DirectVent Pro® Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.
Specifications Applications DirectVent Pro is a unitized, coaxial (concentric) venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. Materials and Construction .020” aluminum inner wall. .018” galvanized steel outer wall. Painted outer walls made of laserwelded .018” galvalume steel. Caps also available in stainless steel and copper. Outer pipe brings combustion air to the appliance. Inner pipe exhausts flue gases to the outside.
Direct Vent | DirectVent Pro Installation Key Typical Installations 1 15 1 15 2 3 8 4 5 15 5 1 Vertical Termination Cap 9 90° Elbow 2 Storm Collar 10 Horizontal Termination Cap 3 Flashing 11 Snorkel Termination Cap 4 Cathedral Ceiling Support Box 12 Colinear Kit 5 Pipe 13 3” Flex 6 45° Elbow 14 Co-Axial to Co-Linear Connector 7 Class A Chimney Conversion Kit 15 Masonry Chimney Conversion Kit 8 4” Flex 16 Elbow Strap 9 5 5 15 • Refer to our Typical Venting Installat
DirectVent Pro | Direct Vent Planning Your Installation Design Recommenation 185 DuraVent | www.duravent.com 1 For vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support/wall thimble cover or a cathedral ceiling support box. 2 To determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story.
Direct Vent | DirectVent Pro Minimum Height Vent Termination Chart H X 12” Horizontal Termination Kit A Roof Pitch Feet Meters Flat to 7/12 1 0.30 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4 1.22 Over 12/12 to 14/12 5 1.52 Kit includes: 90° black Elbow, Ceiling Support/Wall Thimble Cover, 24” black Pipe, 8 1⁄2” black Pipe Extension. Termination cap not included. For 4” x 6 5⁄8” direct vent.
DirectVent Pro | Direct Vent Kit 46DVA-KMC includes: Cap Adapter, 18” x 18” Flashing, Round Ceiling Support/Wall Thimble Cover, Retro Connector. For 4” x 6 5⁄8” direct vent. Termination Cap and 4” flex are sold separately. Masonry Chimney Conversion Kit 6ǫ” Kit 46DVA-KCT includes: Cap Adapter and a 18” x 18” Flashing. Use with 4” x 6 5⁄8” direct vent gas stoves. Use existing masonry chimney. Route the exhaust gases and intake air through the side of the masonry chimney.
Direct Vent | DirectVent Pro Designed for appliances tested and listed for direct vent. Features a fully unitized twist-lock construction in both 4” x 6 5⁄8” and 5” x 8” vent sizes. Use of sealant is optional, unless specified by the appliance manufacturer. To calculate install length, subtract 1 1⁄2” for each joint. No beads or hems. Black pipe lengths feature exterior laser-welded seams.
DirectVent Pro | Direct Vent Use to add length to a straight length of DirectVent Pro.
Direct Vent | DirectVent Pro Use to offset obstructions as needed. Fully unitized, twist-lock construction. Elbows swivel, allowing the lock to remain fully engaged while aligning to the desired direction. The angle will remain fixed at 90°. 90° Elbow SIZE A B 4” x 6 5⁄8” 5” x 8” GALVANIZED ORDER # 46DVA-E90 58DVA-E90 STOCK # 810001311 810001395 BLACK ORDER # STOCK # 46DVA-E90B 810001312 58DVA-E90B 810001396 A B 6 1⁄2” 7 3⁄8” 6 1⁄2” 7 3⁄8” Use for supporting vent pipe between offsets.
DirectVent Pro | Direct Vent Provides a complete wall-pass-through and firestop. Use with Square Horizontal Cap only. May be required in Canada. Refer to the appliance manufacturer’s installation instructions for requirements. Wall Thimble 4” 4” SIZE 4” x 6 5⁄8” A C 5” x 8” ORDER # 46DVA-WT 58DVA-WT STOCK # A B C 810001316 810001400 6 3⁄4” 8 1⁄4” 11” 12 1⁄2” 12” 12 1⁄2” B Provides a complete wall-pass-through and firestop. Use with Round Horizontal Cap and Sconce Cap only.
Direct Vent | DirectVent Pro Use as a heat shield on structures with vinyl siding, or other temperature sensitive materials, to help prevent warping and or melting of the material. Use only on horizontal terminations and on any irregular surfaced siding (ie: ship lap siding, shake shingle siding) so cap is not imbedded in the siding. Sized for Square Horizontal Cap.
DirectVent Pro | Direct Vent Prevents water intrusion into stucco-sided homes. Allows the installer to apply siding material (ie: stucco, brick, etc) over the flanges up to the sides of the flashing for a water-tight seal. Kit includes 4-pieces; sized for Square Horizontal Cap only.
Direct Vent | DirectVent Pro Use to support vent pipe. Provides 1” clearance. Recommend installing Wall Straps at 4-foot intervals on vertical runs. Wall Strap 1” A SIZE 4” x 6 5⁄8” 5” x 8” ORDER # 46DVA-WS 58DVA-WS STOCK # A 810001330 810001410 6 5⁄8” 8” Use only in accordance with specific appliance manufacturer’s installation instructions to restrict incoming combustion air.
DirectVent Pro | Direct Vent Dead Soft Aluminum Flashings A Use with metal or tile roofs. Available in sizes 4”x 6 5⁄8” and 5”x 8”, in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of malleable dead soft aluminum. Refer to roof flashings tables (previous page) for dimensions.
Direct Vent | DirectVent Pro Use for horizontal through-the-wall terminations. Check installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. Available in aluminum, stainless steel (S), and copper (C). Check with appliance manufacturer for approval. Patented.
DirectVent Pro | Direct Vent Use for horizontal through-the-wall terminations when a vertical rise is desired in the system to meet appliance manufacturer recommended minimum heights. Do not enclose in the wall or install below grade.
Direct Vent | DirectVent Pro Low-Profile Termination Cap D C A Use for vertical terminations only. Check the appliance manufacturer’s instructions to determine which caps are approved for use with their appliance. Available in aluminum and stainless steel (S).
DirectVent Pro | Direct Vent Use Co-Linear Adapter for stoves with 4” X 6 5⁄8” co-axial outlets. Refer to appliance manufacturer’s installation instructions for approval. Uses 3” aluminum flex for both intake and exhaust.
Direct Vent | DirectVent Pro Reducer Use to reduce vent diameter. Check with appliance manufacturer for approval. *updated illustration* SIZE 3 3/8” REDUCE TO ORDER # STOCK # 58DVA-J 68DVS-X58 810001436 810006145 5” X 8" 4” x 6 5⁄8” 6” X 8 5⁄8” 5” X 8” 7 1/8" 3 ¾" Co-Linear Flex Connector Use as a flex connector with inserts with 3“ co-linear intake and exhaust ports.
DirectVent Pro | Direct Vent SIZE Elbow Chimney Degrees Section Offset Chart RISE OFFSET 201 DuraVent | www.duravent.