ID list, the alias programmed in that list for that group is
displayed.
Receive Key ID - The Key ID (or the alias, if programmed) of the key used to decode
the call is displayed.