Installation Sheet

SensoWash_MAL_WWC_US_57045/17.03.3
Electrical installation
Position of electrical / water connection
Pre-Installation
> Lay a permanent power supply line:
 Please observe the position of the electrical
connection
 Leave at least 31 ½“ of feed cable exposed
> Install circuit breaker
 Connect a separate upstream circuit breaker
 Connect an upstream residual current device (RCD)
separating all poles
> Appliances have to be correctly earthed.
24
Connecting the cable (Diagram 24)
>Please observe the L, N and PE conductors.
26
Installing junction box (Diagram 26)
> Fix the junction box in the Wall-mounted WC in
the designated place.
Water installation
Power supply
6. . . . . . . 1 . . . . . . 100 - 120 V 50/60 Hz
Max. rated power 1.65 kW
Circuit breaker I
N
= 16 A
RCCB I
N
= 30 mA
Protection type IP X4
Protection class 1
Cold water DN 15(½")
Water pressure 10 - 109 psi
(0.07 0.75 MPa)
Water hardness max. 2,4 mmol/l
NOTE!
> Install a water water softener with water
hardness 2.4 mmol/l
( 14° dH and/or 24° fH).
Pre-Installation
>Install the water connection and water outlet in the
specified areas.
DANGER!
Health risk and potential product damage.
> Supply the Shower WC with cold drinking water from
the main water system.
>Do not connect any waste water, grey water, industrial
water, sea water or other untreated or semi-treated
water.
11
Connecting the water (Diagram 11)
NOTE! Avoiding any malfunctions!
>Only use the water supply hoses provided.
55
2
1/8”
3
1/2”
5
3/8”
3
7/8”
3
1/2”
7
1/8”
90 90
IG 1/2”
100
180
135
5